Page 2 - In continuous display mode; P key; C o n t ro l e l e m e n t s a n d k e y f u n c t i o n s
Control elements: overview 1 Operating light (green) 2 Warning light (yellow) 3 Error warning light (red) 4 Stroke length adjuster 5 LCD display 6 UP key 7 DOWN key 8 P key 9 STOP/START key 10 i key 11 Relay output (optional) 12 Metering monitor socket 13 Float switch socket 14 External control sock...
Page 5 - Continuous display; Contact; JN; ”Contact”
i i i i i i i i i i i i i i i i i i i i i i i i i i i # N * Mem Contact Stop Operating mode " Analog " 0-20 mA Str oke rate Feed rate To tal str oke number To tal litr es (feed quantity) "Exter nal" display Signal curr ent Str o kes r e maining Batch size/ Litr es r e maining Factor ...
Page 6 - Dulcodes UV-Desinfektionsanlage; Operating Instructions for ProMinent; I m p r i n t
Page 6 Pr o Minent ® Dulcodes UV-Desinfektionsanlage I m p r i n t Operating Instructions for ProMinent ® Sigma/ 2 S2Ba/S2Ca © ProMinent Dosiertechnik GmbH, 2002 ProMinent Dosiertechnik GmbHIm Schuhmachergewann 5-1169123 Heidelberg · [email protected] Subject to technical modi...
Page 7 - Pr; Ta b l e o f c o n t e n t s; N o t e s o n s a f e t y o f P ro M i n e n t
Dulcodes UV-Desinfektionsanlage Page 7 Pr o Minent ® Ta b l e o f c o n t e n t s Page Device Identification/Identcode 9 1 N o t e s o n s a f e t y o f P ro M i n e n t ® m e t e r i n g p u m p s 1 1 1.1 Summary of additional safety instructions for the EX versionof the pump (in accordance with AT...
Page 9 - I d e n t c o d e o r d e r i n g s y s t e m; S 2 B a; Liquid end materials:
Dulcodes UV-Desinfektionsanlage Page 9 Pr o Minent ® Dulcodes UV-Desinfektionsanlage I d e n t c o d e o rd e r i n g s y s t e m Pr o Minent ® I d e n t c o d e o r d e r i n g s y s t e m Please enter the identcode on the device label into the grey box below. S 2 B a S i g m a B a s i c T y p e ( ...
Page 10 - S 2 C a
Page 10 Pr o Minent ® Dulcodes UV-Desinfektionsanlage I d e n t c o d e o rd e r i n g s y s t e m I d e n t c o d e o r d e r i n g s y s t e m Please enter the identcode on the device label into the grey box below. S 2 C a S i g m a C o n t r o l T y p e ( S 2 C a ) HM Power end, diaphragm Pump ty...
Page 11 - NOTE; Notices are intended to make your work easier.; WARNING; • All other uses or modifications are prohibited!
Dulcodes UV-Desinfektionsanlage Page 11 Pr o Minent ® N o t e s o n s a f e t y o f P ro M i n e n t ® m e t e r i n g p u m p s 1 N o t e s o n s a f e t y o f P ro M i n e n t ® m e t e r i n g p u m p s G e n e r a l u s e r i n s t r u c t i o n s Please read through the following user instructi...
Page 13 - Safety devices; Because of danger of electrostatical; damp; cloth only; ATTENTION; EC conformity declaration / certificates; G e n e r a l n o t e s; N o t e s o n i n s t a l l a t i o n , s t a r t - u p a n d o p e r a t i o n
Dulcodes UV-Desinfektionsanlage Page 13 Pr o Minent ® Safety devices The following safety notice must be affixed to the pump (with PP, PC and PV liquid ends, acrylicglass cover, ...) Because of danger of electrostatical ignition use damp cloth only for wiping plastic parts! ATTENTION EC conformity d...
Page 14 - IMPORTANT; N o t e s o n m a i n t e n a n c e a n d r e p a i r
Page 14 Pr o Minent ® Dulcodes UV-Desinfektionsanlage IMPORTANT • Set stroke length only with pump in operation! • Pull the red plug for venting the gear unit during initial operation of the Sigma/ 2 metering pump (refer to Fig. 2, item 10)! NOTE • The pump must be secured in such a way that no vibr...
