Superior SSDVPF-CNE-B - Manual

Superior SSDVPF-CNE-B

Superior SSDVPF-CNE-B – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
Page: / 40

Table of Contents:

  • Page 2 – TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION
  • Page 3 – 0 - latest edition, or the Canadian Electrical; Table 1
  • Page 4 – Table 3; Flame Height; SIT Millivolt Gas Valve; NOTE: Flame appearance will diminish 4% per; REQUIREMENTS FOR THE COMMON-; Table 5
  • Page 5 – Figure 3 - Typical Locations; Do not insulate the space between the ap-
  • Page 6 – VENT TERMINATION CLEARANCES; These instructions should be used as a; Vertical Vent Termination Clearances; Termination Heights For Vents; Figure 5; Horizontal Vent Termination Clearances; Side Elevation View; Minimum; Figure 4A - Multiple Terminations
  • Page 7 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS; Figure 6; Minimum Clearances
  • Page 8 – MINIMUM CLEARANCES TO COMBUSTIBLES; When the; inclined vent component.; Table 6; The material must; . Maintain the minimum height from appliance base to the underside; Figure 7
  • Page 9 – DETAILED INSTALLATION STEPS; Removing Glass Panels on Page 30.
  • Page 11 – FLUE; Model
  • Page 12 – Proper Sizing of Gas Line; Table 7; Step 2. ROUTING GAS LINE
  • Page 13 – The VENT SEAL CAP must remain securely installed; Note: The restrictor is included within the firebox.; Step 3. INSTALL THE VENT SYSTEM; Approved Vent; on
  • Page 14 – Table 8; and 18) and their associated Vertical Vent Tables
  • Page 17 – Ratio V to H ratio is 1:2; VERTICAL VENT FIGURES/TABLES; rate sections of concentric flexible
  • Page 18 – Top Vent - THREE ELBOWS; Ceiling
  • Page 19 – to Figure 20 on; See; appliance collar. Attach in the same manner
  • Page 20 – Termination Guard
  • Page 21 – Under no circumstances, may separate sections of; Square termination; Termination Kit Only; Table 9; HORIZONTAL VENT FIGURES/TABLES
  • Page 23 – Figure 4
  • Page 24 – SECuRE FLEX
  • Page 25 – Millivolt Wiring Diagram; Verify proper operation after servicing.; CAUTION; (See Figures 45 and
  • Page 26 – Valve Access Side; CAUTIONS; IMPORTANT NOTE; Connect the ground supply wire to the green; Note: The supplied 15 feet of 2 conductor
  • Page 27 – Step 6. CONNECTING GAS LINE; CONTROL COMPARTMENT ACCESS/LOUVER; NOTE: The top louvered panel and the bottom; Lower Control; Gas
  • Page 28 – STONE AND GLOWING EMBERS; Note: Using a soapy water solution is an effec-
  • Page 29 – BURNER POSITIONING; Volcanic Stone; Figure 53. This procedure is accomplished; Bag of Glowing
  • Page 30 – Note: When installing the glass door, ensure the
  • Page 31 – 7 (adjustment rod is located in the lower; Combustible Wall Framing; - Burner Air Shutter Adjustment; HOOD INSTALLATION; All of these appliances must have hoods; FINISHING REQUIREMENTS; See Page 5 for Cold Climate Insula-; WARNINGS; Burner Air Shutter Adjustment Procedure; Figure 58 - Burner Flame Appearance
  • Page 32 – APPOSITION DES MISES EN GARDE RELATIVES; LENNOX HEARTH PRODUCTS; COLOCACIóN DE ADVERTENCIAS DE; LENNOX HEARTH PRODUCTS; Figure A
  • Page 33 – INSTALLATION ACCESSORIES
  • Page 34 – Open Top Shroud Kits; Closed Top Shroud Termination Kits
  • Page 35 – this installation assumes responsibility for this conversion.; AVERTISSEMENT; assume les responsabilités liées à la conversion.
  • Page 36 – All Models; NOTE: Each model has two burners and 2; Note: If the igniter is damaged, a replacement kit; Electronic Appliances; Figure 63 and the instructions provided with
  • Page 37 – BURNER; ALWAYS TEST PRESSURES WITH THE VALVE
  • Page 38 – NOTES
Loading the manual

OTL Report No. 116-F-32-5

US

Portland

MODELS

This appliance may be installed in an aftermarket permanently located, manufactured home (USA only) or mobile

home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating

plate. This appliance is not convertible for use with other gases unless a certified kit is used.

