Sussex VSMQ-60 - User Manual

Sussex VSMQ-60

Sussex VSMQ-60 Faucet – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

2

SUSSEX

INFO & INST

ALL GUIDES

CONCEPTS

sussextaps.com.au

5.0

litres per

minute

Licence No. 0124

In accordance with AS/NZS 6400

Sussex Taps Pty Ltd

WATER RATING

www.waterrating.gov.au

The more

stars the more

water efficient

AS/NZS 3718:2005

LIC. 20081

Calibre

INFORMA

TION

SHEET

C a l i b r e B a s i n M i x e r

P r o d u c t c o d e : C B M

160

80

100

40

35

48

sussextaps.com.au

5.0

litres per

minute

Licence No. 0124

In accordance with AS/NZS 6400

Sussex Taps Pty Ltd

WATER RATING

www.waterrating.gov.au

The more

stars the more

water efficient

AS/NZS 3718:2005

LIC. 20081

Calibre

C a l i b r e B a s i n M i x e r

P r o d u c t c o d e :

Av a i l a b l e o p t i o n s :

C B M

B a s i n M i x e r

C E B M

E x t e n d e d B a s i n M i x e r

INST

ALLA

TION

GUIDE

P L U M B E R N O T E

- O n - s i te te s t i n g u s i n g h i g h e r w a te r p re s s u re s m u s t b e

c o n d u c te d w i t h t h e M i xe r i n t h e c l o s e d p o s i t i o n .
(S TAT I C T E S T )

- U n d e r n o c i rc u m s t a n c e s i s t h e M i xe r to b e o p e n e d

w h e n exc e e d i n g t h e m a x i m u m s t a t e d w a t e r p re s s u re .

- At t h e c o m p l e t i o n o f te s t i n g , d o n o t re l i e ve a ny h i g h

w a te r p re s s u re by o p e r a t i n g t h e M i xe r.

- E x p o s i n g t h e i n te r n a l s o f t h e M i xe r C a r t r i d g e to h i g h e r

t h a n s p e c i f i e d w a te r p re s s u re s w i l l vo i d t h e
m a n u f a c t u re r s w a r r a n t y.

I N S TA L L AT I O N G U I D E L I N E S

- T h e M i xe r i s s u p p l i e d a s s e m b l e d , o n l y t h e F i x i n g n u t

a n d t h e C l a m p n e e d to b e re m ove d .

- A f te r re m ov i n g t h e m e n t i o n e d p a r t s , l o w e r t h e M i xe r

o n to t h e m o u n t i n g s u r f a c e a n d f i t t h e F l ex i b l e H o s e s .

- I n s o m e c a s e s t h e F l ex i b l e H o s e s m ay n e e d to b e f e d

t h ro u g h f ro m u n d e r t h e m o u n t i n g s u r f a c e a n d t h e n
a t t a c h e d . ( T i g h t e n u s i n g a p p ro p r i a t e s p a n n e r)

- A f te r s e c u r i n g t h e F l ex i b l e H o s e s , f i t C l a m p a n d a t t a c h

t h e F i x i n g N u t f ro m u n d e r n e a t h .

- B e f o re f u l l y s e c u r i n g t h e M i xe r e n s u re t h a t t h e B a s e O

R i n g i s i n t a c t a n d t h e M i xe r i s p ro p e r l y c e n te re d ove r
t h e m o u n t i n g s u r f a c e h o l e .

- T h e M i xe r m o u n t i n g s u r f a c e m u s t b e c o m p l e te l y s e a l e d

a n d w a te r-t i g h t .

- T h e 1/ 2 ” F i t t i n g s o f t h e F l ex i b l e H o s e s h ave a c o n i c a l

s e a l , e n s u re t h a t t h e m a t c h i n g t h re a d s a re c u t s q u a re
a n d b u r r f re e .

- P r i o r to c o n n e c t i n g t h e F l ex i b l e H o s e s , e n s u re a l l

p i p e w o r k i s t h o ro u g h l y f l u s h e d a n d e n s u re p i p e w o r k i s
f re e o f a ny d i r t

o r d e b r i .

- I s o l a t i n g S to p Va l ve s a re re c o m m e n d e d w i t h a l l

i n s t a l l a t i o n s . (n o t s u p p l i e d )

- C o n n e c t t h e F l ex i b l e H o s e s to H o t a n d C o l d p i p e w o r k

f i t t i n g s , e n s u re t h e H o s e s d o n o t k i n k o r b e c o m e
t w i s te d

w h e n t i g h te n i n g .

- C h e c k a l l f i t t i n g s a n d c o n n e c t i o n s a re s e c u re a n d

w a t e r-t i g h t .

BASE

O-RING

CLAMP

Hole Size
32-35mm

50mm Max.

Bench thickness

1/2" BSP Fittings

with conical Seals

FLEXIBLE HOSES

FIXING

NUT

CONCEPT

One

7.5

litres per

minute

Licence No. 0124

In accordance with AS/NZS 6400

Sussex Taps Pty Ltd

WATER RATING

www.waterrating.gov.au

The more

stars the more

water efficient

Pin

Handle

Handle

Body

Sink Mixer

Body

Sink Mixer

Stand

32 - 35m m

Hose extension

(Do not remove)

Base Flange

Clamp

Fixing

Nu t

Surface

Flexible Hose

N O T E :

M i x e r h a n d l e

t o b e

R I G H T- H A N D

s i d e o f t h e o p e r a t o r.

Product code

Installation guidelines

Plumber note

Voda

- The Mixer is supplied assembled, only the Fixing nut and the Brass Clamp need to be removed.
- Decide if the Optional Base Flange is to be used.
- If using the Optional Base Flange discard the smaller Base O Ring.
- Add the base Flange to base of Mixer and attach the Flexible Hoses to the Mixer Hose extensions.
- In some cases the Flexible Hoses may need to be fed through from under the mounting surface and then attach.
- Once the Flexible Hoses have been secured, lower the Mixer onto the mounting surface.
- Working from underneath the mounting surface fit Clamp and Fixing Nut.
- Before fully securing the Mixer ensure that the Base O Ring is intact and the Mixer is centered over the mounting

surface hole .

- The Mixer mounting surface must be completely water-tight.
- Connect the Hot and Cold Flexible hoses to the corresponding 1/2”BSP water feed lines.
- The 1/2” connection of the Flexible hoses have a conical seal, ensure the mating threads are cut square and burr

free.

- Isolating stop valves are recommended with all installations. (not supplied)
- Ensure all fittings and connections are water-tight.

Note:

Optional Base Flange must be used when the clearance hole for mounting the Mixer exceeds 35mm. If the

mounting hole clearance exceeds 45 mm a custom made Base flange will be required.

- On-site testing using higher water pressures must be conducted with the Mixer in the closed position.

(STATIC TEST)

- Under no circumstances is the Mixer to be opened when exceeding the maximum stated water pressure.
- At the completion of testing, do not relieve any high water pressure by operating the Mixer.
- Exposing the internals of the Mixer Car tridge to higher than specified water pressures will void the

manufacturers warranty.

VSM

Sink mixer

VSMC

Sink mixer curved

VSMQ

Sink mixer square

VSMCSSRH

Sink mixer curved 316 S/S

VSMQSSRH

Sink mixer square 316 S/S

Sink mixer

sussextaps.com.au

Tapware is to be installed by a Licensed Plumber in accordance with AS/NZS 3500:2003

Recommended working water pressure 300-500 kpa. Maximum water temperature is 65 deg.c

Copyright © Sussex Taps.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Sussex Faucets Models

All Sussex Faucets