Thermo Pride OH8FA119D60B - Manual

Thermo Pride OH8FA119D60B

Thermo Pride OH8FA119D60B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
77 Page 77
78 Page 78
Page: / 78

Table of Contents:

  • Page 2 – CONTENTS
  • Page 3 – ii
  • Page 4 – This furnace is not to be used as a construction heater.; WARNING: DO NOT START BURNER UNLESS BLOWER DOOR IS SECURED IN
  • Page 6 – explained in the; Homeowner/User Information and Routine Maintenance; section of this manual.; Combustible material:
  • Page 7 – Airflow Requirements and Sizing of; Airflow Requirements and Sizing of Ductwork; THESE OPENINGS MUST BE FREE AND UNOBSTRUCTED.
  • Page 8 – Combustible Material:; FRONT; Note
  • Page 9 – Stack gas may do one of two things as it escapes up the chimney:
  • Page 12 – REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION:; A. Equal the required clearance with no protection.
  • Page 13 – Notice; : Blocked Vent Switch Installation; CAUTION MUST BE TAKEN NOT TO EXCEED 90°; Beckett AFG
  • Page 14 – Note: Do not use with Direct Vent application.; unless specified otherwise by the individual coil manufacturer.; Airflow Requirements and Sizing of Duct Work:; This furnace has been designed to
  • Page 16 – this method for sizing the supply side ductwork for a
  • Page 17 – The; RETURN AIR DUCT SYSTEM; should equal the warm air duct system in airflow capabilities.
  • Page 18 – E. Air Filter Mounted External to Furnace:; On; highboy
  • Page 19 – performance and/or void the warranty on this unit.
  • Page 20 – Model Number; Disposable
  • Page 22 – DO NOT CHANGE POSITION OF THE CHAMBER!; H. BURNER SPECIFICATIONS AND APPLICATIONS:; For more specific burner information, contact:
  • Page 23 – BURNER; OIL NOZZLE CAPACITY CHART
  • Page 25 – Where practical, provide rigid supports for the piping.; Avoid running tubing against any type of heating unit and across; If possible, install the tubing under the floor.; Do; Avoid the use of tube fittings in inaccessible locations.
  • Page 26 – C temperature rise. Depending upon
  • Page 27 – Please be certain that all; The rating
  • Page 28 – Thermostat Anticipator Setting:
  • Page 29 – Preferred method of adjustment:
  • Page 30 – If a slightly
  • Page 31 – Heating Speed Set-ups; Furnace Motor Current
  • Page 38 – M. BLOWER CONTROLLER INFORMATION FOR PSC MOTOR
  • Page 41 – Heat Mode; Motor Blower Speed
  • Page 42 – DIAGNOSTIC FEATURES; The red Board Status LED has two functions:
  • Page 43 – Operating Instructions:; For Your Safety Read Before Operating:; : If you do not follow these instructions exactly, a fire or
  • Page 45 – Replace the inspection cover above the burner.; COMBUSTION HEAD SETTING FOR 2-STAGE RIELLO BURNER:
  • Page 46 – AIR DAMPER ADJUSTMENT:; mount the cover, simply by means of the upper screw
  • Page 47 – In this way the burner will remain permanently in the 1; In this way the burner remains permanently in the 2
  • Page 49 – Initial Burner Adjustment; Setting Supply Air Temperature Rise:; Temperature rise = supply air temperature - return air temperature.
  • Page 50 – Heating System Initial Startup
  • Page 51 – III. USERS INFORMATION SECTION; The burner requires a generous amount of clean combustion air; EXTERIOR OF FURNACE:; The furnace vent pipe should be inspected for signs of rust,; CAUTION: DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF!
  • Page 52 – Set thermostat substantially above room temperature.; To avoid injury from moving parts, hot surfaces, or electrical
  • Page 53 – Information and Routine Maintenance; Dealer
  • Page 55 – A one inch (outside diameter) vacuum cleaner hose will fit into the
  • Page 56 – Vacuum Hose Length
  • Page 57 – check out procedures; Filter maintenance procedure:
  • Page 58 – Air Filters; Disconnect all electrical power to the unit.; Primary reset has been engaged more than two times.
  • Page 59 – Follow the previous; Initial Burner Operation
  • Page 60 – If the unit will not operate in the heating mode,; it may be possible to reactivate the unit by resetting; Beckett Burner
  • Page 61 – Contact a qualified heating; THIS SECTION IS ONLY TO BE PERFORMED BY TRAINED, QUALIFIED SERVICE
  • Page 62 – Diagnostic Features:; In event this control malfunctions, the entire control
  • Page 64 – VIII. Sequence of Operations Flow Chart:
  • Page 72 – Appendix – A
Loading the manual


MO-437
ECN 5338-MA 140301

Made IN USA

OIL FIRED FURNACE

INSTALLATION AND OPERATION MANUAL

WITH USERS INFORMATION SECTION

MODEL:

OH6FA072D48B

OH6FA072DV4B

OH8FA119D60B

OH8FA119DV5B

OH6FA072D48R

OH6FA072DV4R

OH8FA119D60R

OH8FA119DV5R

OH6FA072D48N

OH6FA072DV4N

OH6FX072DV4R

WARNING:

IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A

FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR
LOSS OF LIFE.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR

MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, OR SERVICE
AGENCY.


PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE
PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH
THE USER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE
PERSONNEL.

THERMO PRODUCTS, LLC.

PO BOX 217

NORTH JUDSON, IN 46366

PHONE: (574) 896-2133

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS

i CONTENTS SECTION PAGE I. SAFETY SECTION 1 A. CODES AND CLEARANCES 3 B. MAKE-UP AIR 4 II. GENERAL INSTRUCTIONS 5 A. CHIMNEY 6 B. VENTING 10 C. DRAFT REGULATORS 11 D. DUCT WORK/AIR CONDITIONING 11 E. AIR FILTER(S) 15 F. LIMIT POSITION AND LOCATION 17 G. BURNER INSTALLATION 18 H. BURNER SPECIFICATION...

Page 3 - ii

ii Model Number Digit 1 2 3 4 5 6 7 8 9 10 11 12 F u e l C o n fi g u ra ti o n H eat E xch an g e r Id e n ti fi e r F lu e F e a tu re C ap aci ty C ap aci ty C ap aci ty B lo w er T yp e C lg A ir fl o w C a p . C lg A ir fl o w C a p . B u rn e r Oil Furnace Model Nomenclature Example Model Numb...

Page 4 - This furnace is not to be used as a construction heater.; WARNING: DO NOT START BURNER UNLESS BLOWER DOOR IS SECURED IN

1 I. SAFETY SECTION This page and the following contains various warnings and cautions found throughout the Oil Furnace Manual. Please read and comply with the statements below.  WARNING AND CAUTIONS:  WARNING: This furnace is not to be used as a construction heater. See Page 3  WARNING: The pred...

Other Thermo Pride Models