Page 2 - Tips for First-Time Use; Do not pierce or burn refrigerant lines or any other components.
[email protected] www.turbro.com Tips for First-Time Use 1 . Allow the unit to sit upright for at least 3-4 hours before powering on. Shipping carriers may set the unit on its side, which causes the refrigerant to pool in certain areas. Standing the unit upright for 3-4 hours allows the refrigerant ...
Page 3 - CONTENTS
[email protected] www.turbro.com CONTENTS Warranty Information ················································································································36 Customer Support SAFETY INFORMATION·······················································································...
Page 4 - SAFETY INFORMATION; Installation and Setup
[email protected] www.turbro.com SAFETY INFORMATION 01 Please read all instructions before use and save this user manual for future reference. A digital version can be obtained from Customer Support. Your safety and the safety of others are very important to us. We have provided many important safet...
Page 6 - Indoor Unit; PARTS DESCRIPTION; Current status
[email protected] www.turbro.com 03 Indoor Unit NOTE: When the remote controller fails, press the Manual Button with insulation material. PARTS DESCRIPTION 07 01 Air Filter 04 Electric Control Box 07 Air Outlet 08 02 Air Inlet 05 Manual Button 08 Deflector 03 USB Module (Inside) 06 Front Panel 01 02...
Page 7 - Display; Indicator for Timer Function.; Outdoor Unit; Air Outlet
[email protected] www.turbro.com 04 Display 01 02 Indicator for Timer, Temperature, and Error codes. Indicator for Timer Function. Indicator for Sleep Mode. 01 02 03 03 Outdoor Unit 01 01 02 03 04 Air Outlet Air Inlet Wiring Box Valve Box 02 03 04
Page 9 - INSTALLATION INSTRUCTIONS; Tools Prepared for Installation
[email protected] www.turbro.com 06 PARTS PARTS NAME QUANTITY Drain hose Sealing gum 1 Insulation tape 1 Rubber feet for outdoor unit 4 Guide plate 1 2 INSTALLATION INSTRUCTIONS Bubble Level Screwdriver Pencil Scissors Universal Meter Measuring tape Drill with Hole Saw Electric Drill Electroprobe To...
Page 10 - Ceiling
[email protected] www.turbro.com 07 Before installing the indoor unit, you need to check the label on the product box and make sure that the model number of the indoor unit matches the model number of the outdoor unit. Step 1: Select the Installation Location Check the location meets the following r...
Page 12 - Step 4: Connecting Refrigerant Pipe; YES
● There is a small amount of refrigerant in the pipe for testing before it leaves the factory. When unscrewing the screw cap of the refrigerant pipe, there will be a sound to indicate the refrigerant has not leaked during transportation. If there is no sound, the pipe may be broken, please check for...
Page 14 - Step 6: Connect Signal Cable; Outdoor unit
[email protected] www.turbro.com 11 Control box cover Wiring diagram ĂďůĞĐůĂŵƉ Step 6: Connect Signal Cable ● Choose the correct cable size determined by the maximum operating current on the rating label and table below. ● Open the front panel of the indoor unit. Use a screwdriver to open the electr...
Page 15 - Step 8: Mount Indoor Unit
[email protected] www.turbro.com Step 7: Wrap Piping and Cable ● Arrange the pipes, cables, and drainage hose as shown in the following picture. ● 12 Use the insulation tape to wrap them together as a bundle tightly. hose. Continue wrapping together and leave a few inches of the signal cable and ref...
Page 16 - Outdoor Unit Installation
[email protected] www.turbro.com ● Reserve the spaces as shown in the picture for the air to circulate. ● Install the outdoor unit in a safe and solid place. ● Do not install the outdoor unit near sources of heat, steam, or flammable gas. ● Do not install the unit in windy or dusty places. ● Do not ...
Page 17 - Step 3: Fix Outdoor Unit
[email protected] www.turbro.com 14 /ŶƐƚĂůůϰƌƵďďĞƌĨĞĞƚ;ŽƉƟŽŶĂůͿ Terminal block ĂďůĞĐůĂŵƉ Wiring cover Wiring diagram Step 3: Fix Outdoor Unit ● Mark the installation position for expansion bolts. Drill holes and place the bolts. ● Optional step: install 4 rubber feet on the hole before placing the o...