INSTALLATION INSTRUC

TIONS

SSDV Direct-Vent

Gas Fireplaces

MILLIVOLT:

ELECTRONIC:

P/N 700031M Rev. F 01/2011

This manual is one of a set of two supporting this product.

Refer to P/N 725035M for Care and Operation Instructions.
Ce manuel est disponible en francais, simplement

en faire la demande. Numéro de la pièce 700031CF.

AVERTISSEMENT : Assurez-vous de bien suivre les

instructions données dans cette notice pour réduire au

minimum le risque d’incindie ou d’explosion ou pour

éviter tout dommage matériel, toute blessure ou la mort.

- Ne pas entreposer ni utilizer d’essence ni d’autres vapeurs

ou liquides inflammables dans le voisinage de cet appareil

ou de tout autre appareil.

- QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ :

• Ne pas tenter d’allumer d’appareil.
• Ne touchez à aucan interrupteur. Ne pas vous servir des

téléphones se trouvant dans le bâtiment où vous trouvez.

• Appelez immédiatement votre fournisseur de gaz depuis

un voisin. Suivez les instructions du fournisseur.

• Si vous ne pouvez rejoindre le fournisseur de gaz,

appelez le service des incindies.

- L’installation et l’entretien doivent être assurés par un

installateur ou un service d’entretien qualifié ou par le

fournisseur de gaz.

WARNING: If the information in these instructions

is not followed exactly, a fire or explosion may

result, causing property damage, personal injury,

or death.

-

vapors and liquids in the vicinity of this or any other

appliance.

- WHAT TO DO IF YOU SMELL GAS:

• Do not try to light any appliance.

• Do not touch any electrical switch; do not use any

phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s

instructions.

department.

- Installation and service must be performed by a

WARNING / AVERTISSEMENT / AVISO

• HOT GLASS WILL CAUSE

BURNS.

• DO NOT TOUCH GLASS

UNTIL COOLED.

• NEVER ALLOW CHILDREN

TO TOUCH GLASS.

• UNE SURFACE VITRÉE CHAUDE

PEUT CAUSER DES BRÛLURES.

• LAISSER REFROIDIR LA SURFACE

VITRÉE AVANT D'Y TOUCHER.

• NE PERMETTEZ JAMAIS À UN ENFANT

DE TOUCHER LA SURFACE VITRÉE.

• EL VIDRIO CALIENTE

CAUSARÁ QUEMADURAS.

• USTED DEBE NUNCA

TOCAR EL VIDRIO CALIENTE.

• LOS NIÑOS DEBEN NUNCA

TOCAR EL VIDRIO.

INSTALLER:

Leave this manual with the appliance.

CONSUMER:

Retain this manual for future reference.

INSTALLATEUR :

Laissez cette notice avec l'appareil.

CONSOMMATEUR :

Conservez cette notice pour

consultation ultérieure.

SSDVST-CNM-B

SSDVST-CNE-B

SSDVPF-CNM-B

SSDVPF-CNE-B

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - TABLE OF CONTENTS; Please read and understand these; WARNING; GENERAL INFORMATION

2 TABLE OF CONTENTS Packaging .........................................Page 2Introduction ......................................Page 2General Information ..........................Page 2Requirements for the Commonwealth of Massachusetts .Page 4New York City Approval .....................Page 4Cold C...

Page 3 - 0 - latest edition, or the Canadian Electrical; Table 1

3 The appliance, when installed, must be electri- cally grounded and wired in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70 - latest edition, or the Canadian Electrical Code, CSA C22.1 - latest edition. Provide adequate clearances arou...

Page 4 - Table 3; Flame Height; SIT Millivolt Gas Valve; NOTE: Flame appearance will diminish 4% per; REQUIREMENTS FOR THE COMMON-; Table 5

4 NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 4 Gas Pressure - All Models Tables 3 and 4 show the appliances' gas pressure requirements: Inlet Gas Supply Pressure (all models) Fuel # Minimum Maximum Natural Gas 5.0" WC (1.24 kPa) 10.5" WC (2.61 kPa) Propane 11.0" WC (2.74 kPa) 1...

Other Superior Models

All Superior Other