Page 15 - P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a; Use for intended purpose; I d e n t i f i c a t i o n o f p u m p t y p e
Dulcodes UV-Desinfektionsanlage Page 15 Pr o Minent ® P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a Fig. 1 2 P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a WARNING Use for intended purpose • The pump is designed as a liquid medium metering pump; it serves the purpose of metering liquid ...
Page 16 - S t r o k e m o v e m e n t; Set stroke length dependent on the required delivery capacity.
Page 16 Pr o Minent ® Dulcodes UV-Desinfektionsanlage 0 180 360 2 . 2 . 2 S t r o k e m o v e m e n t Set stroke length dependent on the required delivery capacity. P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a 5 6 3 7 1 8 4 10 Fig. 2 61_01-101_00_25-01 NOTE A large stroke length and low mete...
Page 17 - M e t e r i n g c a p a c i t y d i a g r a m
Dulcodes UV-Desinfektionsanlage Page 17 Pr o Minent ® Metering capacity diagram S2Ba HM (50 Hz) Str oke length in (%) pr essur e in (bar) Metering capacity diagram S2Ba HM (60 Hz) 2 . 2 . 3 M e t e r i n g c a p a c i t y d i a g r a m P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a Metering ca...
Page 19 - F u n c t i o n a l d e s c r i p t i o n , d e l i v e r y u n i t
Dulcodes UV-Desinfektionsanlage Page 19 Pr o Minent ® P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a Fig. 5 3154-4 2 . 2 . 4 F u n c t i o n a l d e s c r i p t i o n , d e l i v e r y u n i t The heart of the delivery unit is the DEVELOPAN ® metering diaphragm (2) . It hermetically seals the ...
Page 20 - I n t e g r a t e d o v e r f l o w v a l v e w i t h b l e e d e r f u n c t i o n; This function is produced by a spring-loaded ball.; Design and functional description; Overflow valve Sigma/ 2 liquid end, 10 bar PVT
Page 20 Pr o Minent ® Dulcodes UV-Desinfektionsanlage P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a 2 . 2 . 5 I n t e g r a t e d o v e r f l o w v a l v e w i t h b l e e d e r f u n c t i o n Task: The task of the overflow valve is to protect the motor and gear unit against impermissibleove...
Page 21 - Overflow valve Sigma/ 2 liquid end, 16 bar SST; Connection via hose connection item 128.
Dulcodes UV-Desinfektionsanlage Page 21 Pr o Minent ® Overflow valve Sigma/ 2 liquid end, 16 bar SST Identcode Type: 16050, 16090, 16130 Overflow valve Sigma/ 2 liquid end, 12 bar SST Identcode Type: 12050, 12090, 12130 Overflow valve Sigma/ 2 liquid end, 7 bar SST Identcode Type: 07120, 07220 Overf...
Page 22 - D i a p h r a g m r u p t u r e s e n s o r
Page 22 Pr o Minent ® Dulcodes UV-Desinfektionsanlage P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a Technical data Corresponding to the type of pump, overflow valves are available for pressure stages p nom 4, 7, 10, 12 and 16 bar with (1.05 ... 1.15) xp nom opening pressure. Material in conta...
Page 23 - electrical signal is given.; and/or ensure that the pump will stop after a diaphragm rupture.
Dulcodes UV-Desinfektionsanlage Page 23 Pr o Minent ® FM 130Identcode Type: 12050, 12090, 12130, 16050, 16090, 16130 FM 350Identcode Type: 04350, 07120, 07220 P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a The liquid end can continue to operate in emergency mode, i.e. full operating pressure, ...
Page 24 - Material in contact with metered medium; • The cable priority is arbitrary.; with the gasket (Item159) and make the electrical connections.
Page 24 Pr o Minent ® Dulcodes UV-Desinfektionsanlage P ro d u c t d e s c r i p t i o n S 2 B a / S 2 C a Material in contact with metered medium Liquid end: Parts of diaphragm failure monitor in contact with medium Lens, seals Intermediate disc Item 147, Item 148, 156, 159 intermediate bush Item 1...
Page 25 - T e c h n i c a l d a t a S i g m a / 2; Te c h n i c a l d a t a
Dulcodes UV-Desinfektionsanlage Page 25 Pr o Minent ® 3 Te c h n i c a l d a t a 3 . 1 T e c h n i c a l d a t a S i g m a / 2 3 . 1 . 1 C a p a c i t y d a t a Technical data S2Ba at 50 Hz operation Feed rate at Max. Suction Admissible Connection Shipping maximum stroke lift priming suction / weigh...
