A dryer duct booster fan system, such as the LB2 model, is designed to enhance airflow in residential laundry appliances by integrating a secondary lint trap (e.g., LT4) into the ventilation setup. This setup addresses critical operational topics like installation requirements–including proper placement relative to dryer and vent lengths–and ensures optimal performance through coordinated sizing and positioning of components. The manual also covers essential functional areas such as ductwork compatibility, airflow dynamics, and safety considerations for effective lint removal and ventilation efficiency.
T J E R N L U N D P R O D U C T S , I N C .
1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • w w w . t j e r n l u n d . c o m
The LT4 is a Secondary Dryer Lint Trap for use when a
Dryer Duct Booster Fan is installed less than the recom-
mended 15 equivalent feet from the dryer exhaust connec-
tion.
The Lint Trap must be installed in an accessible location for
the dryer user.
It is recommended the LT4 is inspected and accumulated
lint is removed prior to each dryer operation.
Typically the LT4 is installed in the dryer duct just above the
dryer.
INSTALLATION WITH TJERNLUND MODEL LB2 DRYER DUCT BOOSTER FAN
The LB2 is intended for use in 4” diameter dryer exhaust ducts from 30 to 150 equivalent feet* in length.
*Equivalent feet equals linear feet plus 5 additional feet for each 90° elbow and 2.5 feet for each 45° elbow
(assumes 4” diameter rigid metal duct).
Dryer Booster Fan Distance from Dryer and Termination Hood
The LB2 Dryer Booster fan positioning is based on the total Duct Length Equivalent Feet*. The Dryer Booster
should not
be
installed closer to the Dryer than what is indicated in the chart. The LT4 Secondary Lint Trap must be installed about 4 linear
feet from the Dryer and the Booster must be installed after LT4 (between the LT4 and outdoor termination hood).
For best performance install Dryer Booster no closer than 2 feet from the termination to the outdoors and avoid installing elbows
within 2 feet of the Dryer Booster.
Lint Trap 4 Feet
With a Secondary
from the Dryer (Y)
30
40
50
60
70
80
90
100
110
120
130
140
150
25
20
20
8
10
10
15
15
20
20
8
8
8
Total Duct Length
In Equivalent Feet*
(A)
from the Dryer
In Equivalent Feet*
Minimum Distance
LB2
FIGURE 8052085 11-2-15
DRYER
RESIDENTIAL
LINT TRAP
SECONDARY
DRYER
VENT WITH
DAMPER
DRYER ROOF VENT
WITH DAMPER
LB2
LB2
4 FT.
OR
2 FT. MINIMUM
A = DRYER VENT DUCT TOTAL EQUIVALENT LENGTH.
Y = SHORTEST DISTANCE LB2 CAN BE TO DRYER WITH
Y
A
SECONDARY LINT TRAP. SEE TABLE.
LT4 4” Secondary Dryer Lint Trap
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Was this manual helpful?
About this manual
- Brand
- Tjernlund
- Model
- LT4
- Document type
- User Manual
- Category
- Air Conditioner
- Language(s)
- English
- Pages
- 2
- File size
- 137.7 KB
- Format