TDK iEA Series - Manual

TDK iEA Series

TDK iEA Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
Page: / 41

Table of Contents:

  • Page 2 – iEA Series –Single Output Eighth Brick; TDK Innoveta
  • Page 3 – PIN; Trim
  • Page 5 – Characteristic
  • Page 7 – Rup
  • Page 9 – Thermal measurement
  • Page 36 – Dimensions are; The thermal performance data; AIRFLOW
  • Page 37 – ) and airflow rate as shown in the; Operating Information:; The power
  • Page 38 – The output; Circuit to decrease output voltage; Rdown; Circuit to increase output voltage
  • Page 39 – The power modules feature
  • Page 40 – Safety Considerations:
Loading the manual

Data Sheet: Belleta

®

iEA Series –Single Output Eighth Brick

©2004 TDK Innoveta® Inc.
iEAFullDatasheet 032707 3/29/2007 Revision 2.0

(877) 498-0099

1/41

Belleta® iEA Series DC/DC Power Modules

48V Input, 25A Output

Eighth Brick





The Belleta Series offers an industry standard
eighth brick power module with true useable
power. Thanks to its low component count and
single-board open-frame design, it provides both
better electrical and thermal performance, and
lower cost than many other suppliers’ eighth brick
product offerings. Belleta® modules are perfect
for both next generation planning and cost
reduction design environments


Standard Features:


Size – 58.4mm x 22.9 mm x 8.8
mm (2.3 in. x 0.9 in. x 0.347 in.)

Thru-hole pins 3.68 mm (0.145”)

High efficiency – greater than 89%

1500Vdc isolation voltage

Meets basic insulation spacing
requirements

Constant switching frequency

Industry Standard Footprint

Output Voltage Adjustment

Remote on/off (positive logic)

Remote sense

Auto-recovering output over-
voltage protection

Auto-recovering output over-
current protection

Auto-recovering output short circuit
protection

Auto-recovering over-temperature
protection

UL 60950 (US and Canada), VDE
0805, CB scheme (IEC950), CE
Mark (EN60950)

ISO Certified manufacturing
facilities

Patented Design


Optional Features:

Remote on/off (negative logic)

Latching output over-voltage
protection

Short Thru-hole pins 2.79 mm
(0.110”)

Long Thru-hole pins 5.08 mm
(0.200”)








"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - iEA Series –Single Output Eighth Brick; TDK Innoveta

Data Sheet: Belleta ® iEA Series –Single Output Eighth Brick ©2004 TDK Innoveta® Inc. iEAFullDatasheet 032707 3/29/2007 Revision 2.0 ℡ (877) 498-0099 2/41 Ordering information: Product Identifier Package Size Platform Input Voltage Output Current/ Power Output Units Main Output Voltage # of Outputs ...

Page 3 - PIN; Trim

Data Sheet: Belleta ® iEA Series –Single Output Eighth Brick ©2004 TDK Innoveta® Inc. iEAFullDatasheet 032707 3/29/2007 Revision 2.0 ℡ (877) 498-0099 3/41 Mechanical Specification: Dimensions are in mm [in]. Unless otherwise specified tolerances are: x.x ± 0.5 [0.02], x.xx and x.xxx ± 0.25 [0.010]. ...

Page 5 - Characteristic

Data Sheet: Belleta ® iEA Series –Single Output Eighth Brick ©2004 TDK Innoveta® Inc. iEAFullDatasheet 032707 3/29/2007 Revision 2.0 ℡ (877) 498-0099 5/41 Electrical Data: iEA48007A120V-000 through -015: 12V, 6.5A Output Characteristic Min Typ Max Unit Notes & Conditions Output Voltage Initial S...

Other TDK Models