Page 27 - D i m e n s i o n s h e e t S i g m a / 2 w i t h s t r o k e a d j u s t m e n t m o t o r; * Dimensions for S2Ba; Model
Dulcodes UV-Desinfektionsanlage Page 27 Pr o Minent ® PVDF PP/PVC/PTFE SS Connection variations 3 . 1 . 3 D i m e n s i o n s h e e t S i g m a / 2 w i t h s t r o k e a d j u s t m e n t m o t o r Anschluss- varianten Fig. 10 61_01-101_00_39-73_2_HM Fig. 9 61_01-101_00_32-73 3 . 1 . 2 D i m e n s i...
Page 28 - M o t o r d a t a; S t r o k e a c t u a t o r d r i v e m e c h a n i s m
Page 28 Pr o Minent ® Dulcodes UV-Desinfektionsanlage Te c h n i c a l d a t a 230 V ± 10 % 50/60 Hz 11.7 W 115 V ± 10 % 60 Hz 11.7 W 230 V ± 10 % 50/60 Hz 6.5 W 115 V ± 10 % 60 Hz 6.5 W 3 . 1 . 4 M o t o r d a t a Electrical Data Motors: Identcode characteristic 3 ph IP 55 230 V/400 V 50 Hz 0.25 kW...
Page 29 - E l e c t r i c a l d a t a , p a c i n g r e l a y “ S i g m a ”
Dulcodes UV-Desinfektionsanlage Page 29 Pr o Minent ® Te c h n i c a l d a t a Blue - Brown + b) Namur sensor, intrinsically (Identcode characteristic “Stroke sensor”: 3) WARNING • EX-pump only: intrinsically safe installations must be installed and checked by persons with “recognised skills”! • EX-...
Page 30 - M a i n t e n a n c e
Page 30 Pr o Minent ® Dulcodes UV-Desinfektionsanlage 4 S t a r t - u p / M a i n t e n a n c e WARNING • For all metering pumps for metering inflammable media applies: Starting up and emptying only supervised by a competent person. IMPORTANT Observe the safety notes provided in Section 1. 4 . 1 S t...
Page 31 - The gear oil should be changed after approx. 5000 duty hours.; R e p l a c e m e n t o f w e a r i n g p a r t s; specially trained or authorised personnel!
Dulcodes UV-Desinfektionsanlage Page 31 Pr o Minent ® Maintenance intervals General recommendation for maintenance intervals - every 3 months. Shorter intervals are recommended if operated under load conditions (e.g. continuous operation). The gear oil should be changed after approx. 5000 duty hours...
Page 32 - first clean the ball and the ball seat disc.
Page 32 Pr o Minent ® Dulcodes UV-Desinfektionsanlage NOTE The tightening torque of the liquid end screws should be rechecked after 24 hours ofoperation. The tightening torques of the liquid end screws should be checked every 3 months for thePVT material version. S t a r t - u p / M a i n t e n a n ...
Page 33 - F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s; F u n c t i o n d e s c r i p t i o n , m o t o r s; F u n c t i o n d e s c r i p t i o n , c o n t r o l l e r; Operating modes; “Analogue” operating mode:; The stroke rate is controlled manually via the controller.; “Contact” operating mode:
Dulcodes UV-Desinfektionsanlage Page 33 Pr o Minent ® F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s 5 F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s 5 . 1 F u n c t i o n d e s c r i p t i o n , m o t o r s The pump has an integrated electronic overload cut-out in all versio...
Page 34 - “PROFIBUS
Page 34 Pr o Minent ® Dulcodes UV-Desinfektionsanlage F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s “PROFIBUS ® ” mode: (Identity code, control variant: PROFIBUS ® ) This operating mode provides the option of controlling the pump via the PROFIBUS ® (see “Supplementary instructions for P...
Page 35 - Prime; “Fault”, “stop” and “pause” stop all system parts up to “prime”.; S o c k e t s , s y m b o l s a n d w i r i n g d i a g r a m; (3) Metering monitor socket for connection of ProMinent
Dulcodes UV-Desinfektionsanlage Page 35 Pr o Minent ® F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s Hierarchy of operating modes, functions and fault statuses The different operating modes, functions and fault statuses each have a differing effect onwhether and how the S2Ca functions. T...
