Table of Contents:
- Page 3 – LEAKAGE TEST; multimeter is suitable for this job.
- Page 5 – -5. Packing Materials for Media Receiver Unit; ELECTRICAL PARTS LIST
- Page 6 – • I t e m s w i t h n o p a r t n u m b e r a n d n o; The components identified
- Page 9 – B BLOCK ASSY
- Page 14 – RESISTORS
- Page 100 – Sony EMCS Corporation
SERVICE MANUAL
SPECIFICATIONS
KE-50XBR900
FLAT PANEL COLOR TV
US Model
Canadian Model
Panel System
Plasma Display panel
Display resolution
Display resolution:
1365 pixels (horizontal)
×
768 pixels (vertical)
Antenna
75 ohm external terminal for VHF/UHF
Television System
NTSC, American TV Standard
Channel Coverage
VHF
2-13
UHF
14-69
CATV
1-125
Power Requirements
120V, 60 Hz
Inputs/Outputs
DVI-HDTV
1 terminal, 3.3V T.M.D.S., 50 ohms
The DVI-HDTV input terminal is compliant with the EIA-861 standard and is not
intended for use with personal computers.
Video (IN)
3 total (1 on front panel)
1 Vp-p, 75 ohms unbalanced, sync negative
S Video (IN)
(1 on front panel)
Y: 1 Vp-p, 75 ohms unbalanced, sync negative
C: 0.286 Vp-p (Burst signal), 75 ohms
Audio (IN)
(1 on front panel)
500 mVrms (100% modulation)
Impedance: 47 kilohm
Component Video Input
2 (Y, P
B
, P
R
)
Y: 1.0 Vp-p, 75 ohms unbalanced, sync negative;
P
B
: 0.7 Vp-p, 75 ohms
P
R
: 0.7 Vp-p, 75 ohms
CONTROL S (OUT)
Variable/Fixed Audio (OUT)
More than 408 m Vrms at the maximum volume
setting (Variable)
More than 408 mVrms (Fixed)
Impedance (output): 2 kilohms
Monitor/Fixed Audio (OUT)
×
1
1
1
3 total
6 total
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
KE-50XBR900(UC) 3 LEAKAGE TEST The AC leakage from any exposed metal part to earth ground and from allexposed metal parts to any exposed metal part having a return to chassis,must not exceed 0.5 mA (500 microamperes).Leakage current can be measured by any one of three methods.1. A commercial leakage...
KE-50XBR900(UC) 5 1. EXPLODED VIEWS 1-1. Display Unit (PDM-5000) ................................... 1-2 1-2. Media Receiver Unit-1 (MBT-XBR900) ............. 1-4 1-3. Media Receiver Unit-2 (MBT-XBR900) ............. 1-6 1-4. Packing Materials for Display Unit (PDM-5000) ...............................
KE-50XBR900(UC) 1-1 SECTION 1 EXPLODED VIEWS • I t e m s w i t h n o p a r t n u m b e r a n d n o description are not stocked because theyare seldom required for routine service. • The construction parts of an assembled part are indicated with a collation numberin the remark column. • Items marked ...