Tjernlund LT4 - User Manual

Tjernlund LT4

Tjernlund LT4 Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
Page: / 2
Loading the manual

T J E R N L U N D P R O D U C T S , I N C .

1601 Ninth Street • White Bear Lake, MN 55110-6794
PHONE (800) 255-4208 • (651) 426-2993 • FAX (651) 426-9547
Visit our web site • w w w . t j e r n l u n d . c o m

The LT4 is a Secondary Dryer Lint Trap for use when a
Dryer Duct Booster Fan is installed less than the recom-
mended 15 equivalent feet from the dryer exhaust connec-
tion.

The Lint Trap must be installed in an accessible location for
the dryer user.

It is recommended the LT4 is inspected and accumulated
lint is removed prior to each dryer operation.

Typically the LT4 is installed in the dryer duct just above the
dryer.

INSTALLATION WITH TJERNLUND MODEL LB2 DRYER DUCT BOOSTER FAN

The LB2 is intended for use in 4” diameter dryer exhaust ducts from 30 to 150 equivalent feet* in length.

*Equivalent feet equals linear feet plus 5 additional feet for each 90° elbow and 2.5 feet for each 45° elbow

(assumes 4” diameter rigid metal duct).

Dryer Booster Fan Distance from Dryer and Termination Hood

The LB2 Dryer Booster fan positioning is based on the total Duct Length Equivalent Feet*. The Dryer Booster

should not

be

installed closer to the Dryer than what is indicated in the chart. The LT4 Secondary Lint Trap must be installed about 4 linear
feet from the Dryer and the Booster must be installed after LT4 (between the LT4 and outdoor termination hood).

For best performance install Dryer Booster no closer than 2 feet from the termination to the outdoors and avoid installing elbows
within 2 feet of the Dryer Booster.

Lint Trap 4 Feet

With a Secondary

from the Dryer (Y)

30

40

50

60

70

80

90

100

110

120

130

140

150

25

20

20

8

10

10

15

15

20

20

8

8

8

Total Duct Length

In Equivalent Feet*

(A)

from the Dryer

In Equivalent Feet*

Minimum Distance

LB2

FIGURE 8052085 11-2-15

DRYER

RESIDENTIAL

LINT TRAP

SECONDARY

DRYER

VENT WITH

DAMPER

DRYER ROOF VENT

WITH DAMPER

LB2

LB2

4 FT.

OR

2 FT. MINIMUM

A = DRYER VENT DUCT TOTAL EQUIVALENT LENGTH.

Y = SHORTEST DISTANCE LB2 CAN BE TO DRYER WITH

Y

A

SECONDARY LINT TRAP. SEE TABLE.

LT4 4” Secondary Dryer Lint Trap

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.