TDK CU Series - Manual
TDK CU Series – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
(1/1)
002-02 / 20070621 / e773_cu.fm
• All specifications are subject to change without notice.
Circulators/Isolators
For Base-station, Ferrite Substrate Type
CU Series
FEATURES
• Ferrite substrate type circulator and isolator installed on
microwave IC with the same characteristics as a connector type.
PRODUCT IDENTIFICATION
Type name
∗
a
∗
b
∗
c
-
∗
d
∗
f
∗
a
:
Direction of circulation. Fill in with a letter A or B.
A: CW (clock-wise)
B: C·CW (counter clock-wise)
∗
b
:
Bandwidth
3: Wide bandwidth
∗
c
:
Connector type
L: Strip-line type
∗
d
:
Center frequency (nominal frequency)
∗
f
:
Input and output terminal position
C: Circulator specification
S, T, U: Isolator specification (Type T: Standard type)
SHAPES/INPUT AND OUTPUT TERMINAL POSITIONS
ELECTRICAL CHARACTERISTICS
• Product identifications
∗
d
: 39 means nominal frequency (Example: 39
→
3.9GHz/150
→
15.0GHz)
Type S
Resistor
Type T
Resistor
Type U
Resistor
A
C
C
B
B
A
C
B
A
C
B
Fig.1
A
Fig.3
Fig.2
Fig.4
Part No.
Frequency
range
(GHz)
Isolation
(dB)
min.
Insertion
loss
(dB)
max.
VSWR
max.
Z
0
=50
Ω
Maximum
handling
power
(W)
Capacity of
built-in
dummy
load (W)
Dimensions
(mm)
A
×
B
×
C
Temperature
range (°C)
Weight
(g)
Fig.
Circulator
Isolator
CU965T
∗
a
3L-39C CU965T
∗
a
3L-39
∗
f
3.7 to 4.2
18
(17)
0.6
(0.65)
1.3
(1.35)
4
0.25
16
×
16
×
1.5
–10 to +50
(–30 to +70)
6
1
CU965T
3L-43C
CU965T
3L-43
4.0 to 4.6
CU965T
3L-47C
CU965T
3L-47
4.4 to 5.0
CU965T
3L-55C
CU965T
3L-55
5.0 to 6.0
CU965T
3L-60C
CU965T
3L-60
5.6 to 6.5
CU965T
3L-67C
CU965T
3L-67
6.3 to 7.2
CU965T
3L-75C
CU965T
3L-75
7.1 to 7.9
CU965T
3L-81C
CU965T
3L-81
7.6 to 8.6
CU965Y
3L-39C
CU965Y
3L-39
3.7 to 4.2
18
(17)
0.6
(0.65)
1.3
(1.35)
4
0.25
16
×
16
×
1.5
–10 to +50
(–30 to +70)
6
2
CU965Y
3L-43C
CU965Y
3L-43
4.0 to 4.6
CU965Y
3L-47C
CU965Y
3L-47
4.4 to 5.0
CU965Y
3L-55C
CU965Y
3L-55
5.0 to 6.0
CU965Y
3L-60C
CU965Y
3L-60
5.6 to 6.5
CU965Y
3L-67C
CU965Y
3L-67
6.3 to 7.2
CU965Y
3L-75C
CU965Y
3L-75
7.1 to 7.9
CU965Y
3L-81C
CU965Y
3L-81
7.6 to 8.6
CU96M
3L-65T
5.8 to 7.2
20
0.4
1.2
10
2
12
×
10
×
1.8
–10 to +60
4
3
CU96M
3L-70T
6.3 to 7.6
CU96M
3L-79T
7.2 to 8.6
CU96S
3L-65T
5.8 to 7.2
20
0.4
1.2
10
10
12
×
10
×
1.8
–10 to +60
4
3
CU96S
3L-70T
6.3 to 7.6
CU96S
3L-79T
7.2 to 8.6
CU9106
3L-95T
9.0 to 10.0
18
(17)
0.6
(0.65)
1.3
(1.35)
2
0.1
10
×
10
×
1.65
–10 to +50
(–30 to +70)
4
4
CU9129
3L-131T
11.7 to 14.5
18
0.6
1.3
3
0.25
7
×
7
×
1.65
–30 to +70
3
4
CU9129
3L-150T
14.5 to 15.4
• TDK will be pleased to submit quotations on any customer’s requirements which are not included in this data.
Please contact our branch office or representative.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.