Superior UVFR-500 - Manual
Superior UVFR-500 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 3 – Determine the volume of space — ft; ft; Divide the volume of space by 50 ft; to; CODES; all operating appliances in the space.
- Page 4 – LOCATION OF FIREBOX; Figure 1 for location suggestions.; Clearances; Ensure the minimum clearances shown in; Figure 2; Not to Scale
- Page 5 – ASSEMBLY STEPS; Figure 3; Consult all local codes.
- Page 6 – Construct firebox framing following
- Page 7 – Firebox Installation; Figures 6 through 10; UVF-600 SPECIFICATIONS
- Page 8 – FRAMING SPECIFICATIONS; Figure 6; Framing Dimensions
- Page 9 – Step 3. Replace the screws previously removed.; OPTIONAL EQUIPMENT; Circulating Models Only; Canopy Installation; Figure 9; Blower Kit Installation; Blower Motor
- Page 10 – ACCESSORIES AND COMPONENTS; Decorative Volcanic Stone
- Page 11 – REPLACEMENT PARTS; DESCRIPTION; Gas Fireplace Assembly
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE.
1
36" & 42" Unvented Fireboxes
P/N 700,018M REV. C 12/2003
UVFR-500
UVFC-500
UVFR-600
UVFC-600
MODELS
STANDARD SERIES
INSTALLATION
INSTRUCTIONS
FOR USE ONLY WITH DECORATIVE TYPE UNVENTED ROOM
HEATERS.
DO NOT BUILD A WOOD FIRE.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
FOR YOUR SAFETY: Do not store or use gasoline
or other flammable vapors or liquids in the vicinity
of this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the
fire department.
Installation and service must be performed by a
qualified installer, service agency or the gas sup-
plier.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
WARNING: IMPROPER INSTALLATION, ADJUSTMENT, AL-
TERATION, SERVICE OR MAINTENANCE CAN CAUSE IN-
JURY OR PROPERTY DAMAGE. REFER TO THIS MANUAL.
FOR ASSISTANCE OR ADDITIONAL INFORMATION CON-
SULT A QUALIFIED INSTALLER, SERVICE AGENCY OR THE
GAS SUPPLIER.
WARNING: DO NOT BURN WOOD OR OTHER MATERIAL IN
THESE APPLIANCES.
CAREFULLY REVIEW THE INSTRUCTIONS SUPPLIED WITH
THE DECORATIVE TYPE UNVENTED ROOM HEATER FOR
THE MINIMUM FIREPLACE SIZE REQUIREMENT.
DO NOT INSTALL THE APPLIANCE IN THIS FIREBOX, UN-
LESS THIS FIREBOX MEETS THE MINIMUM DIMENSIONS
REQUIRED FOR THE INSTALLATIONS.
This is an unvented gas-fired heater. It uses air
(oxygen) from the room in which it is installed.
Provisions for adequate combustion and ventila-
tion air must be provided. Refer to Combustion
and Ventilation Air Section, Page 3.
Due to high temperatures, the appliance should be located out
of traffic and away from furniture or draperies.
Do not place clothing or other materials on or near this appli-
ance.
IMPORTANT: READ AND UNDERSTAND THESE INSTRUCTIONS
COMPLETELY BEFORE INSTALLING YOUR UNVENTED ROOM
HEATERS.
UVFC-600
UVFR-500
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 3 Use the following equations to determine ifyou have a confined or unconfined space. 1. Determine the volume of space — ft 3 . Length x Width x Height = _____ ft 3 (Include adjoining rooms with doorless pas-sageways or ventilation grills betweenrooms....
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 4 WARNING: IF THE AREA IN WHICH THEHEATER MAY BE OPERATED IS SMALLERTHAN THAT DEFINED AS AN UNCON-FINED SPACE, PROVIDE ADEQUATECOMBUSTION AND VENTILATION AIR BYONE OF THE METHODS DESCRIBED INTHE NATIONAL FUEL GAS CODE, ANSIZ223.1 1992, SECTION 5.3 OR A...
NOTE: DIAGRAMS & ILLUSTRATION NOT TO SCALE. 5 Install only a ¹⁄₂ " (1 ¹⁄₂ " max.) inside diameter approved gas line through the firebox wall forconnection to the unvented room heater insidethe firebox. Ensure that a sediment trap is installed in theexisting gas line, if not, install a se...