Thermador 98 - Manual
Thermador 98 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – TABLE OF CONTENTS; WARNING
- Page 3 – Figure 1; INTRODUCTION; GENERAL DESCRIPTION
- Page 4 – PLAN THE INSTALLATION; Remote blower installation requires 5; Follow the duct installation guidelines in Table 2.; P a r t s N e e d e d f o r R e m o t e B l o w e r :
- Page 5 – Figure 2; Be certain to avoid interference; INTEGRAL
- Page 6 – FIGURES 3 THROUGH 6 ARE EXAMPLES OF POSSIBLE DUCTING; Figure 3; Figure 5; INTEGRAL BLOWER; Figure 6; REMOTE BLOWER; REMOTE BLOWER
- Page 9 – 0” Cooktops: Installed with UCV30; OW; INSTALLATION WITH THERMADOR COOKTOPS WHEN SPECIFIED; SB
- Page 10 – If CCW is; smaller; than the UCV cutout width; I n s t a l l a t i o n; If CCW is larger than the UCV cutout width then:; Cut countertop using dims:; * Refer to Table 3 Notes on previous page.
- Page 11 – PREPARE DUCT CUTOUTS IN CABINET; TABLE 4; INTEGRAL BLOWER VTN600CVA; B . Use Table 4 to layout the necessary cabinet; Figure 9; Plumb line to
- Page 12 – Follow the; INSTALL ELECTRICAL SERVICE
- Page 13 – Wire to remote blower; Use spring type wire nuts supplied to con-; UCV WIRING DIAGRAM; R e d
- Page 14 – NOTE: To prevent damage to any internal; Down button
- Page 15 – NOTES
For Integral Blower Installations:
• Requires Integral Blower: Model # VTN600CVA
• Requires Round Duct Size (6" Diam.)
• Requires Dedicated Branch Circuit Power Supply • 120 Volt AC•
min. 15 Amps., 3 prong receptacle • 60 Hz.
• See Steps 3 and 5 for electrical receptacle and duct outlet location
For Remote Blower Installations:
• Requires Remote Blower: Model # VTR1000Q or VTR600R
• Requires Duct Transition: Model # CVT314 (for 3
-1
/
4
" x 14" duct) or
Model # CVT7 (for 7" Diam. Round)
• Requires 4 wires and 1 ground wire connecting blower and vent
• Requires Dedicated Branch Circuit Power Supply • 120 Volt • 15 Amps.,
3 prong receptacle • 60 Hz., AC.
For CVT314:
• Recommend 3
-1
/
4
" x 14" to 10" diam. transition for VTR1000Q Remote Blower
• Recommend 3
-1
/
4
" x 14" to 8" diam. transition for VTR600R Remote Blower
For CVT7:
• Recommend 7" diam. to 10" diam. transition for VTR1000Q Remote Blower
• Recommend 7" diam. to 8" diam. transition for VTR600R Remote Blower
• See Steps 3 and 5 for electrical receptacle and duct outlet location
UNIVERSAL COOK’N’VENT
®
INSTALLATION INSTRUCTIONS
MODELS: UCV30 • UCV36 • UCV45
Rating: 120 Volt, 60 Hz., 10.0 Amps.
INSTALLATION MUST COMPLY WITH ALL APPLICABLE CODES.
PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING.
I
MPORTANT:
Save these instructions for the local electrical inspector's use.
INSTALLER:
Please leave these Installation Instructions with this unit for the owner.
OWNER:
Please retain these instructions for future reference.
SAFETY WARNING:
Disconnect power by removing plug from receptacle before installing
or servicing this unit.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
SAFETY INSTRUCTIONS READ AND SAVE THESE INSTRUCTIONS A . Installation work and electrical wiring must bedone by qualified person(s) in accordance withall applicable codes and standards, includingfire-related construction. B . Sufficient air is needed for proper combustiona n d e x h a u s t i n g o ...
Figure 1 Snorkel Filters Support Leg J-Box Top Cap Blower Assembly Wing Nuts INTRODUCTION GENERAL DESCRIPTION The complete Universal Cook‘n‘Vent ® System consists of the ventilator intake and a blower . See Fig. 1. The blower is either an integral (mounted on the vent intake in the cabinet under the...
STEP 1 PLAN THE INSTALLATION Carefully follow the planning procedures listed below.See Figure 2. A . Determine whether a remote or integral blower willbe used. Remote blower installation requires 5 wires plus a ground wire to run from theCook‘n’Vent ® to the blower. B. Make sure adequate cabinet and...