Thermo Pride OD6FA072D48R - Manual

Thermo Pride OD6FA072D48R

Thermo Pride OD6FA072D48R – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
76 Page 76
Page: / 76

Table of Contents:

  • Page 2 – CONTENTS
  • Page 3 – ii
  • Page 4 – This furnace is not to be used as a construction heater.
  • Page 6 – explained in the; Homeowner/User Information and Routine Maintenance; section of this manual.; Combustible material:
  • Page 7 – Airflow Requirements and Sizing of; Airflow Requirements and Sizing of Ductwork; THESE OPENINGS MUST BE FREE AND UNOBSTRUCTED.
  • Page 8 – II. GENERAL INSTRUCTIONS - READ BEFORE START OF INSTALLATION; Combustible Material:; FRONT; Note
  • Page 9 – The; inside area of the chimney liner; should equal, at minimum, the area of the vent pipe exiting the; minimum; inside area of the chimney. If more than one appliance vent
  • Page 12 – REDUCTION OF CLEARANCES WITH SPECIFIED FORMS OF PROTECTION:; in each direction to make C equal to A.
  • Page 13 – CAUTION MUST BE TAKEN NOT TO EXCEED 90°; Beckett AFG
  • Page 14 – unless specified otherwise by the individual coil manufacturer.; Airflow Requirements and Sizing of Duct Work:; This furnace has been designed to
  • Page 16 – this method for sizing the supply side ductwork for a
  • Page 17 – RETURN AIR DUCT SYSTEM; should equal the warm air duct system in airflow capabilities.
  • Page 18 – performance and/or void the warranty on this unit.; Disposable
  • Page 19 – DO NOT remove
  • Page 22 – DO NOT CHANGE POSITION OF THE CHAMBER!; H. BURNER SPECIFICATIONS AND APPLICATIONS:; For more specific burner information, contact:
  • Page 23 – Riello 2-stage burner specifications and applications:; BURNER G5D; Riello Corporation of America,; OIL NOZZLE CAPACITY CHART
  • Page 25 – Where practical, provide rigid supports for the piping.; Avoid running tubing against any type of heating unit and across; If possible, install the tubing under the floor.; Do; Avoid the use of tube fittings in inaccessible locations.
  • Page 26 – C temperature rise. Depending upon
  • Page 27 – Please be certain that all; The rating
  • Page 28 – Thermostat Anticipator Setting:
  • Page 29 – Preferred method of adjustment:
  • Page 30 – If a slightly
  • Page 35 – M. BLOWER CONTROLLER INFORMATION FOR PSC MOTOR
  • Page 38 – Blower On and Off Delays
  • Page 39 – PSC TROUBLE SHOOTING; DIAGNOSTIC FEATURES; The red Board Status LED has two functions:
  • Page 40 – Operating Instructions:; For Your Safety Read Before Operating:; : If you do not follow these instructions exactly, a fire or
  • Page 42 – Replace the inspection cover above the burner.; COMBUSTION HEAD SETTING FOR 2-STAGE RIELLO BURNER:
  • Page 43 – AIR DAMPER ADJUSTMENT:; mount the cover, simply by means of the upper screw
  • Page 44 – In this way the burner will remain permanently in the 1; In this way the burner remains permanently in the 2
  • Page 46 – Initial Burner Adjustment; Setting Supply Air Temperature Rise:; Temperature rise = supply air temperature - return air temperature.
  • Page 47 – Heating System Initial Startup
  • Page 48 – III. USERS INFORMATION SECTION; The burner requires a generous amount of clean combustion air; EXTERIOR OF FURNACE:; The furnace vent pipe should be inspected for signs of rust,; CAUTION: DO NOT ATTEMPT TO MAKE REPAIRS YOURSELF!
  • Page 49 – Set thermostat substantially above room temperature.; To avoid injury from moving parts, hot surfaces, or electrical
  • Page 50 – Information and Routine Maintenance; Dealer
  • Page 52 – A one inch (outside diameter) vacuum cleaner hose will fit into the
  • Page 54 – check out procedures; Filter maintenance procedure:
  • Page 55 – Air Filters; Primary reset has been engaged more than two times.
  • Page 56 – Initial Burner Operation
  • Page 57 – If the unit will not operate in the heating mode,; it may be possible to reactivate the unit by resetting
  • Page 59 – In event this control
  • Page 61 – VIII. Sequence of Operations Flow Chart:
  • Page 68 – CUSTOMER; COMBUSTION
  • Page 69 – Appendix – A
Loading the manual


MO-458
ECN 4936-MA

Made IN USA

OIL FIRED FURNACE

INSTALLATION AND OPERATION MANUAL

WITH USERS INFORMATION SECTION

MODEL: Counterflow / Horizontal

OD6FA072D48B OD6RA072D48B OD6FX072DV5R
OD6FA072DV5B OD6RA072DV5B OD6RX072DV5R
OD6FA072D48R

OD6RA072D48R

OD6FA072DV5R OD6RA075DV5R

c

WARNING:

IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY, A

FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY, OR
LOSS OF LIFE.

DO NOT STORE OR USE GASOLINE OR OTHER FLAMMABLE VAPORS AND LIQUIDS IN THE
VICINITY OF THIS OR ANY OTHER APPLIANCE.

c

WARNING:

IMPROPER INSTALLATION, ADJUSTMENT, ALTERATION, SERVICE, OR

MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL. FOR
ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIED INSTALLER, OR SERVICE
AGENCY.


PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE
PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH
THE USER AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE
PERSONNEL.

THERMO PRODUCTS, LLC.

PO BOX 217

NORTH JUDSON, IN 46366

PHONE: (574) 896-2133

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - CONTENTS

i CONTENTS SECTION PAGE I. SAFETY SECTION 1 A. CODES AND CLEARANCES 3 B. MAKE-UP AIR 4 II. GENERAL INSTRUCTIONS 5 A. CHIMNEY 6 B. VENTING 10 C. DRAFT REGULATORS 11 D. DUCT WORK/AIR CONDITIONING 11 E. AIR FILTER(S) 15 F. LIMIT POSITION AND LOCATION 16 G. BURNER INSTALLATION 16 H. BURNER SPECIFICATION...

Page 3 - ii

ii Model Number Digit 1 2 3 4 5 6 7 8 9 10 11 12 Fuel Configuration Heat Exchanger Identifier Flue Feature Capacity Capacity Capacity Blower Type Clg Airflow Cap. Clg Airflow Cap. Burner Oil Furnace Model Nomenclature Example Model Numbers O D 6 F A 0 7 2 D 4 8 B O D 6 F A 0 7 2 D V 5 R O D 6 R A 0 ...

Page 4 - This furnace is not to be used as a construction heater.

1 I. SAFETY SECTION This page and the following contains various warnings and cautions found throughout the Oil Furnace Manual. Please read and comply with the statements below. c WARNING AND CAUTIONS: c WARNING: This furnace is not to be used as a construction heater. See Page 3 c CAUTION MUST BE T...