Page 36 - Pump type S2Ca
Page 36 Pr o Minent ® Dulcodes UV-Desinfektionsanlage F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s 2 1 4 green/NC white/NO brown/C pacing relay fault indicating relay yellow/NO white/NO green/NC brown/C 1 4 3 2 2 3 1 4 Technical data, relay (control version) Pump type S2Ca Relay Fault-...
Page 37 - Wiring diagram; View of cable connectors from front; Metering monitor cable; for; Diaphragm rupture cable; for
Dulcodes UV-Desinfektionsanlage Page 37 Pr o Minent ® Wiring diagram View of cable connectors from front Float switch cable for Universal signal cable (5-core) for Metering monitor cable for Diaphragm rupture cable for External/contact cable (2 core) for Contact open -> alarm-> pump stops with...
Page 38 - Technical data, external contact; Pin 2 = Contact input
Page 38 Pr o Minent ® Dulcodes UV-Desinfektionsanlage Technical data, external contact Semi-conductor switch elements (e.g. transistors in open-collector circuits) or contactors (relays)with a residual voltage of -0.7 V can be used as input switch elements. Controller type 0 (see identity code) Pin ...
Page 39 - Block circuit diagram S2Ca; I n p u t s
Dulcodes UV-Desinfektionsanlage Page 39 Pr o Minent ® Block circuit diagram S2Ca F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s I n p u t s P u m p , I n s i d e O u t p u t s GND External activation Diaphragm rupture sensor Metering monitor Level monitor Fault indicating relay warning M...
Page 40 - Circuit examples: universal signal cable; by customer Cable; “Pause“ function; External
Page 40 Pr o Minent ® Dulcodes UV-Desinfektionsanlage F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s Circuit examples: universal signal cable by customer Cable Pump, inside “Pause“ function Permanent contact,e.g. from control room “Auxiliary frequency“ function “External analogue“ functi...
Page 41 - R e t r o f i t t i n g r e l a y s; Press-out relay opening; not be less than 1.20 m long, otherwise cable recognition will fail.
Dulcodes UV-Desinfektionsanlage Page 41 Pr o Minent ® 5 . 4 R e t r o f i t t i n g r e l a y s (not in PROFIBUS ® version) Delivery range: 1 relay circuit set with 2 screw fasteners 1 relay cable set with socket 1 seal Press-out relay opening WARNING Disconnect the S3Ca from the mains power supply ...
Page 42 - Error; F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s / C o n t ro l e l e m e n t s; C o n t ro l e l e m e n t s; Indicators
Page 42 Pr o Minent ® Dulcodes UV-Desinfektionsanlage Set Flow Calib Mem Error Pause Aux Stop F e a t u re s o f t h e S 2 C a m e t e r i n g p u m p s / C o n t ro l e l e m e n t s Fig. 17 Fig. 18 6 C o n t ro l e l e m e n t s Please acquaint yourself with the S2Ca control elements with the help...
Page 43 - Basic information for setting up the S2Ca; continuous; S e t t i n g s
Dulcodes UV-Desinfektionsanlage Page 43 Pr o Minent ® 7 S e t t i n g s NOTE • Open out the fold-out page following the title page fully! There you will find the overviews “control elements and key functions” and “operating settings diagram”. • If no keys are pressed within a period of 1 minute, the...
Page 44 - S e l e c t o p e r a t i n g m o d e ( M O D E m e n u ); C h e c k a d j u s t a b l e v a l u e s; • MODE menu; In order to adapt the S2Ca to your process requirements you must:; Exception: Timer and PROFIBUS; Note the diagram below!; MODE
Page 44 Pr o Minent ® Dulcodes UV-Desinfektionsanlage 7 . 3 S e l e c t o p e r a t i n g m o d e ( M O D E m e n u ) The following operating modes are selected via the MODE menu (depending upon identitycode, some operating modes may be absent): • Manual: for operation by hand(Identity code, control...
