Trane TWA200B - Manual

Trane TWA200B

Trane TWA200B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
Page: / 56

Table of Contents:

  • Page 2 – Introduction; Manufacturing Control
  • Page 3 – Contents; Model Number Description
  • Page 4 – Condensing Units Options; Low Ambient Cooling Operation; Head Pressure Control
  • Page 7 – Air Delivery Selection
  • Page 8 – TWE = Cooling Convertible
  • Page 9 – Table GD-1 — General Data — Heat Pumps
  • Page 10 – General Data — Heat Pumps
  • Page 24 – Table PD-14 — Blower Speeds — TWE050A
  • Page 25 – Table PD-16 — Blower Speeds — TWE075A; Table PD-15— Continued
  • Page 26 – Table PD-17— Continued
  • Page 27 – Table PD-20— Blower Speeds — TWE155B
  • Page 29 – — Air Handler
  • Page 30 – Table PD-25 — Auxiliary Electric Heat Capacity — Air Handler
  • Page 34 – Heat Pump — Single Compressor
  • Page 36 – Heat Pump — Dual Compressors
  • Page 38 – Air Handler
  • Page 39 – Figure DD-1 — TWA075 Heat Pump; All dimensions are in inches and millimeters.
  • Page 41 – Figure DD-3 — TWA155B Heat Pump
  • Page 42 – Figure DD-4 — TWA200B Heat Pump
  • Page 43 – Figure DD-5 — TWE050A Air Handlers
  • Page 44 – Figure DD-6 — TWE075A Air Handler
  • Page 45 – Figure DD-7— TWE100A Air Handler
  • Page 46 – Figure DD-8— TWE100B Air Handler
  • Page 48 – Figure DD-10— TWE155B Air Handler
  • Page 49 – Figure DD-11 — TWE200B Air Handler
  • Page 51 – Figure DD-14 — Electric Heater for TWE155 and 200 Air Handlers
  • Page 52 – Heat Pumps; Controls; This
  • Page 53 – Air Handlers
Loading the manual

Split System Heat Pumps

Split System Heat Pumps
TWA075A-TWA200B
Air Handlers
TWE050A-TWE200B
50 Hz

SSP-PRC002-EN

January

2004

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Introduction; Manufacturing Control

©American Standard Inc. 2001 SSP-PRC002-EN Introduction Split System Heat Pump Units . . .Designed With Your Needs In Mind. The Trane reputation for quality andreliability in air conditioning continueswith the Odyssey™ family of lightcommercial split systems. Trane paidattention to your needs to mak...

Page 3 - Contents; Model Number Description

Contents SSP-PRC002-EN 2 4 6 7 8 9 12 12 2431 33 39 52 Introduction Features and Benefits Application Considerations Selection Procedure Model Number Description General Data Performance Data Cool and Heat PerformanceFan Performance Electric Power Connection and Wiring Dimension and Weights Mechanic...

Page 4 - Condensing Units Options; Low Ambient Cooling Operation; Head Pressure Control

4 SSP-PRC002-EN Features andBenefits Condensing Units Options The TWA075A and 100A singlecompressor models feature singlerefrigeration circuitry, lowering jobinstallation costs by requiring only oneset of refrigerant lines. These units areideal for the low cost, new constructionjobs as well as renov...

Other Trane Models