  • Page 2 – Installation Procedure; Figure 2; Figure 3
  • Page 3 – Select the Installation Site:; – Locate the RainSensor + Freeze model in the coolest por-; Install the RainSensor; the housing vertically.; Figure 4; Thumbscrew; Figure 5; Stainless Steel
  • Page 4 – Connect RainSensor Wiring:; wire through structure walls.; Caution: To prevent severe equipment damage, never connect the
  • Page 5 – • Remove all common wires from the common terminal(s) and join to one; Testing the RainSensor Installation; The installation and operation of a freeze sensor should be used; Caution: Visual checks and prudent manual watering suspension; Common Wire From Valves
  • Page 6 – RainSensor Operation; humidity and wind— the same conditions exposed to your landscape.; Specifications; rain gutter bracket or screws (2 provided); The Toro Promise — Limited One-Year Warranty
  • Page 7 – RainSensor; Guía de instalación; Figura 1
  • Page 8 – Procedimiento de instalación; Al realizar el ajuste, compruebe que la ranura quede; Figura 2; Figura 3
  • Page 9 – Seleccione el lugar de instalación:; Ubique el modelo de sensor de lluvia y helada en el sitio más; Instale el sensor de lluvia; Ver la; figura 4; inoxidable provistos. Ver la; figura 5; alojamiento verticalmente.; Figura 4; Tornillo de mariposa; Figura 5; Tornillos de
  • Page 11 – Conecte el conductor restante al terminal común de la válvula.; Prueba de la instalación del sensor de lluvia; Cable común de las válvulas
Loading the manual

Introduction

Adding a RainSensor or RainSensor + Freeze

to your automatic sprinkler system is an

effective means of conserving water and

lowering your monthly water bill, while

promoting a healthier lawn and garden.

Designed for ease of installation, your sensor-

controlled irrigation system will be up and

running in minutes.
Prior to installing the RainSensor, take a few

moments to read through the instructions in

their entirety. Since the RainSensor is designed

to work with most makes and models of

automatic sprinkler timers, you should also refer

to the instructions provided with your timer for

specific information regarding the connection

and use of a rain sensor or rain switch.

Important:

The RainSensor is rated for 24 VAC power only. Connecting to a higher

voltage may result in severe equipment damage.
Installation methods must comply with all applicable national and local

electrical codes. If you are unsure about proper wiring practices, have a

qualified contractor perform the installation for you.
The RainSensor must not be submerged. Do not install the sensor inside a

rain gutter or any location where water can accumulate.

RainSensor Components

1 -

Test Spindle

- Pressed to manually test

RainSensor operation.

2 - Rainfall Adjustment Cap

- Adjusts

RainSensor sensitivity from 3mm to 25mm

of detected rainfall.

3 - Quick-Clip

TM

- Universal mounting bracket

for easy installation.

4 - Connection Cable -

25ft (7.6m) of connec-

tion cable included.

5 - Access Cover -

Easily

removed for access

to internal components.

Wired RainSensor

TM

- Model 53769

RainSensor

TM

+ Freeze - Model 53853

Installation Guide

1

2

3

4

Figure 1

5

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installation Procedure; Figure 2; Figure 3

Installation Procedure v Adjust Rain Sensitivity: The sensitivity setting determines the amount of rainfall required to trigger the RainSensor and suspend automatic watering. The RainSensor is factory-set at 6mm. Prior to installing the RainSensor, adjust the rainfall sensitivity as preferred to one...

Page 3 - Select the Installation Site:; – Locate the RainSensor + Freeze model in the coolest por-; Install the RainSensor; the housing vertically.; Figure 4; Thumbscrew; Figure 5; Stainless Steel

v Select the Installation Site: To operate properly, the RainSensor must be installed in an outdoor location that provides the following conditions:• As close to the timer as possible. If the connection wire will not reach the timer, it can be extended to 100ft (30m) using 18 AWG (1.0mm 2 ) insulate...

Page 4 - Connect RainSensor Wiring:; wire through structure walls.; Caution: To prevent severe equipment damage, never connect the

v Connect RainSensor Wiring: Route the RainSensor connection wire into the timer through the access hole in the base of the timer cabinet. Note: Avoid routing the wire over any sharp edges where damage to the wire insulation may occur. For best results, hide the wire as much as possible by tucking i...

Other Toro Models

All Toro Other