ViewSonic EXES-2000 - Manual

ViewSonic EXES-2000

ViewSonic EXES-2000 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
Page: / 44

Table of Contents:

  • Page 2 – BEFORE READING THIS HAND BOOK
  • Page 3 – Part 1. Outlines of EXES-2000 system and related equipment; Description and features; Notes
  • Page 4 – Pager control unit PC20:; exchange, and a circuit for transmitting voice signals.
  • Page 5 – Part 2. Installation of EXES-2000 system; Installing and adjusting procedures; Observe the following precautions in installing each equipment:; splashed by rain water.; (E) Areas close to high voltage equipment or where strong electric; Installation of equipment; -1 Selection of the place to install
  • Page 6 – -2 Installation of the exchange; Follow the procedures below to install the EX-200 exchange:; Dimensions
  • Page 7 – Note; there is a limit to spacing between the two units. You; Fit bracket receptacles of the FC-210 into the
  • Page 8 – Follow the procedures below to install the PU-200:; Remove 4 case fixing screws and fit the attached; -4 Installation of PU-200 power supply unit
  • Page 9 – -5 Installation of Stations; Mount switch box and make piping and wiring arrangements; before the station jack is installed.; holes provided on the top and the bottom of the case or a cable; Other stations; Please refer to instruction manual of each station.
  • Page 10 – Cable installation
  • Page 11 – Connection of equipment; -1 Addition of LM unit
  • Page 14 – Cut a jumper wire to connect each input.
  • Page 15 – -6 RC unit connection; P1 (Audio signal output for paging zone 1)
  • Page 16 – -7 PC unit connection; SERIAL OUTPUT (serial data output for pager control); Serial data output
  • Page 17 – Dotted lines stand for wiring when two exchanges are connected.; -8 Tl unit connection; for
  • Page 18 – -9 SM unit number setting
  • Page 19 – -10 Connection for speaker station; Resistor to cut
  • Page 20 – -11 Connection of power source; board with the attached connection cable.; Select the desired voltage by means of
  • Page 22 – LIST OF FUNCTION AVAILABLE FROM EXES-2000 SYSTEM; cation; Transfer
  • Page 24 – HIGHEST EXECUTIVE PRIORITY
  • Page 25 – CONTINUOUS CALLING TONE
  • Page 26 – STATIONS ALLOWED ACCESS TO PAGING
  • Page 28 – HANDSET STATION REGISTRATION
  • Page 30 – STATIONS ALLOWED ACCESS TO SPEECH MESSAGE
  • Page 31 – DOOR SUBSTATION REGISTRATION
  • Page 32 – SECRETARY TRANSFER
  • Page 34 – REGISTRATION OF STATIONS TO REFUSE ALL-CALL PAGING
  • Page 35 – REGISTRATION OF STATION TO REFUSE ZONE 1 PAGING
  • Page 36 – REGISTRATION OF STATIONS TO REFUSE ZONE 2 PAGING
  • Page 37 – REGISTRATION OF STATIONS TO REFUSE ZONE 3 PAGING
  • Page 40 – Trouble-shooting at the time of installation; Cannot dial
  • Page 41 – Paging is impossible.
  • Page 42 – FUNCTION TABLE FOR STATIONS; Function Table for Stations
  • Page 43 – STATION DATA TABLE; Station Data Table
Loading the manual

EXES-2000

EX-200

For

EXES-2000 INTERCOM SYSTEM

Fully Electronic Exchange

INSTALLATION HAND BOOK

TOA Corporation

KOBE, JAPAN

EX-200

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - BEFORE READING THIS HAND BOOK

This hand book forms part of installation manual for TOA EXES-2000 intercom system. Various functions and external equipment other than normal speech may be employed in the TOA EXES-2000 intercom system according to changing users' needs. To make such additional functions available, however, functio...

Page 3 - Part 1. Outlines of EXES-2000 system and related equipment; Description and features; Notes

Part 1. Outlines of EXES-2000 system and related equipment 1. Description and features The Toa EXES-2000 is a fully electronic intercom system, and has the following f e a t u r e s : Wall mounted exchange. Easy system expansion and addition of functions thanks to the modular concept employed in the...

Page 4 - Pager control unit PC20:; exchange, and a circuit for transmitting voice signals.

Central control unit CC-20: This unit is comprised of a CPU that processes the exchange procedures, a speech link consisting of a voice switch circuit and a signal tone generating circuit, and a power circuit. Line modem unit LM-20: This unit is comprised of a circuit for sending out signals from th...

Other ViewSonic Models

All ViewSonic Other