Tektronix 070-9793-02 - Manual

Tektronix 070-9793-02

Tektronix 070-9793-02 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
Page: / 48

Table of Contents:

  • Page 3 – WARRANTY
  • Page 5 – Table of Contents; General Safety Summary; Operating Basics
  • Page 6 – ii; List of Figures
  • Page 7 – Only qualified personnel should perform service procedures.; To Avoid Fire or
  • Page 8 – iv; These terms may appear in this manual:; Terms on the Product.; These terms may appear on the product:; Symbols on the Product.; The following symbols may appear on the product:; Symbols and Terms
  • Page 9 – Preface; These instructions cover the following topics:; Contacting Tektronix; To write us
  • Page 11 – Product description; Product Description; Figure 1: P6434 Mass Termination Probe
  • Page 12 – Labels; Table 1: Standard P6434 probe section and label combinations; Probe; To apply labels to the probe, follow these steps:; Standard Method
  • Page 13 – Figure 2: Applying labels; Connecting the P6434 Probe to the SUT; To avoid damaging the probe and SUT, always position the probe; Direct Connection
  • Page 14 – Figure 3: Connecting to a surface- or straddle-mounted connector; on the logic analyzer module. The module end is keyed.
  • Page 15 – Figure 4: Connecting the Low-Profile Extender; Connection
  • Page 16 – Disconnecting the P6434 Probe from the SUT; To disconnect the P6434 probe, follow these steps:; Figure 5: Releasing the probe tip from the latch housing; To avoid damage to the probe and mating connector, hold on to the
  • Page 17 – Designing an Interface Between a P6434 Probe and a SUT; Mictor connectors; Mictor Connectors and Latch Housings; Table 2: Compatible Mictor connectors; Description; Recommended
  • Page 18 – Straddle mount; Figure 6: Latch housing dimensions; NOTE
  • Page 19 – Dimensions and Placement of Compatible Mictor Connectors
  • Page 20 – Figure 8: Side view and dimensions of the Low-Profile Extender
  • Page 24 – Probe Channel Assignments; Table 3: Pin 1 side probe channel assignments
  • Page 25 – Table 4: Pin 38 side probe channel assignments
  • Page 26 – Pin 1 Indicator; resistance returned to a 2.2 V supply. The; Table 5: Lossy delay line values; Characteristic; Figure 12: Equivalent circuit for the P6434 probe
  • Page 29 – Service Information; Probe maintenance; Maintenance
  • Page 30 – Circuit Description; Table 6: Electrical specifications; Characteristics; Table 7 shows the environmental specifications.
  • Page 31 – Table 8: Certifications and compliances
  • Page 32 – Disassembling the Probe; Figure 15: Disassembling the P6434 probe tip; hexagonal screwdriver, and open the case halves.; Probe Tip
  • Page 33 – Figure 16: Disassembling the latch release grip; Latch Release Grip
  • Page 34 – Remove the pin 1 and pin 38 cables with connectors attached.; Figure 17: Disassembling the module end; Module End
  • Page 35 – Reassembling the Probe; Use the following procedures to resassemble the P6434 probe.; Remove; Figure 18: Mictor connector circuit board and board holder; connector facing up. See Figure 20 for the correct orientation.
  • Page 36 – Figure 19: Positioning the elastomer connector; of the board holder as shown in Figure 20.; Figure 20: Positioning the circuit board in the probe
  • Page 37 – Figure 21: Reattaching the latch releases and case halves; halves, and reconnect the screws as shown in Figure 21.
  • Page 39 – Figure 24: Reassembling the module end; position the connector in the case halves.
  • Page 40 – Functional Verification; Adjustment and verification test fixture, part number 671-3599-00; Figure 25: Jumper and connector locations on the test fixture
  • Page 41 – Figure 26: Example of the Activity Indicator dialog box; This completes the functional verification.
  • Page 43 – Replaceable Parts; Parts Ordering Information; Part number; Using the Replaceable Parts List
  • Page 44 – Parts list column descriptions; Column; Abbreviations
  • Page 45 – Manufacturers cross index; Manufacturer; Replaceable parts list
Loading the manual

Instructions

P6434
Mass Termination Probe

070-9793-02

There are no current European directives that
apply to this product. This product provides
cable and test lead connections to a test object of
electronic measuring and test equipment.

Warning
The servicing instructions are for use by
qualified personnel only. To avoid personal
injury, do not perform any servicing unless you
are qualified to do so. Refer to all safety
summaries prior to performing service.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 3 - WARRANTY

WARRANTY Tektronix warrants that the products that it manufactures and sells will be free from defects in materials andworkmanship for a period of one (1) year from the date of shipment. If a product proves defective during thiswarranty period, Tektronix, at its option, either will repair the defect...

Page 5 - Table of Contents; General Safety Summary; Operating Basics

P6434 Probe Instructions i Table of Contents General Safety Summary iii . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Preface v . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Contacting Tektronix v . . . . . . . . . . ....

Page 6 - ii; List of Figures

Table of Contents ii P6434 Probe Instructions List of Figures Figure 1: P6434 Mass Termination Probe 1 . . . . . . . . . . . . . . . . . . . . . . . Figure 2: Applying labels 3 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Figure 3: Connecting to a surface- or straddle-moun...

Other Tektronix Models

All Tektronix Other