Thermo Pride GDM1-80N - Manual
Thermo Pride GDM1-80N – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – : If the temperature rise exceeds 85°F, the heat exchanger may fail
- Page 7 – recreational vehicles.
- Page 8 – Combustible material:
- Page 9 – III. FURNACE SPECIFICATIONS; PROPANE 11
- Page 10 – BLOWER DATA
- Page 11 – connect a ducted return air system directly to
- Page 13 – Figure 2
- Page 14 – Figure 3
- Page 15 – CAUTION: A permanent opening with a minimum of 50 square inches of; must; be provided; Figure 4
- Page 16 – HAZARD OF
- Page 18 – Figure 6
- Page 23 – Seconds for one revolution; GAS PRESSURE CHART FOR ALL GMD1-60 and GMD1-80 MODEL; SUPPLY PRESSURE; TABLE 2
- Page 25 – Figure 8; F. If the outlet or supply duct
- Page 26 – N. FURNACE CHECKOUT PROCEDURE; b. Block return air opening or disconnect blower motor leads.
- Page 27 – The sequence of operation of the furnace.
- Page 28 – VI. STARTING THE UNIT
- Page 30 – VII. TROUBLESHOOTING; BEFORE TROUBLESHOOTING, FAMILIARIZE YOURSELF WITH THE
- Page 31 – : Power must be disconnected before servicing; If the
- Page 36 – VIII. DEALER MAINTENANCE; Personal injury or property damage could result from repair or; Shut off gas and disconnect power before continuing.
- Page 37 – be cleaned or
- Page 38 – be; G. HOUSE AIR BLOWER; Some motors are permanently lubricated; and should not be oiled.; Set the room thermostat above room temperature.
- Page 39 – IX. USER INFORMATION SECTION; The area around the furnace should be kept free and clear of
- Page 42 – APPENDIX A – REPLACEMENT PARTS
- Page 44 – APPENDIX B – WIRING DIAGRAM
THERMO PRODUCTS, LLC.
POST OFFICE BOX 217
NORTH JUDSON, IN 46366
PHONE: (574) 896-2133
MG-505
ECN 5320-MA 130307
MADE IN USA
GAS-FIRED FURNACE
DOWN FLOW & DIRECT VENT (SEALED COMBUSTION)
MODELS: GMD1-60N and GMD1-80N
INSTALLATION AND SERVICE MANUAL
For installation in:
1. Manufactured Homes
2. Modular Homes/Buildings
3. Site Constructed—Residential (Single Story Dwellings)
:
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this
or any other appliance.
WHAT TO DO IF YOU SMELL GAS
•
Do not try to light any appliance.
•
Do not touch any electrical switch; do not use any phone in your building.
•
Immediately call your gas supplier from a neighbor’s phone.
Follow the gas supplier’s instructions.
•
If you cannot reach your gas supplier, call the fire department.
:
If the information in these instructions is not followed exactly, a fire or explosion may
result causing property damage, personal injury, or loss of life.
: Improper installation, adjustment, alteration, service, or maintenance can cause
injury or property damage. Refer to this manual. For assistance or additional information, consult
a qualified installer, service agency, or fuel supplier.
: Do not use this appliance if any part has been underwater. Immediately call a
qualified service technician to inspect the appliance and to replace any part of the electrical or
control system that has been underwater.
PLEASE READ THESE INSTRUCTIONS PRIOR TO INSTALLATION, INITIAL FIRING, AND BEFORE
PERFORMING ANY SERVICE OR MAINTENANCE. THESE INSTRUCTIONS MUST BE LEFT WITH THE USER
AND SHOULD BE RETAINED FOR FUTURE REFERENCE BY QUALIFIED SERVICE PERSONNEL.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
All installations and services must be performed by qualified service personnel. 1 I. SAFETY SECTION This page and the following two pages contain various warnings and cautions found throughout this furnace Service and Installation Manual. Please read and comply with the statements on the cover and ...
All installations and services must be performed by qualified service personnel. 6 II. GENERAL INSTRUCTIONS AND CLEARANCES NOTE: READ THIS SECTION BEFORE STARTING INSTALLATION 1. This furnace is equipped with orifices for operation with natural gas. For conversion to propane gas, see instructions in...
All installations and services must be performed by qualified service personnel. 7 : The area around the furnace must be kept free and clear of combustible materials, especially papers and rags. : This furnace is not to be used as a construction heater. 6. Definitions of "combustible" and ...