Page 45 - S e t t i n g s f o r o p e r a t i n g m o d e ( S E T m e n u ); S e t t i n g s f o r “ m a n u a l ” o p e r a t i n g m o d e; You can select three signal-processing methods:
Dulcodes UV-Desinfektionsanlage Page 45 Pr o Minent ® S e t t i n g s • Contact: for contact operation(Identity code, control variant: external 1:1 / external with pulse control) • Batch: for batch operation(Identity code, control variant: external with pulse control) P Batch Contact Manual Analog A...
Page 46 - The following symbol appears in the LCD display:
Page 46 Pr o Minent ® Dulcodes UV-Desinfektionsanlage S e t t i n g s • 4 - 20 mA: at 4 mA the S2Ca does not operateat 20 mA the S2Ca operates at 180 strokes/min.Between these two extremes the stroke rate is proportional to the electricalsignal.For signals of below 3.8 mA a fault will be detected an...
Page 47 - Lower band; The symbol; S e t t i n g s f o r “ c o n t a c t ” o p e r a t i n g m o d e ( C O N T C T m e n u ); The factor resets to “1” if you change to a different operating mode.
Dulcodes UV-Desinfektionsanlage Page 47 Pr o Minent ® S e t t i n g s Lower/upper band: This processing mode allows you to control a pump via an electrical signal as shown in the diagrams below. Lower band Upper band e.g. Alkali pump e.g. acid pump I [mA] I 1 I 2 F2 F1 0 20 P1 P2 F max I [mA] I 1 I ...
Page 48 - Examples; Factor; Explanation of increase
Page 48 Pr o Minent ® Dulcodes UV-Desinfektionsanlage S e t t i n g s In the “contact - identity code: external with external pulse control” you can enter the numberof pulses after which a stroke should be carried out. “Contact - identity code: external withexternal pulse control” is intended for sm...
Page 49 - S e t t i n g s f o r “ b a t c h ” o p e r a t i n g m o d e ( B A T C H m e n u ); “Memory” extension function
Dulcodes UV-Desinfektionsanlage Page 49 Pr o Minent ® S e t t i n g s NOTE If a remainder occurs when the factor is processed, the S2Ca counts up the remaindervalues. When the sum reaches or exceeds “1” the S2Ca will activate a stroke. This ensuresthat the stroke number corresponds exactly to the fa...
Page 50 - nent display flashes and the flashing “Calib” indicator appears.; This will significantly affect accuracy of calibration.; S e t t i n g s f o r p r o g r a m m a b l e f u n c t i o n s ( S E T m e n u ); Flow (FLOW menu, available only if flow monitor is connected); S e t t i n g s f o r “ c a l i b r a t i o n ” f u n c t i o n ( C A L I B m e n u )
Page 50 Pr o Minent ® Dulcodes UV-Desinfektionsanlage P P P P P P Continuous display b i l a c Set n o Set Calib t r a t s Set Calib t i n u L Set 0 L Set Calib 2 3 2 4 t e s Set Calib N 0 0 2 The S2Ca can also run in calibration mode. The corresponding continuous displays show thecurrent dosing qua...
Page 51 - Settings for “auxiliary frequency” function (AUX menu); S e t t i n g s f o r t h e “ f l o w ” f u n c t i o n ( F L O W m e n u ); S e t t i n g c o d e ( C O D E m e n u ); C a n c e l t o t a l s t r o k e n u m b e r o r t o t a l l i t r e s ( C L E A R w i n d o w )
Dulcodes UV-Desinfektionsanlage Page 51 Pr o Minent ® S e t t i n g s 7.5.2 Settings for “auxiliary frequency” function (AUX menu) P P P Continuous display N K = Set Freq. Set Aux # & J A I The programmable function “auxiliary frequency” allows switching to a different strokefrequency, which can...
Page 52 - O p e r a t i n g; emptying only supervised by a competent person.; M a n u a l o p e r a t i o n
Page 52 Pr o Minent ® Dulcodes UV-Desinfektionsanlage O p e r a t i n g 8 O p e r a t i n g This section describes all operating options available to you when the S2Ca is in continuousdisplay mode (no P key symbol in the LCD display). WARNING • For all metering pumps for metering inflammable media a...
Page 53 - O p e r a t i n g / Tro u b l e s h o o t i n g; Settings; R e m o t e c o n t r o l; Tro u b l e s h o o t i n g
Dulcodes UV-Desinfektionsanlage Page 53 Pr o Minent ® O p e r a t i n g / Tro u b l e s h o o t i n g Batch size In “batch” operating mode:The batch size can by changed from the “batch size/remaining litres” display.The S3Ca returns to the original continuous display a few seconds after the batch si...
