Page 3 - Contents; CONTENTS
Contents 1 About this document........................................................................ 5 1.1 Information on the operating instructions.............................................. 5 1.2 Explanation of symbols..............................................................................
Page 5 - About this document; Information on the operating instructions; Prerequisites for safe work are:; Explanation of symbols
1 About this document 1.1 Information on the operating instructions These operating instructions provide important information on how to use devices fromSICK AG. Prerequisites for safe work are: • Compliance with all safety notes and handling instructions supplied. • Compliance with local work safet...
Page 6 - Further information; SICK Product ID; ABOUT THIS DOCUMENT
1.3 Further information More information can be found on the product page. The page can be accessed via the SICK Product ID : pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product, see type label (if indica...
Page 7 - Safety information; Intended use; Overview; Limitation of liability
2 Safety information 2.1 Intended use The UC40 ultrasonic sensor is used for non-contact detection and distance measure‐ment. Detection and distance measurement below the operating range of the device isnot possible. SICK AG assumes no liability for losses or damage arising from the use of the produ...
Page 8 - Modifications and conversions; NOTICE; Requirements for skilled persons and operating personnel; All work must only ever be carried out by the stipulated persons.; Operational safety and specific hazards
■ Unauthorized conversions or repair ■ Technical modifications ■ Use of unauthorized spare parts, consumables, and accessories 2.5 Modifications and conversions NOTICE Modifications and conversions to the device may result in unforeseeable dangers. Interrupting or modifying the device or SICK softwa...
Page 9 - SAFETY INFORMATION
WARNINGElectrical voltage! Electrical voltage can cause severe injury or death. ■ Work on electrical systems must only be performed by qualified electricians. ■ The power supply must be disconnected when attaching and detaching electricalconnections. ■ The product must only be connected to a voltage...
Page 10 - Product description; Scope of delivery; Further topics; Type code; Type code structure; PRODUCT DESCRIPTION
3 Product description 3.1 Scope of delivery Scope of delivery No. ofunits Component Note 1 Device in the version ordered - 1 Terminal bracket - 1 Printed safety notes, multilingual Brief information and general safety notes Further topics • Accessories The actual scope of delivery may differ for spe...
Page 11 - Device view
3.3 Device view Device view 1 1 2 3 4 4 4 4 5 Figure 1: Device view, example UC40-11211x 1 2 teach-in buttons 2 Release button 3 Male connector, M12, 5-pin 4 4 status LEDs 5 Ultrasonic transducer Further topics • Dimensioned drawing PRODUCT DESCRIPTION 3 8027772/1L5K/2023-09-11 | SICK O P E R A T I ...
Page 12 - Transport and storage; Transport; NOTE; Storage
4 Transport and storage 4.1 Transport NOTICEDamage due to improper transport! ■ The product must be packaged with protection against shock and damp. ■ Recommendation: Use the original packaging. ■ Note the symbols on the packaging. ■ Do not remove packaging until immediately before you start mountin...
Page 13 - Mounting; Mounting instructions; Observe the technical data.; Arranging multiple devices; Teaching in several synchronized devices; MOUNTING
5 Mounting 5.1 Mounting instructions • Observe the technical data. • To prevent condensation, avoid exposing the device to rapid changes in tempera‐ture. • The mounting site has to be designed for the weight of the device. 5.2 Arranging multiple devices 5.2.1 Mounting distances Overview To use multi...
Page 14 - Alignment of the device; Aligning device with alignment aid
5.3 Alignment of the device ≤ ± 3° ≥ ± 3° 1 2 Figure 2: Aligning the device for smooth and rough surfaces 1 Smooth surface: Angle ≤ 90° ± 3° between the sensor axis and object surface 2 Rough surface: Angle ≥ 90° ± 3° between the sensor axis and object surface 5.4 Aligning device with alignment aid ...
Page 15 - Locking and unlocking release button; Mounting device; Approach
5.5 Locking and unlocking release button Approach 5.6 Mounting device Approach 1. Unlock the device. 2. Remove the device from the clamping bracket with the release button pressed. 3. Swivel or rotate the device. MOUNTING 5 8027772/1L5K/2023-09-11 | SICK O P E R A T I N G I N S T R U C T I O N S | U...
Page 16 - Position the device on the clamping bracket and snap it into place.
4. Position the device on the clamping bracket and snap it into place. *c lic k* 5 MOUNTING 16 O P E R A T I N G I N S T R U C T I O N S | UC40 8027772/1L5K/2023-09-11 | SICK Subject to change without notice
Page 17 - Electrical installation; Wiring instructions; Prerequisites for safe operation of the device; Remedial measures; ELECTRICAL INSTALLATION
6 Electrical installation 6.1 Wiring instructions NOTE Pre-assembled cables can be found on the product page.The call is made via the SICK Product ID : pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to the serial number of the product,...
