Trane UD1B080A9H31B - Manual

Trane UD1B080A9H31B

Trane UD1B080A9H31B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
Page: / 24

Table of Contents:

  • Page 2 – Installer’s Guide; SAFETY SECTION; As far as practical, close all building doors and windows; WARNING
  • Page 3 – Installation Instructions; Outline Drawing; Start Up and Adjustment; Contents; and; indicates a potentially hazardous situa-; CAUTION; indicates a potentially hazardous situation; CAUTION; o prevent shortening its service life, the furnace
  • Page 4 – LOCATION AND CLEARANCES; GENERAL INSTALLATION INSTRUCTIONS
  • Page 5 – LINE DRA
  • Page 7 – UPFLOW INSTALLATION; DOWNFLOW INSTALLATION; SEE FIGURE 3 AND TABLE 1; TABLE 1; HORIZONTAL INSTALLATION; the cased coil must be properly supported. The; FOR VERTICAL; FURNACE; CASED COIL CONNECTION
  • Page 8 – AIR FOR COMBUSTION AND VENTILATION; TYPICAL ATTIC PLATFORM INSTALLATION; UNCONFINED; MENT INSTALLED
  • Page 9 – All air from inside the building as in Figure 9: The; require; use of; MINIMUM AREA IN SQUARE FEET FOR; FURNACE MAXIMUM; TABLE 3; MINIMUM FREE AREA IN SQUARE INCHES
  • Page 10 – DUCT CONNECTIONS; The side panels of the upflow furnace include; Determine the appropriate postion to set the
  • Page 11 – Brackets are factory sup-; FRONT; CUT OUT; BOTTOM FILTER RACK INSTALLATION; Airf low; The bottom panel of the upflow furnace must be; RETURN AIR FILTERS
  • Page 12 – TABLE 4; Typical Upflow Left Side Return Filter Rack Installation; Typical Upflow Right Side Return Filter Rack Installation; Airflow; Typical Horizontal Filter Installation
  • Page 13 – Bottom Panel; Furnace
  • Page 14 – TABLE 5; GENERAL VENTING INSTRUCTIONS
  • Page 15 – TABLE 7; MASONRY CHIMNEY VENTING; External Masonry Chimney; When vent connections must pass through walls or; VENT PIPING; VENTING INTO A MASONRY CHIMNEY; to allow venting into a ma-; INTERNAL MASONRY CHIMNEYS
  • Page 16 – TABLE 8; πππππ; Where long periods of airflow are desired for com-; GAS VENT TERMINATION; ELECTRICAL CONNECTIONS; 0 – “latest edition” and Canadian Electrical
  • Page 17 – FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE; FIELD WIRING DIAGRAM FOR 1 STAGE FURNACE
  • Page 18 – TWINNING
  • Page 19 – GAS PIPING; DO NOT CHECK WITH AN OPEN FLAME!; TOP VIEW OF RIGHT SIDE PIPING
  • Page 20 – START-UP AND ADJUSTMENT; PRELIMINARY INSPECTIONS
  • Page 21 – TABLE 9; ORIFICE SIZES; PART NUMBERS FOR REPLACEMENT ORIFICES; HIGH ALTITUDE DERATE; Installation of this fur-; The manufacturer of your furnace does NOT test
  • Page 22 – LIGHTING INSTRUCTIONS; TO SHUT OFF; FLOW; White-Rodgers 36G gas valve; ff Swi
  • Page 23 – This product contains fiberglass wool insulation!; OPERATING INFORMATION; EXCESSIVE COMBUSTION VENT PRESSURE OR; must be checked out on initial
  • Page 24 – INTEGRATED FURNACE CONTROL ERROR FLASH CODES; LOSS OF FLAME OR GAS SUPPLY FAILURE
Loading the manual

*Horizontal Conversion for these furnaces may be left or right side rotation.

*UD1A040A9H21B
*UD1B060A9H31B
*UD1B080A9H31B
*UD1C080A9H41B

High Efficiency Single Stage Upflow/ Horizontal
and Downflow/ Horizontal Gas-Fired Furnaces,
“Fan Assisted Combustion System”

ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES

IMPORTANT —

This Document is

customer property

and is to remain with this unit.

Please return to service information pack upon completion of work.

Installer’s Guide

*UD1B100A9H31B
*UD1C100A9H51B
*UD1D120A9H51B
*UD1D140A9H51B

*DD1B060A9H31B
*DD1B080A9H31B
*DD1C100A9H51B
*DD1D120A9H51B

*__First letter may be “A” or “T”

Upflow/ Horizontal*

Downflow/ Horizontal*

A341789P07

1 8 - C D 2 1 D 1 - 5

For VENT SIZING INFORMATION see:

USA

National Fuel Gas Code ............. ANSI Z223.1/NFPA 54 (latest version)

CANADA

Natural Gas Installation Code ........... CAN/CGA-B149.1 (latest version)
Propane Installation Code ................. CAN/CGA-B149.2 (latest version)

USA/CANADA ALTERNATE —

Category I Venting Guide .................................. Pub. No. 18-CH23D1-2

*UD1-H

*DD1-H

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installer’s Guide; SAFETY SECTION; As far as practical, close all building doors and windows; WARNING

© 2008 Trane All Rights Reserved 18-CD21D1-5 Installer’s Guide The following safety practices and precautions must befollowed during the installation, servicing, and opera-tion of this furnace. 1. Use only with the type of gas approved for this fur- nace. Refer to the furnace rating plate. 2. Instal...

Page 3 - Installation Instructions; Outline Drawing; Start Up and Adjustment; Contents; and; indicates a potentially hazardous situa-; CAUTION; indicates a potentially hazardous situation; CAUTION; o prevent shortening its service life, the furnace

Installer’s Guide 18-CD21D1-5 3 Installation Instructions 3 General Installation Instructions 4 Location and Clearances 4 Outline Drawing 5 Upflow Installation 7 Downflow Installation 7 Air For Combustion and Ventilation 8 Duct Connections 1 0 Return Air Filters 1 1 Typical Upflow Return Air Filter ...

Page 4 - LOCATION AND CLEARANCES; GENERAL INSTALLATION INSTRUCTIONS

4 18-CD21D1-5 Installer’s Guide LOCATION AND CLEARANCES The location of the furnace is normally selected by thearchitect, the builder, or the installer. However, beforethe furnace is moved into place, be sure to consider thefollowing requirements: 1. Is the location selected as near the chimney or v...

Other Trane Models