Cartridge installation
1.Carefully remove the stylus from the cartridge
.
2.Connect the wires from the headshell to the pins
on the cartridge
. Use the following table for the
correct connections. Note: To prevent “ground loops”
and hum, do not make common (ground) connec-
tions at these terminals.
R
RED
(RIGHT “HOT”)
RG
GREEN
(RIGHT GROUND)
L
WHITE
(LEFT “HOT”)
LG
BLUE
(LEFT GROUND)
3. Mount cartridge in the headshell and replace stylus
(
and
). Do not force.
note
: screws can be
threaded up from the bottom to provide maximum
record clearance.
4. When the Dynamic Stabilizer brush is set to the op-
erating position
A, it absorbs 0.5 grams of tonearm
tracking force. The proper tonearm settings for the
recommended range of stylus tip tracking forces are:
TRACKING FORCE (in grams)
RECOMMENDED
TRACKING FORCE
RANGE (effective at
stylus tip)
TONEARM SETTING
Dynamic Stabilizer
Down (operating)
A
Dynamic Stabilizer
Up (non-operating)
B
Maximum 1.5 g
optimum
1.25 g
Minimum 0,75 g
2.0 g
1.75 g
1.25 g
1.5 g
1.25 g
0.75 g
5. Make the following final adjustments. Consult your
turntable instructions.
Cartridge overhang
: If adjustable.
anti-skate
: If this adjustment is not speci
-
fied in your turntable instructions, use the
same setting as for tracking force.
tonearm Height
: If adjustable.
dYnaMiC staBiliZer/de-statiCiZer
guard
A
B
The M97xE’s exclusive viscous-damped Dynamic Sta-
bilizer
maintains a uniform distance between the car-
tridge and the record under difficult playing conditions,
such as those caused by warped records or mismatched
tonearm mass. When such stabilization is not required,
the stabilizer can be locked into its up position, which can
improve sound quality under ideal playing conditions.
Over 10,000 conductive fibers in the stabilizer brush
neutralize static charges on the record surface and con-
duct them to the ground. Additionally, the fibers sweep
the record groove clean of dust and dirt in front of the
stylus tip. The Stabilizer also absorbs impact to pre-
vent record or stylus damage if the arm is accidentally
dropped on a record.
side gUard stYlUs ProteCtion sYsteM
The Side-Guard stylus protection system helps prevent
stylus damage if the cartridge accidentally slides across
a record. This system responds to side thrusts on the
stylus by withdrawing the entire stylus cantilever and tip
safely into the stylus housing before the cantilever can
be damaged.
MonoPHoniC PlaYBaCK
For monophonic playback of recordings, the left and right channels should be connected in parallel. This is ac-
complished most conveniently by setting the function switch on the associated preamplifier to “A + B” or “MONO.” If
the existing equipment has a single monophonic input, the two channels of the cartridge should be paralleled and
connected to this single input.
1. Make certain cartridge is correctly mounted in tone-
arm and stylus is properly inserted in cartridge.
2. Protect stylus with stylus guard when dusting turntable.
3. Regulate tonearm set-down to prevent stylus from
striking edge of turntable or record.
4. Do not handle tonearm while record is being played.
Use cueing device if available.
5. If manual set-down is necessary, release arm as
soon as stylus engages groove.
6. Do not activate arm without record(s) on turntable.
7. Do not use damaged records.
8. Check tracking force and anti-skate adjustments pe
-
riodically. The Shure SFG-2 Tracking Force Gauge,
available through your Shure dealer, provides a sim-
ple way to accurately set tracking force.
stYlUs Cleaning
Use the supplied brush to clean the stylus and dynamic
stabilizer. Brush only from back to front, as shown
. Do
not use liquids on the stabilizer brush. Use alcohol or an
alcohol-distilled water solution to clean the stylus. Com-
mercial cleaning solutions may damage the stylus.
©2008, Shure Incorporated
27C3013 (Rev. 4)
Model M97xE User Guide
Printed in U.S.A.
4
5
1
2
3
Cartridge oPeration
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
ProdUCt sPeCiFiCations Replacement Stylus Stabilizer Color Stereo Output (1 kHz at 5 cm/sec peack recorded velocity) Frequency Response Trackability at 1.25 g Tracking Force (cm/sec Peak Velocity) N97xE Blue 4.0 mV 20 to 22,000 Hz 400 Hz – 30 cm/sec 1 kHz – 44 cm/sec 10 kHz – 31 cm/sec Features Very...
einBaU des tonaBneHMers 1. Die Abtastnadel vorsichtig aus dem Tonabnehmer entfernen . 2. Die Drähte des Tonarmkopfs an die Stifte des Tonabnehmers anschließen . Die richtigen Anschlüsse sind der folgenden Tabelle zu entnehmen. Hinweis: Zur Verhinderung von Erdschleifen und Brummen die gemeinsame...
カートリッジの取付け 1. 針をカートリッジから、注意しながら取り外します(ー ー照)。 2. ヘッドシェルのワイヤをカートリッジのピンに接ーします(ー ー 照)。下記の表にーいー正確に接ーしてください。注記: ーアースのルー プー やハムを避けるため、これらのターミナルには共通(アース)は 接ーしないでください。 R 赤 (右ーホットー) RG ー (右アース) L 白 (左ーホットー) LG ー (左アース) 3. ヘッドシェルにカートリッジを取り付けー針を取り付けます(ーおよ びー ー照)。無理な力をかけないでください。注記: ネジを下側か らつけるとー最大限のレコードークリアランスが確...