Vector VEC1043 - Manual
Vector VEC1043 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – IMPORTANT SAFETY INSTRUCTIONS; Read This User’s Manual Before Using This Power Inverter.; SAVE THESE INSTRUCTIONS
- Page 3 – TABLE OF CONTENTS; INTRODUCTION; Your new; VEC1043 750 Watt Power Inverter Vehicle Power System; is one; CONTROLS, INDICATORS AND CONNECTORS; Figure 1; Figure 1 Front Panel; Figure 2; Figure 2 Back Panel; Figure 3
- Page 4 – Modified Sine Wave and Sine Wave Comparison; PROTECTIVE FEATURES OF THE INVERTER; This condition is not harmful to the inverter, but could damage; Over Voltage Protection —; The Power Inverter will automatically shutdown when the; Overload Protection —; The unit will automatically shut down when the continuous; Over Temperature Protection —; If the temperature inside the Power Inverter reaches; INSTALLATION AND OPERATING INSTRUCTIONS; Power Source Requirements; Figure 3 Top Panel; HOW THIS INVERTER WORKS; Principle of Operation
- Page 5 – Connecting to a Power Source Using the Provided Cables; are present in the installation area.; Direct Hardwiring to Power Source; Insert a fuse appropriate to the inverter in the fuse holder.
- Page 6 – CARE AND MAINTENANCE; excessive humidity or dampness.; TROUBLESHOOTING; “Buzzing” sound in audio systems; minimize interference.; Rated Versus Actual Current Draw of Equipment
750 Watt
Power Inverter
Vehicle Power System
Converts DC Vehicle Power
to 115 Volt AC Household Power
VEC1043
USER’S MANUAL
& WARRANTY INFORMATION
IIIIM
M
M
MPPPPO
O
O
ORRRRTTTTA
A
A
AN
N
N
NTTTT SSSSA
A
A
AFFFFEEEETTTTYY
Y
Y IIIIN
N
N
NFFFFO
O
O
ORRRRM
M
M
MA
A
A
ATTTTIIIIO
O
O
ON
N
N
N,,,, SSSSA
A
A
AV
V
V
VEEEE TTTTHHHHEEEESSSSEEEE IIIIN
N
N
NSSSSTTTTRRRRUUUUC
C
C
CTTTTIIIIO
O
O
ON
N
N
NSSSS
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND
THIS INSTRUCTIONAL MANUAL. THIS MANUAL CONTAINS IMPORTANT
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.
www.vectormfg.com
4140 S.W. 30th Ave., Ft. Lauderdale, FL 33312
Toll Free: (866) 584-5504
8
Fault Protection Code and Troubleshooting Guide
INVERTER POWER SWITCH TURNED ON
SPECIFICATIONS
Output Connection:
North American standard outlet
Output Voltage:
Approx. 115 volts AC, RMS 60 Hz
Output Current:
6.5 amps Max
Output Waveform:
Modified Sine Wave
Input Voltage:
12.5 volts DC
Low Voltage Alarm:
11.0 volts DC
No Load Input Current: 0.7 amps max.
Input Fuses:
Internal
Input Cables:
Battery clip cables
Additional Protection:
Overload, overvoltage, overheating
Trouble/Indication
Possible Cause
Suggested Remedy
No AC output — yellow
LED lit
DC input is below
10 volts
Recharge or replace the
battery.
No AC output — red LED
lit
Excessive appliance
load
Reset unit by turning OFF,
then back ON.
Inverter hot
Disconnect load from
inverter. Operate inverter
without load for a few
minutes. Reconnect load.
No AC output — green
LED not lit
Bad connection or
wiring
Tighten all DC connections.
Low battery alarm sounds
Low battery voltage
Recharge battery. Remove
load from inverter while
recharging battery.
Motorized power tool will
not operate
Excessive start-up load If appliance does not start,
appliance is drawing too
much voltage and will not
work with this inverter.
Motorized power tool
does not operate at
correct speed
Purely inductive load
Make the load not purely
inductive (i.e., operate an
incandescent lamp at the
same time as power tool).
Television/radio
interference
Snow in picture,
“buzzing” sound
Keep inverter and antenna
distant from each other.
Use shielded antenna.
Connect antenna to
amplifier.
VEC1043_ManualEN_091505 1/17/06 5:49 PM Page 8
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
ii iii IMPORTANT SAFETY INSTRUCTIONS WARNINGSTO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, EXPLOSION OR INJURY:• Do not connect to AC distribution wiring.• Remove appliance plug from outlet strip or turn off inverter before working on the appliance. Multiple outlet power strips with switches and circu...
iv TABLE OF CONTENTS Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1Controls, Indicators and Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1How This Inverter Works . . . . . . . . . . . . . . . . . ...
3 not read the RMS voltage of a modified sine wave correctly. They will read about 20to 30 volts low when measuring the output of the inverter. For accurate measurementof the output voltage of this unit, use a true RMS reading voltmeter such as a Fluke179, Fluke 79 III series, Beckman 4410, or Tripl...