PACKAGE CONTENTS

Section 1 - Setting up the Wall Switch Receiver

2.

Install the Wall Switch with the 3 wires, Live, Load and Ground. Use the provided

wire nuts (C) to connect these wires respectively to the existing wires from the wall.

Neutral wire is not required and cannot be connected to the Wall Switch Receiver.

1.

Loosen the screws on the wallplate cover of the Wall Switch receiver and

remove it before installing.

Turn off power to the circuit breaker before installing.
If you are uncertain or uncomfortable performing this installation, please consult
a qualified electrician. This manual should also be kept for future reference.
For indoor use only.
DO NOT use this product to control loads over the specified maximum rating.
For dimming function, the light bulbs must be dimmable.

The device is approved by the FCC and it complies with Part 15 of the FCC Rules.

Its operation is subject to the following two conditions:

1. This device may not cause harmful interference.

2. This device must accept any interference that may cause undesired operation.

Technical Specifications:

3.

After all the wires are connected, ensure that all of the wire connectors are

attached securely and there should be no exposed copper wiring. Secure the

Wall Switch with screws.

4.

Make sure the air gap switch is in the off position and then turn the circuit back on.

5.

Place the air gap switch to on position. The two blue LEDs will be on. If the blue

LEDs remain off, please check and ensure the light bulb is installed and in good

position and that the wires are connected correctly.

6.

After the Wall Switch is installed, tap the metal touch plate to turn the lights on

and off.

Congratulations on your purchase of the SkylinkHome

TM

Wireless 3 Way On/Off/

Dimmer Kit, model SK7. Simply replace your existing wall switch with the

Skylink Wall Switch receiver and mount the Wireless Wall Switch Transmitter

anywhere you would like to control your lighting.

INSTALLATION INSTRUCTIONS

WIRELESS 3 WAY ON/OFF/DIMMER KIT

Model: SK7

Safety Information

Technical Specifications

WARNING:

Turn off power to the circuit that you plan on installing the Wall Switch to, at

the circuit breaker. Failure to turn off power at the circuit breaker can result in electrical

shock, causing severe or fatal injury.

Warranty

Package Contents

ONE YEAR WARRANTY

This product is guaranteed to be free of defects in materials and workmanship for

1 year from the date of purchase. If this product is defective, call 1-800-304-1187 for

repair or replacement parts. Guarantee does not include normal wear and tear or

batteries.

If you have any questions, problems or missing parts,

please call Skylink Customer Support:

9:00am - 5:00pm EST, Monday-Friday.

Or e-mail us at [email protected]

P/N : 101Y156 Rev:0

©2014 SKYLINK GROUP.

CUSTOMER SERVICE

17 Sheard Avenue,

Brampton, Ontario,

Canada L6Y1J3

1-800-304-1187

www.skylinkhome.com

A

B

1.

First clean the wall surface where you plan to install the Wireless Wall Switch

transmitter.

2.

Place the two foam tapes (E) on the back of the Wireless Wall Switch transmitter

plate.

3.

Peel off the foam tape cover and stick it to the wall surface.

Section 2 - Setting up the Wireless Wall Switch Transmitter

NOTE:

The Wireless Wall Switch Transmitter comes with a lithium battery already installed.

Remove the battery isolator tag from the Wireless Wall Switch transmitter before installing.

NOTE:

The Wall Mount transmitter comes with a lithium battery already installed. Remove

the battery isolator tag from the Wall Mount Transmitter before installing.

NOTE:

The Wall Switch is designed to operate incandescent light or dimmable compact

fluorescent light with a maximum load of 300W at 120VAC. Light bulbs must be dimmable

in order to achieve dimming function.

NOTE:

If you already have an existing 3 Way Switch, disable one switch and replace the

other switch with the Wall Switch Receiver.

D

D

D

Red

Load

Black

Live

Air Gap

Switch

ON Position

OFF Position

Blue

Touch Plate

LEDs

Grey Antenna

Green

Ground

Place

double-sided

foam tape

Existing Wall Box (No Anchor)

Drill 2 pilot holes

& insert anchors

INSTALLING WITH DOUBLE SIDED TAPE

INSTALLING WITH SCREWS

NOTE:

Make sure the Air Gap Switch is in the on position before you start.

Wall Switch Receiver

Installing to an Existing Wall Switch

Installing on New Wall Surface

1.

Loosen the screws on the wallplate cover of the Wireless Wall Switch transmitter

and tighten the two included screws (D) on the back plate to the existing wall

box.

2.

Tighten the two screws on the wallplate to the back plate to secure it.

3.

The Wireless Wall Switch transmitter is now ready to be controlled.

3.

The Wireless Wall Switch transmitter is now ready to be controlled.

2.

Tighten the two screws on the wall plate to the back plate to secure it.

1.

Drill two small pilot holes based on the two mounting screw positions and

insert the anchors (D) before tightening the back plate with screws (D).

Section 2 - Setting up (continued)

Section 3 - Operation

1.

To turn the light on and off, tap the Wall Switch metal touch plate..

2.

To dim or brighten the lights, tap the metal touch plate to turn on the lights

then press and hold to dim or brighten the lights.

Wireless Wall Switch Transmitter

1.

To turn the light on and off, push the Wireless Wall Switch pad from one

position to the other.

2.

To dim or brighten the lights, push the Wireless Wall Switch pad to turn on the

lights then press and hold the same (upper) pad to dim or brighten the lights.

Press and hold

Push

Push

Press and hold the

touch plate

Tap the touch plate

(Dimming)

(On/Off)

Part

Description

Quantity

A

Wall Switch Receiver

1

B

Wireless Wall Switch Transmitter

1

C

Wire Nuts

3

D

Screws and anchors

2

E

Double-sided Foam Tape

2

C

D

E



Input Voltage

120V AC, 60Hz

Standby Current

0.2mA

Minimum Load

10W

Maximum Load

300W at 120VAC

Operating Frequency

318MHz

Operational Temperature

-4°F - 140°F (-20

°C - 60°C)

Humidity

5% - 95%

Range

Up to 500 feet in open area

WARNING:

Changes or modifications to this unit not expressly approved by the party

responsible of compliance could void the user’s atuhority to operate the equipment.

NOTE:

Do not cut the antenna.