Page 18 - POWER; Indoor unit; POWER SUPPLY; Due to different production batches,
[email protected] www.turbro.com ● According to the wiring diagram pasted inside the wiring cover or the picture below, connect the signal 15 and power cables to the corresponding terminals. Ensure all connections are firm and secure. ● Reinstall the cable clamp and wiring cover. NOTE: ● When connec...
Page 19 - Newton meter
[email protected] www.turbro.com Step 5: Connect Refrigerant Pipe ● Unscrew the valve cover and press it down gently. ● 16 Remove the protective caps from the end of the valves. Take off the plastic cover in the pipe ports. ● After aligning the refrigerant pipes, rotate the flare nut of the refriger...
Page 21 - Flare pipe ends
[email protected] www.turbro.com Ӧ Flare pipe ends ● 18 After removing burrs from the cut pipe, seal the ends with tape to prevent foreign materials from entering the pipe. ● Sheath the pipe with insulating material. ● Place flare nuts on both ends of the pipe. Make sure they are facing in the right...
Page 24 - Inspection Before Use; OPERATING INSTRUCTIONS; Operating from the App
[email protected] www.turbro.com Electrical safety inspection ● Check whether the power supply voltage complies with that on the rating label. ● 21 Check whether there is any wrong or missing connection between the power cables, signal cables, and earth cables. ● Check whether the earth resistance a...
Page 26 - EZ Mode
[email protected] www.turbro.com 23 EZ Mode Press the "display" button on the controller for 6 times in 8 seconds to switch on WiFi function. The indoor unit displays "CF".Enter Wi-Fi password and choose “EZ Mode” (default).When the app instruction asks to reset the device by pressin...
Page 28 - Voice Control; Alexa and Google Voice Command; Operating from the Remote Control
[email protected] www.turbro.com 25 NOTE: ● The APP is only compatible with smartphones and is not available for laptops or tablets. ● APP may not support the latest version of Android or iOS system because of the test of stability. Also may not be compatible with tampered Android or iOS system. ● D...
Page 30 - Function Description; AUTO
[email protected] www.turbro.com Ӧ AUTO MODE The unit will automatically switch between Cool/Heat or Fan Mode depending on the ambient room temperature. ● Press the “MODE” button until the symbol appears on the remote screen. ● Pressing the "FAN" button will adjust the fan speed. Ӧ COOL MODE...
Page 33 - Other Functions
[email protected] www.turbro.com ● Press the timer button again, the timer will be canceled and the will disappear. ECO Button In this mode the set temperature will be limited to 79°F-88°F(26°C-31°C) in COOL mode and 61°F-77°F(16°C-25°C) in HEAT mode to save energy. ● Press the “ECO” button to activ...
Page 35 - CLEANING; Warning
[email protected] www.turbro.com 32 CLEANING Warning ● When cleaning, you must shut down the machine and cut off the power supply for more than 5 minutes. ● Under no circumstances should the air conditioner be flushed with water. ● Volatile liquid (e.g. thinner or gasoline) will damage the air condi...
Page 36 - Maintenance Checklists; Pre-Season Maintenance Checklist
[email protected] www.turbro.com ● 33 Clean the filter with soapy water and air dry it. ● When installing the filter, first insert the lower end into the corresponding position of the unit, and then squeeze the upper end of the filter into the corresponding buckling position of the unit body. NOTE: ...
Page 39 - WARRANTY & CUSTOMER SUPPORT; WARRANTY; said defect is confirmed by the manufacturer's inspection.; We are here to help anytime!
WARRANTY & CUSTOMER SUPPORT [email protected] www.turbro.com 36 WARRANTY CUSTOMER SUPPORT TURBRO provides a 5-year limited warranty for TURBRO products from the date of purchase, subject to the following conditions and limitations outlined below. What is covered? ● This warranty is limited to re...