Table of Contents:
- Page 2 – TABLE OF CONTENTS; Please read and understand these; Millivolt; PACKAGING; Approved Vent Components; Manufactured Home Requirements; WARNING; GENERAL INFORMATION; Installation and repair should be per-; The use
- Page 3 – greater; by closing their; less than; Table 7; Table; show the appliances' gas; the electronic gas control valve.; See; Manifold Pressure Tap
- Page 4 – Requirements for the Commonwealth of Massachusetts; “GAS VENT DIRECTLY
- Page 5 – SAFETY & WARNIING INFORMATION
- Page 6 – Do; Figure 8; Figure 3; Typical Locations
- Page 7 – VENT TERMINATION CLEARANCES; Figure 4; Horizontal Vent Termination Clearances; Figure 5; Side Elevation View; Horizontal Vent Termination Clearances; • Manufactured Home Construction and; CAUTIONS
- Page 8 – EXTERIOR HORIZONTAL VENT TERMINATION CLEARANCE REQUIREMENTS
- Page 9 – MINIMUM CLEARANCES TO COMBUSTIBLES; Figure 9; for clearance
- Page 10 – TYPICAL INSTALLATION SEQUENCE; Pressure Relief Plates; Left side installation is optional (see Figure 13); STEP 2. ROUTING GAS LINE; on; DETAILED INSTALLATION STEPS; Remove the cardboard from; DO NOT
- Page 11 – FIREPLACE SPECIFICATIONS; Vent Size; Notes; Model A; Top View; Right Side View; Hood; Front View; C is the required framing depth; Product Reference Information
- Page 12 – Proper Sizing of Gas Line; Table 9; FIREPLACE FRAMING SPECIFICATIONS
- Page 13 – for
- Page 14 – and their associated
- Page 15 – Dimple; An elbow may also be attached to the; Blocking
- Page 17 – A Vent Restrictor, as shown in; Ratio V to H ratio is 1:2; VERTICAL VENT FIGURES/TABLES; Secure Vent
- Page 18 – ) horizontal run up to a; Top Vent - THREE ELBOWS
- Page 19 – refer to Figure
- Page 20 – IMPORTANT; Termination Guard; Page 32. This can be
- Page 21 – HORIZONTAL VENT FIGURES/TABLES; Termination Kit Only; Table G
- Page 22 – Wall; to a maximum horizontal run of 20 feet.
- Page 23 – Ceiling
- Page 24 – SECURE FLEX
- Page 25 – Step 4. FIELD WIRING; A. SIT Millivolt Wiring; Figures; WIRING - OPTIONAL FORCED AIR; B. Electronic Wiring; Note: If any of the original wire as supplied must be replaced,
- Page 26 – Step 6. CONNECTING GAS LINE; Figure; Schematic Representation Only; Gas Flex Line Connector; GAS CONNECTION; CAUTION
- Page 27 – Sit Millivolt Pilot Assembly; Using a soapy water solution; Removing Control Compartment Door:; SIT Millivolt Appliance Checkout; Control Compartment
- Page 28 – Glowing Embers; Bag of Glowing; Remove the front glass enclosure panel; Handle logs carefully to prevent; Mound; Placement of Glowing Embers -; Keep the pieces fl uffed up, not matted.; Electronic Pilot Assembly; Electronic Appliance Checkout
- Page 29 – Firebox Accessories / Parts; LOG SET; Log Installation Instructions (refer to Figure 52)
- Page 30 – Reinstalling Control
- Page 31 – Main Burner Factory Air Shutter; HOOD INSTALLATION; Page 6; Cold Climate Insulation; and; Clearances; Burner Air Shutter Adjustment Procedure
- Page 32 – INSTALLATION ACCESSORIES
- Page 33 – Open Top Shroud Kits; Closed Top Shroud Termination Kits
- Page 34 – GAS CONVERSION KITS
- Page 36 – Burner Orifi ce; Pilot Assembly
OTL Report No. 116-F-05-5
INSTALLATION
INSTRUCTIONS
Millivolt Models
Electronic Models
MODELS
P/N 700,041M REV. B 11/2006
DIRECT VENT GAS FIREPLACE HEATERS
DIRECT VENT
SDDV-35/40 SERIES
SDDV-35NM
SDDV-35PM
SDDV-40NM
SDDV-40PM
SDDV-35NE
SDDV-40NE
A French manual is available upon request. Order P/N 700,041CF
Ce manuel d’installation est disponible en francais, simplement en
faire la demande. Numéro de la pièce 700,041CF.
In the Commonwealth of Massachusetts:
•
Installation must be performed by a licensed plumber or
gas fi tter;
• See Table of Contents for location of additional Com-
monwealth of Massachusetts requirements.
This appliance may be installed as an OEM in-
stallation in a manufactured home (USA only) or
Manufactured Home and must be installed in ac-
cordance with the manufacturer's instructions and
the manufactured home construction and safety
standard,
Title 24 CPF, Part 3280
or Standard for
Installation in Manufactured Homes, CAN/CSA Z240
MH.
This appliance is only for use with the type(s)
of gas indicated on the rating plate. A conversion
kit is supplied with the appliance.
RETAIN THESE INSTRUCTIONS
FOR FUTURE REFERENCE
FOR YOUR SAFETY: Do not store or use gasoline
or other fl ammables or liquids in the vicinity of
this or any other appliance.
FOR YOUR SAFETY: What to do if you smell gas:
• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• Do not use any phone in your building.
• Immediately call your gas supplier from a
neighbor’s phone. Follow your gas suppliers
instructions.
• If your gas supplier cannot be reached, call
the fi re department.
Installation and service must be performed by
a qualifi ed installer, service agency or the gas
supplier.
WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO-
SION MAY RESULT CAUSING PROPERTY DAMAGE,
PERSONAL INJURY OR LOSS OF LIFE.
POUR VOTRE SÉCURITÉ: Ne pas entreposer ni
utiliser d'essence ni d'autre vapeurs ou liquides
infl ammables dans le voisinage de cet appareil ou
de tout autre appareil.
POUR VOTRE SÉCURITÉ: Que faire si vous sentez
une odeur de gaz:
• Ne pas tenter d'allumer d'appareil.
• Ne touchez à aucun interrupteur. Ne pas vous
servir des téléphones se trouvant dans le bati-
ment où vous vous trouvez.
• Evacuez la piéce, le bâtiment ou la zone.
• Appelez immédiatement votre fournisseur de
gaz depuis un voisin. Suivez les instructions du
fournisseur.
• Si vous ne pouvez rejoindre le fournisseur de
gaz, appelez le service dos incendies.
L'installation et service doit être exécuté par un
qualifi é installeur, agence de service ou le fournis-
seur de gaz.
AVERTISSEMENT: ASSUREZ-VOUS DE BIEN
SUIVRE LES INSTRUCTIONS DONNÉ DANS CETTE
NOTICE POUR RÉDUIRE AU MINIMUM LE RISQUE
D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE
MATÉRIEL, TOUTE BLESSURE OU LA MORT.
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 2 TABLE OF CONTENTS Packaging ......................................... Page 2Introduction ...................................... Page 2General Information .......................... Page 2New York City Approval ..................... Page 3Require...
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 3 New York City, New York (MEA) Installation of these fi replaces are approved for installation in New York City in the US state of New York. These appliances and their individual shut-off valves must be disconnected from the gas supply piping sys...
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE. 4 Note: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every ...