TDK iQP48070A033V - Manual
TDK iQP48070A033V – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
©2001 Innoveta
TM
Technologies, Inc.
1/2
10/19/2001
Revision 2
Product Brief: Powereta™ – Single Output High Current Double-P Quarter Brick
©2006 TDK Innoveta Inc.
iQP 2.5V to 3.3V Product Brief 4/20/2006
℡
(877) 498-0099
1/2
TDK Innoveta Base
Product Code
Input
Voltage
Output
Voltage
Output
Current
Efficiency
70%Load
Efficiency
100%Load
iQP48070A033V
36-75V
3.3V
70A
92.5%
91.5%
iQP48080A025V
36-75V
2.5V
80A
90.5%
89%
Input Characteristics
Operating input range
36-75V
Transient input voltage
100V
100mS max
Turn-on voltage
34.4V
Turn-off voltage
32.3V
Maximum input current
8 A
Input 0-75V, Io,max
Output Characteristics
Output voltage tolerance
+/- 3.3% max
Over line, load, and
temp to end of life
Efficiency
89% to 91.5%
Io,max
Line regulation
1 mV
Over rated input
Load regulation
1 mV
Over rated load
Start-up time
25 ms
On/Off to 90% Vo
Output voltage adjustment
80%-110%
%Vo,nom
Output ripple
25 - 40 mVp-p
20MHz bandwidth
Dynamic response
Transient voltage
Recovery time
150 – 200 mV
500 - 650
µ
S
Load step 25% of
Io,max
slew rate =0.1A/us
Ripple frequency
270 kHz
Fixed
Protection
Output over-current
110% of Io,rated
Auto-recovery hiccup
Short circuit
Continuous
protection
Auto-recovery hiccup
Output over-voltage
121% of Vout,nom
Latching
Thermal shutdown
126C
Auto recovery with
hysteresis
Environmental
Operating temperature, Tc
-40C to 119C
See full datasheet
The Powereta™ iQP Series offers an industry standard extra
output pins (Double-P) quarter brick high current power module
with true useable output power.
Its 89% to 91.5% full load
efficiency and superior thermal performance make the Powereta™
Series of power modules ideally suited for tight space and power-
hungry applications in demanding thermal environments. This
rugged building block is designed to serve as the core of your high
reliability system. A wide output voltage trim range, -20 to +10%,
and remote sensing are standard features enhancing versatility.
Features
•
RoHS Compliant
•
Standard Double-P Quarter Brick Pinout
•
Size: 2.28”
×
1.45”
×
0.5”
•
Up to 80A of output current
•
Power density: up to 140W / in
3
•
Maximum efficiency – up to 93.5%
•
Full load efficiency: 89% to 91.5%
•
Output power – up to 231W in high
ambient temperature, low airflow
environments with minimal derating
•
Wide output voltage trim range
•
Industry standard output voltage trim
•
Basic insulation – 1500Vdc
•
Choice of remote on/off configuration
•
Remote sense
•
Constant switching frequency
•
Latched output over-voltage protection
•
Auto-recovery full protections:
o
Input under and over voltage
o
Output over-current
o
Output short circuit
o
Thermal limit
•
UL 60950 (US and Canada), VDE 0805,
CB scheme (IEC950) Safety markings
and CE Mark (EN60950)
•
Optional 0.110”, 0.145”, 0.180” pin length
•
Optional non-latching OVP protection
•
EMI: CISPR 22 A or B with external filter
•
Multiple patents pending
•
ISO9000 certified manufacturing facilities
Powereta™ iQP Series Double-P Quarter Bricks
48V Input, 3.3V/70A and 2.5V/80A Output
Typical Performance
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.