Page 54 - Error Messages
Page 54 Pr o Minent ® Dulcodes UV-Desinfektionsanlage Tro u b l e s h o o t i n g Green LED indicator (operating display) is not lit Cause Incorrect or no mains voltage. Remedy 왘 Use the recommended mains voltage as given in the voltage specification on thenameplate. Error Messages Red LED display i...
Page 55 - Tro u b l e s h o o t i n g / D e c o m m i s s i o n i n g a n d d i s p o s a l; Fault Signals; D e c o m m i s s i o n i n g a n d d i s p o s a l
Dulcodes UV-Desinfektionsanlage Page 55 Pr o Minent ® Tro u b l e s h o o t i n g / D e c o m m i s s i o n i n g a n d d i s p o s a l Red LED display is lit, “Error” appears in the display and “FAN” is flashing Cause Fault related to fan in pump housing. Remedy 왘 Check fan and replace if necessary...
Page 56 - CAUTION; S p a re p a r t s a n d a c c e s s o r i e s
Page 56 Pr o Minent ® Dulcodes UV-Desinfektionsanlage 1 1 S p a re p a r t s a n d a c c e s s o r i e s CAUTION The assembly and installation of ProMinent ® metering pumps with other-make parts that are not tested and recommended by ProMinent are not permitted and can lead to personalinjury and dam...
Page 57 - M o t o r d a t a s h e e t; ProMinent; Motor Datenblatt / Motor data sheet / Fiche technique pour moteur; ATB
Dulcodes UV-Desinfektionsanlage Page 57 Pr o Minent ® Motor datasheets are available for further information. Special motors and special motor flanges are possible on request. M o t o r d a t a s h e e t Motor-Typ AF 63/4C-7 Leistungsfaktor 0,66 motor type power factor type du moteur facteur de puis...
Page 58 - For pumps without Ex protection:
Page 58 Pr o Minent ® Dulcodes UV-Desinfektionsanlage E C D e c l a r a t i o n o f C o n f o r m i t y For pumps without Ex protection: For pumps with Ex protection: the EC conformity declaration for the pump for explosion-threatened workplaces is supplied with the pump. The EC conformity declarati...
Page 59 - E x p l o d e d d i a g r a m s o f l i q u i d e n d s; * The listed items are constituent parts of the spare part kit.
Dulcodes UV-Desinfektionsanlage Page 59 Pr o Minent ® E x p l o d e d d i a g r a m s o f l i q u i d e n d s Delivery unit Sigma/ 2 350-DN 25 PVT for identity code types: S2Ba/S2Ca 04350, 07120, 07220Delivery unit Sigma/ 2 130-DN 15 PVT for identity code types: S2Ba/S2Ca 12050, 12090, 12130 Spare p...
Page 61 - * The listed items are constituent parts of the spare parts kit.
Dulcodes UV-Desinfektionsanlage Page 61 Pr o Minent ® E x p l o d e d d i a g r a m s o f l i q u i d e n d s Delivery unit Sigma/ 2 350-DN 25 SST for identity code types: S2Ba/S2Ca 04350, 07120, 07220Delivery unit Sigma/ 2 130-DN 15 SST for identity code types: S2Ba/S2Ca 12050, 12090, 12130 Fig. 25...
Page 62 - Retrofit kit double diaphragm S2Ba/S2Ca; * These items belong to the retrofit kit.
Page 62 Pr o Minent ® Dulcodes UV-Desinfektionsanlage E x p l o d e d d i a g r a m s o f l i q u i d e n d s Retrofit kit double diaphragm S2Ba/S2Ca Fig. 26 61_05-104_00_98-03_2 * These items belong to the retrofit kit. Subject to technical modifications. Diaphragm failure detector * Lense Order No...
Page 63 - W i r i n g d i a g r a m; Stroke actuator wiring diagram
Dulcodes UV-Desinfektionsanlage Page 63 Pr o Minent ® W i r i n g d i a g r a m Stroke actuator wiring diagram Wiring diagram for stroke length adjuster N P1 P2 E - Sig. V+ 3 2 1 5 6 7 4 3 2 1 3 2 1 Feedback signal mA Input signal mA PE N L Power supply Power supply