Thank  y ou  for  purchasing  a  Taylor®  infrared  thermom eter.  Please  read  this  instruction  manual  carefully  before  use. 
Keep these instructions handy for future referenc e. 

The  thermometer  is  a  non­contact  infrared  thermometer.  Simply  aim  the therm ometer  at the target  and  press the  ‘Scan 
k ey ’ to display the surface tem perature.

Temperature Reading Operation
Press the ‘Scan key’ to take a temperature
reading. The unit will display the
temperature of the target for 10 seconds
then turn off automatically.

CAUTION!

1. WHEN DEVICE IS IN USE, DO NOT

LOOK DIRECTLY INTO THE LASER
BEAM –PERMANENT EYE DAMAGE
M AY RESULT.

2. USE EXTREME CAUTION WHEN

OPERATING THE LASER.

3. NEVER POINT THE DEVICE TOWARDS

ANYONE’S EYES.

4. KEEP OUT OF REACH OF ALL CHILDREN.

Continuous Temperature Reading Operation

 

1. Press and hold down the “Scan” key. 
2. The unit will display continually updated real time tem perature readings while the “Scan” key is held down. When the 
k ey is released, the last tem perature will display for 10 seconds, and then the unit will turn off automatically.

HACCP CHECK

 

The  “HACCP  CHECK”  feature  is  inc orporated  in  our  therm ometer 
temperature to  graphically indicate critical temperature zone. The icons and 
LED  indicators  located  above  the  display  indicate  if  a  food  product  is  in  a 
s afe or unsafe HACCP “Danger Zone” temperature. The green  and red  LED 
light will always be lit before the power is turned off. 
A  Green  LED  light  with  a  ” 

”  icon  indicates  a  safe  cool  or  frozen 

c ondition  below  40 

F  (4 

C),  while  a  ” 

”  icon  indicates  a  safe  holding 

temperature above 140 

F (60 

C). 

W hen  the  temperature  is  between  40 

F  (4 

C)  and  140 

F  (60 

C),  the  red 

LED with a” 

”  icon will appear  and indicate that the temperature  is fallen within the  HACCP “Danger Zone” from  40 

to 140 

F (4~60 

C)

.

°C OR °F MODE

 

To  change  the  thermometer  from  ‘°C’ to  ‘°F’ or  from  ‘°F’ to  ‘°C’,  first  turn the  instrument  on  by  pressing  the  ‘Scan  key’, 
then press the ‘M ode key’ one time. The ‘°C’ or ‘°F’ symbol will flash. Press the ‘Scan key’ to change to scale.

EMISSIVITY RANGE

 

The  infrared  thermometer  is  supplied  with  a  default  emissivity  of  0.95.  The  emissivity  of  the  thermom eter  can  be 
changed  from  0.05  (5E)  to  1  (100E).  Changes  should  only  be  carried  out  by  experienced  personnel.  To  change  the 
emissivity,  firstly  turn  the  instrument  on  by  pressing  the  ‘Scan’  button,  then  press  the  ‘Mode’  button  two  tim es  for 
emissivity  function.  The  95E  will  flash  on  the  LCD  screen,  then  press  the  ‘M eas.’  button to  adjust  the  em issivity  value, 
press   the  ‘Mode’  button  again  to  exit  the  set  up  screen.  For  information  relating  to  the  em issivity  of  specific  materials, 
please contact  the nearest retailer. Note: non­c ontact infrared thermom eters are not recommended  for  use in m easuring 
the tem perature of s hiny or polished m etals.

BAR DISPLAY:

The fixed setting range for bar display is 68­428°F (20~220°C) and Center=248°F (120°C).

 

The bar display will be updated com ply with the measurement reading changed

.

LCD ERROR MESSAGES

 

The thermometer incorporates visual diagnostic messages as follows: 

 

‘Hi’  or  ’Lo’  is  dis played  when  the  temperature  being  measured  is   outside  of  the  range  of  the 
instrum ent, ‘Hi’ when higher than +662°F (+350°C) and ‘Lo’ when lower than ­67°F (–55°C). 

 

‘Er2’  is  displayed  when the thermometer is  exposed  to rapid  changes  in the  ambient  temperature. 
‘Er3’  is  displayed  when  the  am bient  temperature  of  the  thermometer  EXCEEDS  32°F  (0°C)  OR 
+122°F  (+50°C).  In  both  cases  you  s hould  allow  plenty  of  time  (minimum  30  minutes)  for  the 
thermometer to stabilize to the working/room temperature. 

 

For  all  other  error  messages  it  is  necessary  to  reset  the  thermometer.  To  reset  the  thermom eter, 
turn  the  instrument  off,  rem ove  the  battery  and  wait  for  a  minimum   of  one  minute,  reinsert  the 
battery  and  turn  on.  If  the  error  m essage  rem ains,  please  contact  Custom er  Service  for  further 
assistance.

BATTERIES

 

The thermometer incorporates visual low battery indication as follows: 

‘Battery OK’: 

m easurements 

are pos sible 

‘Battery Low’: battery needs to 

be replaced, measurem ents 

are possible 

‘Battery Exhausted’: 

measurements are 

not possible