Page 19 - Pin assignment
Electro- optical signal isolator Electro- optical signal isolator Power Supply SICK Device 1 2 2 4 3 6 5 System Controller = 7 = 8 = 9 Figure 4: Example: Prevention of equipotential bonding currents in the system configuration bythe use of electro-optical signal isolators 1 System controller 2 Elect...
Page 21 - Operation; Display and control elements; Teach-in via pushbuttons; OPERATION
7 Operation 7.1 Display and control elements Overview 6 4 3 2 1 5 1 LED 1 2 LED 2 3 LED 3 4 LED 4 5 T1 pushbutton 6 T2 pushbutton Status LEDs Status LED Color Status 1 Orange Pin 2 output status:Operating mode of analog output: on = object outsideanalog scaling; off = object within analog scalingDig...
Page 25 - Teaching in the scaling limits
4. Press T1 for 1 second. ✓ The switching points are taught in. The device automatically switches to normaloperation mode. 7.3.3.4 Teaching in background (Window Mode ± 8%) Overview When the object is located either below the taught-in background -10 mm (IO-Link: -8%)or above the taught-in backgrou...
Page 33 - Establishing a connection to SOPAS ET
7.6 Establishing a connection to SOPAS ET Overview The SOPAS Engineering Tool (SOPAS ET) software is suitable for parameterization aswell as for service and diagnostics purposes. Prerequisites • Product type with IO-Link • A computer with the SOPAS ET software installed on it, and a free USB 2.0comp...
Page 34 - Maintenance; Maintenance plan; Cleaning; Improper cleaning may result in equipment damage.; MAINTENANCE
8 Maintenance 8.1 Maintenance plan During operation, the device works maintenance-free. Table 4: Maintenance plan Maintenance work Interval To be carried outby Check device and connecting cablesfor damage at regular intervals. Depends on ambient conditions andclimate. Specialist Check the screw conn...
Page 35 - Troubleshooting; Repairs; Only send in devices after consulting with SICK Service.; Disposal; The surface of the device can become hot.; TROUBLESHOOTING
9 Troubleshooting 9.1 Repairs Repair work on the device may only be performed by qualified and authorized personnelfrom SICK AG. Interruptions or modifications to the device by the customer will invalid‐ate any warranty claims against SICK AG. 9.2 Returns ► Only send in devices after consulting with...
Page 36 - Technical data; Mechanics/Electronics; TECHNICAL DATA
10 Technical data NOTE The relevant online product page for your product, including technical data, dimensionaldrawing, and connection diagrams, can be downloaded, saved, and printed from theInternet.The page can be accessed via the SICK Product ID : pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the...
Page 39 - Performance; Interfaces
10.3 Performance Operating range UC40-11 2 11x: 65 mm ... 350 mm UC40-11 3 11x: 200 mm ... 1,300 mm UC40-11 4 11x: 350 mm ... 3,400 mm Limiting range UC40-11 2 11x: 600 mm UC40-11 3 11x: 2,000 mm UC40-11 4 11x: 5,000 mm Measuring object Natural objects Resolution UC40-11 2 11x: ≥ 0.1 mm UC40-11 3 11...
Page 40 - Ambient data; Temperature compensation; The device is in a cold state.
Combined: digital oranalog output 2) UC40-11x11 B : not available UC12-11x11 H : number: 1 Digital output • Type: Push-pull: PNP/NPN 1) • Maximum output current I A : ≤ 100 mA Analog output 3) • 4 mA ... 20 mA: RL ≤ 500 Ω 4) • 0 V ... 10 V: RL ≥ 100 kΩ Hysteresis UC40-11211x: 5 mmUC40-11311x: 20...
Page 41 - Detection ranges
10.7 Detection ranges UC40-11211x 200 (7.87) 300 (11.81) 300 (11.81) 200 (7.87) 100 (3.94) 100 (3.94) 0 Detection area in mm (inch) 1 4 5 6 3 0 100 (3.94) 300 (11.81) 200 (7.87) 400 (15.75) 500 (19.69) 600 (23.62) 700 (27.56) Detection area in mm (inch) 1 2 1 Detection range in mm (inch) 2 Detection...
Page 44 - Accessories; ACCESSORIES
11 Accessories NOTE On the product page you will find accessories and, if applicable, related installationinformation for your product.The page can be accessed via the SICK Product ID : pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} corresponds to...
Page 45 - Annex; Declarations of conformity and certificates; The page can be accessed via the; Licenses; More details can be found in the GNU General Public License.; ANNEX
12 Annex 12.1 Declarations of conformity and certificates You can download declarations of conformity and certificates via the product page. The page can be accessed via the SICK Product ID : pid.sick.com/{P/N}/{S/N} {P/N} corresponds to the part number of the product, see type label. {S/N} correspo...