Toro 830S - Manual
Toro 830S – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Nozzle Color Code; Sprinkler Application Data; Precipitation Rate Formulas
- Page 3 – Installation Procedure; Constructing Swing Joints; deterioration of sprinkler body threads.; Connecting Control Wires; CAUTION: All wire splices and field; Connecting Hydraulic Control Tubing; Table 2: Hydraulic Control Systems; Table 1: Wire Sizing Chart; Figure 1
- Page 4 – Pilot Valve; PROBLEM
- Page 5 – Sprinkler Assembly; SPRINKLER WON'T ROTATE; Main Valve
- Page 6 – Servicing Procedures; Servicing Sprinkler Mechanism
- Page 7 – Servicing Main Valve; Reinstall valve assembly using valve insertion tool P/N 995-76; • Load snap ring on insertion tool carrier with stepped side; • Load valve assembly on carrier as shown.; Figure 6
- Page 8 – Servicing Pilot Valve; Note: Refer to Figure 7 for the following procedure.; Flushing Sprinkler; Figure 7; WARNING
Introduction ______________________________________________________________________
The 830S and 850S series full-circle rotary sprinklers are designed
specifically for golf course applications.
Manufactured from durable, high-strength engineering plastic and
stainless-steel components, these sprinklers incorporate many innovative
and time-proven features for lasting, maintenance-free operation.
Prior to installing the sprinkler, read through the recommended installation
and start-up procedures. Please observe all WARNINGS and CAUTIONS
when installing and operating this equipment.
Features
_______________________________________________________________________________
Specifications and Performance/Application Data _______________________________________
830S Series
■
Radius: 55 – 89' (16.8 – 27.1 m)
■
Flow Rate: 13.6 – 45.3 GPM (51.4 – 171.5 l/mn)
■
Trajectory: 25°
■
Arc: Full Circle
■
Recommended Operating Pressure: 50 –100 PSI
(3.5 – 6.9 Bar)
■
Minimum Pressure: 40 PSI (2.8 Bar)
■
Maximum Pressure: 150 PSI (10.3 Bar)
■
Precipitation Rate:
■
Minimum: 0.46"/hr (11.7 mm/hr)
■
Maximum: 0.63"/hr (16 mm/hr)
■
Body Height: 10" (25.4 cm)
■
Pop-Up Height: 3" (7.6 cm)
■
1" NPT, BSP or ACME Female Thread Inlet
■
Spike Guard
TM
Solenoid:
■
24 V a.c., 50/60 Hz
■
Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)
60 Hz, 0.12 Amps (2.9 VA)
■
Holding Current: 50 Hz, 0.15 Amps (3.6 VA)
60 Hz, 0.10 Amps (2.4 VA)
■
Manual Control (Electric VIH only) : On-Off-Auto
■
Check-O-Matic model checks up to 37' (11.3 m) of elevation.
■
Nozzle Variations: See chart on page 2.
850S Series
■
Radius: 55'–100' (16.7 m – 30.4 m)
■
Flow Rate: 13.9 – 61.7 GPM (52.6 – 233.5 l/mn)
■
Trajectory: 25°
■
Arc: Full Circle
■
Recommended Operating Pressure: 50–100 PSI (3.5–6.9 Bar)
■
Minimum Pressure: 40 PSI (2.8 Bar)
■
Maximum Pressure: 150 PSI (10.3 Bar)
■
Precipitation Rate:
■
Minimum: 0.50"/hr (12.7 mm/hr)
■
Maximum: 0.72"/hr (18.3 mm/hr)
■
Body Height: 11" (27.9 cm)
■
Pop-Up Height: 3" (7.6 cm)
■
1.5" NPT, BSP or ACME Female Thread Inlet
■
Spike Guard
TM
Solenoid:
■
24 V a.c., 50/60 Hz
■
Inrush Current: 50 Hz, 0.17 Amps (4.1 VA)
60 Hz, 0.12 Amps (2.9 VA)
■
Holding Current: 50 Hz, 0.15 Amps (3.6 VA)
60 Hz, 0.10 Amps (2.4 VA)
■
Manual Control (Electric VIH only): On-Off-Auto
■
Check-O-Matic model checks up to 37' (11.3 m) of elevation.
■
Nozzle Variations: See chart on page 2.
830S Electric Valve-In-Head
850S Electric Valve-In-Head
■
Full 3" (7.6 cm) pop-up clears tall grasses
■
Nozzles color-coded by radius and gallonage
■
Cap serves as an effluent water indicator
■
Variable stator
■
Standard pressure regulation settings of 50 psi (3.4 bar),
65 psi (4.5 bar), 80 psi (5.5 bar) or 100 PSI (6.9 bar) to
ensure consistently accurate nozzle performance
regardless of elevation
■
Three body activation types available: Electric VIH,
Normally Open Hydraulic VIH, and Check-O-Matic
■
Three body thread types available: NPT, BSP and ACME
■
Manual control at the sprinkler, On-Off-Auto (Electric VIH only)
■
Bowl-vented discharge (atmospheric) minimizes the
differential pressure required for regulation and ensures
positive valve closure (Electric VIH only)
■
All internal components serviceable from the top of the
sprinkler
■
Large selection of color-coded nozzles available
■
Durable plastic and stainless-steel construction
■
Spike-Guard
TM
solenoid for superior surge protection
1
A U
T O
O N
830S and 850S Series Rotary Sprinklers
Installation & Service Instructions
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
2 66 26.2 31.5 34.136.5 74 8083 31.8 73 32.7 75 36.139.5 7983 41.6 44.2 8387 48.151.6 8589 850S Series Sprinkler Performance Data 830S Series Sprinkler Performance Data Nozzle Color Code Nozzle Main Inner Intermediate 1 Yellow Yellow Blue 2 Blue Yellow Blue 3 Brown Yellow Orange 4 Orange Yellow Oran...
Installation Procedure ___________________________________________________ To assure maximum performance from your 800S series sprinklers, read these instructionscompletely prior to installation or service. Constructing Swing Joints 1. Construct or provide triple swing joints for each sprinkler as s...
System Start Up _________________________________________________________ The following is a recommended procedure that will protect system components during system start-up. The procedure is based on avelocity fill rate of less than 2' (.61 m) per second. See Table 3 below. Table 3: Recommended Sys...