Product Brief: Veta™ iHA Series – Half Brick

©2002 Innoveta Technologies™, Inc.
iHA48011A280V product brief 090302.doc 9/4/2002

'

(877) 498-0099

1/2













Base Product Code

Input

Voltage

Output

Voltage

Output

Current

Efficiency

iHA48011A280V

36-75V

28V

11A

91%

Input Characteristics

Operating input range

36-75V

Transient input voltage

100V

100mS max

Turn-on voltage

34V

Turn-off voltage

32V

Start-up time

80 mS

On/Off to 90% Vout

Maximum input current

10.2A

Input 0-75V, Io,max

Output Characteristics

Output voltage tolerance

+/- 3% max

Over line, load, and temp

to end of life

Efficiency

see product table

Line regulation

10 mV

Over rated input

Load regulation

25 mV

Over rated load

Output voltage adjustment

54%-110%

%Vout,nom

Output ripple

250 mVp-p

20MHz bandwidth

Dynamic response
Transient voltage
Recovery time

600 mV

350 uS

Load step 25% of Io,max

slew rate =0.1A/us

Ripple frequency

300 kHz

Fixed

Protection

Current limit inception

130% of Io,rated

Short circuit

Continuous protection

Auto-recovery (AR) hiccup

Output over voltage

120% of Vout,nom

Latch (AR-optional)

Thermal shutdown

120C

Auto recovery hiccup

Environmental

Operating temperature

-40C to 120C

Measurement point in full

datasheet

Its

91% efficiency

and superior thermal performance make the Veta™

Family of power modules ideally suited for power-hungry applications in
demanding thermal environments. This rugged building block is
designed to serve as the core of your high reliability system. A wide
output voltage

trim range, -46 to +10%,

and remote sensing are

standard features enhancing versatility. For a full-featured version of the
Veta™ Half Brick, including active current sharing, see the iHD product
brief.

Typical Performance

Features

Standard Half Brick footprint

High efficiency, typical 91%

Wide output trim voltage

True 11A product at 28V output

Industry-leading output power:
300W

Monotonic start-up

Starts with a pre-biased output

Basic insulation – 1500 Vdc

Auto-recovery protection:

o

Input under and over voltage

o

Current limit

o

Short circuit

o

Thermal limit

Latched output over voltage

Optional auto-recovery output over

voltage

High reliability open frame, surface-

mount construction

Baseplate for improved thermal

management

Constant switching frequency

Optional 0.110” pin length

Safety agency approvals pending

Multiple patents pending

Veta™ iHA Series DC/DC Power Modules

48V Input, 28V/11A Output

Half Brick