CU Series

FEATURES

• Ferrite substrate type circulator and isolator installed on

microwave IC with the same characteristics as a connector type.

PRODUCT IDENTIFICATION

Type name

a

b

c

-

d

f

a

:

Direction of circulation. Fill in with a letter A or B.
A: CW (clock-wise)
B: C·CW (counter clock-wise)

b

:

Bandwidth
3: Wide bandwidth

c

:

Connector type
L: Strip-line type

d

:

Center frequency (nominal frequency)

f

:

Input and output terminal position
C: Circulator specification
S, T, U: Isolator specification (Type T: Standard type)

SHAPES/INPUT AND OUTPUT TERMINAL POSITIONS

ELECTRICAL CHARACTERISTICS

• Product identifications

d

: 39 means nominal frequency (Example: 39

3.9GHz/150

15.0GHz)

Type S

Resistor

Type T

Resistor

Type U

Resistor

A

C

C

B

B

A

C

B

A

C

B

Fig.1

A

Fig.3

Fig.2

Fig.4

Part No.

Frequency
range
(GHz)

Isolation
(dB)
min.

Insertion
loss
(dB)
max.

VSWR
max.
Z

0

=50

Maximum
handling
power
(W)

Capacity of
built-in
dummy
load (W)

Dimensions
(mm)
A

×

B

×

C

Temperature
range (°C)

Weight
(g)

Fig.

Circulator

Isolator

CU965T

a

3L-39C CU965T

a

3L-39

f

3.7 to 4.2

18
(17)

0.6
(0.65)

1.3
(1.35)

4

0.25

16

×

16

×

1.5

–10 to +50
(–30 to +70)

6

1

CU965T

3L-43C

CU965T

3L-43

4.0 to 4.6

CU965T

3L-47C

CU965T

3L-47

4.4 to 5.0

CU965T

3L-55C

CU965T

3L-55

5.0 to 6.0

CU965T

3L-60C

CU965T

3L-60

5.6 to 6.5

CU965T

3L-67C

CU965T

3L-67

6.3 to 7.2

CU965T

3L-75C

CU965T

3L-75

7.1 to 7.9

CU965T

3L-81C

CU965T

3L-81

7.6 to 8.6

CU965Y

3L-39C

CU965Y

3L-39

3.7 to 4.2

18
(17)

0.6
(0.65)

1.3
(1.35)

4

0.25

16

×

16

×

1.5

–10 to +50
(–30 to +70)

6

2

CU965Y

3L-43C

CU965Y

3L-43

4.0 to 4.6

CU965Y

3L-47C

CU965Y

3L-47

4.4 to 5.0

CU965Y

3L-55C

CU965Y

3L-55

5.0 to 6.0

CU965Y

3L-60C

CU965Y

3L-60

5.6 to 6.5

CU965Y

3L-67C

CU965Y

3L-67

6.3 to 7.2

CU965Y

3L-75C

CU965Y

3L-75

7.1 to 7.9

CU965Y

3L-81C

CU965Y

3L-81

7.6 to 8.6

CU96M

3L-65T

5.8 to 7.2

20

0.4

1.2

10

2

12

×

10

×

1.8

–10 to +60

4

3

CU96M

3L-70T

6.3 to 7.6

CU96M

3L-79T

7.2 to 8.6

CU96S

3L-65T

5.8 to 7.2

20

0.4

1.2

10

10

12

×

10

×

1.8

–10 to +60

4

3

CU96S

3L-70T

6.3 to 7.6

CU96S

3L-79T

7.2 to 8.6

CU9106

3L-95T

9.0 to 10.0

18
(17)

0.6
(0.65)

1.3
(1.35)

2

0.1

10

×

10

×

1.65

–10 to +50
(–30 to +70)

4

4

CU9129

3L-131T

11.7 to 14.5

18

0.6

1.3

3

0.25

7

×

7

×

1.65

–30 to +70

3

4

CU9129

3L-150T

14.5 to 15.4

• TDK will be pleased to submit quotations on any customer’s requirements which are not included in this data.

Please contact our branch office or representative.