  • Page 3 – Low Battery Warning; BIND; Celsius/Fahrenheit Jumper; Network
  • Page 4 – Part Two: Installing Guide; Replacement installations; – Location of Thermostat; Tools Needed; Read instructions carefully before remov-; Do not turn electricity back on until work is completed.; WARNING–Risk of Fire or Electric Shock; Do not short (jumper) across electric terminals at control on
  • Page 5 – Separate front from back of; Terminal; Control unit; Do not allow wires to touch each other; Before You Connect Wires; Which wires do you have?; Determine which step-by-step wiring diagram you; J u m p e r s; If you are mounting the
  • Page 6 – C W RH; Wire; C B O W2 W; Your system is now connected. Continue on page 9.; W RH A; Wire; C B; Wire Zoned
  • Page 7 – Go To Page 9; C W RH G; C B O W; Wire; R G; C B O W; Wire; C W Y RH RC G; Wire
  • Page 8 – Wire Heat Pump; DO NOT connect; or; Wire; or; DO NOT connect; stage Cool
  • Page 9 – Replace the batteries when; – Install AA Batteries; AA; Congratulations, you have successfully; (If you connected the G wire – fan relay)
  • Page 10 – Power Requirement; Calibrate; Wire Reference Guide; DO NOT CONNECT B to B; Lennox Heat Pump; wire Zoned Hot Water
  • Page 11 – Jumper Reference; LIMITED ONE-YEAR WARRANTY
Loading the manual

Installation and User Instructions

MODEL CA8900 Z-Wave

®

Digital Thermostat

The CA8900 is a digital thermostat that can be con-

trolled wirelessly with Z-Wave controllers supporting
the Thermostat General V2 Device Class. The thermo-
stat is compatible with all standard 24 VAC heating
and cooling systems, up to two-stage heat, one-stage
cool, and two-stage heat pump. The CA8900 operates
as a simple thermostat with buttons to set target tem-
peratures for heat and cool modes. The Save Energy
button adds two more modes for target temperatures
to provide a single button set-back mode for easy op-
eration. It can easily be retrofitted to existing systems
as part of a Z-wave control strategy.

The CA8900 Wireless Thermostat provides two-way

communication as part of a Z-Wave

®

network. When

it receives commands from the Central Controller
Unit, it sends back confirmation that the command
was received and imple-
mented. Each module in a
Z-Wave network communi-
cates with every other mod-
ule, acting as a “repeater”
and routing your commands
to their destination by the most reliable pathway.
When Z-Wave devices (regardless of manufacturer)
are installed throughout the house, signals are au-
tomatically routed around obstacles or dead spots,
strengthening the network as more devices are added.
The Z-Wave icon shows on the lower right of the dis-
play panel, indicating that the thermostat is in contact
with the controller. If the icon is not present, commu-
nication has been lost. If this occurs, all remote HVAC
functions are shut off.

Description and Features

This guide is in two parts:

Part One: Operating Guide

for the homeowner or end user.

Part Two Installing Guide

for the installer or technician.

This thermostat can be used with all 24VAC heat-

ing and cooling systems. It cannot be used with line
voltage systems.
The CA8900 is digital and your desired heat or cool

temperatures can easily be set on the large screen
with the

TEMP UP (+)

and

TEMP DOWN (-)

buttons

on the front.
A minimum 4-minute off time protects heating and

cooling systems from damage.
This thermostat uses a new technique called sequen-

tial staging for more comfort with faster reaction to
requested temperature changes.

NOTE:

When using a heat pump with auxiliary

heat, if the heat pump cannot keep up and/or is
defective, remove jumper from position 2B and put
jumper on position 2A. This will make the auxiliary
heat your only source of heat. Be sure to restore it
to PUMP when the pump is again operational, as
auxiliary heat is more expensive than pump heat.
For more information, see page 3.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Providing a brighter solution.TM; Thermostat Installation Guide; Using the SAVE ENERGY Button; Part One: Operating Guide

2 Providing a brighter solution.™ CA8900 Z-Wave ® Thermostat Installation Guide The NORMAL and SAVE ENERGY buttons allow you to quickly switch from the NORMAL programmed target temp to a pre-determined set-back temperature, called the Save Energy temp. When in HEAT mode: • Press the a. SAVE ENERGY b...

Page 3 - Low Battery Warning; BIND; Celsius/Fahrenheit Jumper; Network

3 Providing a brighter solution.™ CA8900 Z-Wave ® Thermostat Installation Guide When the batteries are low, the battery icon on the display panel will flash. The two AA batteries in the unit need to be replaced. These batteries are not for operation, but provide battery backup for your settings. The...

Page 4 - Part Two: Installing Guide; Replacement installations; – Location of Thermostat; Tools Needed; Read instructions carefully before remov-; Do not turn electricity back on until work is completed.; WARNING–Risk of Fire or Electric Shock; Do not short (jumper) across electric terminals at control on

4 Providing a brighter solution.™ CA8900 Z-Wave ® Thermostat Installation Guide Part Two: Installing Guide Replacement installations —mount the new thermostat in place of the old one. New installations —follow the guidelines listed below. Locate the thermostat on an inside wall, about 5 ft. • (1.5m)...

Other Trane Models