TDK iQP Series - Manual
TDK iQP Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
©2001 Innoveta
TM
Technologies, Inc.
1/2
10/19/2001
Revision 2
Product Brief: Powereta™ – Single Output High Current Double-P Quarter Brick
©2005 TDK Innoveta Inc.
iQP 5V Product Brief 6/6/2005
℡
(877) 498-0099
1/2
TDK Innoveta Base
Product Code
Input
Voltage
Output
Voltage
Output
Current
Efficiency
70%Load
Efficiency
100%Load
iQP48050A050V
36-75V
5V
50A
93%
92%
Input Characteristics
Operating input range
36-75V
Transient input voltage
100V
100mS max
Turn-on voltage
34.7V
Turn-off voltage
32.3V
Maximum input current
8A
Input 0-75V, Io,max
Output Characteristics
Output voltage tolerance
+/- 3.3% max
Over line, load, and
temp to end of life
Efficiency
92%
Io,max
Line regulation
3 mV
Over rated input
Load regulation
3 mV
Over rated load
Start-up time
40 ms
On/Off to 90% Vo
Output voltage adjustment
80%-110%
%Vo,nom
Output ripple
80 mVp-p
20MHz bandwidth
Dynamic response
Transient voltage
Recovery time
80 mV
200
µ
S
Load step 25% of
Io,max
slew rate =0.1A/us
Ripple frequency
250 kHz
Fixed
Protection
Output over-current
108% of Io,rated
Auto-recovery hiccup
Short circuit
Continuous
protection
Auto-recovery hiccup
Output over-voltage
121% of Vout,nom
Latching
Thermal shutdown
126C
Auto recovery with
hysteresis
Environmental
Operating temperature, Tc
-40C to 112C
See full datasheet
The Powereta™ iQP Series offers an industry standard
Double-P quarter brick high current power module with true
useable output power.
The iQP series power modules are
ideally suited for high-density distributed power architectures
where the demands of voltage and substantial load mandate
the creation of a robust local intermediate 5V
distribution bus.
Its 92% full load efficiency (93% at 70% load) and superior
thermal performance make the iQP Series of power modules
ideally suited for tight space and power-hungry applications in
demanding thermal environments. This rugged building block
is designed to serve as the core of your high reliability system.
A wide output voltage trim range, -20 to +10%, and remote
sensing are standard features enhancing versatility.
Features
•
Standard Double-P Quarter Brick Pinout
•
Size: 2.28”
×
1.45”
×
0.5”
•
Up to 50A of output current
•
Power density > 151W / in
3
•
Maximum efficiency – up to 94.5%
•
Typical full load efficiency: 92%
•
Output power – up to 250W in high
ambient temperature, low airflow
environments with minimal derating
•
Wide output voltage trim range
•
Industry standard output voltage trim
•
Basic insulation – 1500Vdc
•
Choice of remote on/off configuration
•
Remote sense
•
Constant switching frequency
•
Latched output over-voltage protection
•
Auto-recovery full protections:
o
Input under and over voltage
o
Output over-current
o
Output short circuit
o
Thermal limit
•
UL 60950 (US and Canada), VDE 0805,
CB scheme (IEC950) Safety markings
and CE Mark (EN60950)
•
Optional 0.110”, 0.145”, 0.180” pin length
•
Optional non-latching OVP protection
•
EMI: CISPR 22 A or B with external filter
•
Multiple patents pending
•
ISO9000 certified manufacturing facilities
Powereta™ iQP Series Double-P Quarter Brick
48V Input, 5V/50A/250W DC Output
Typical Performance
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.