Table of Contents:

  • Page 2 – SPECIAL PRECAUTIONS; accidental injury or death.; N O T E; CAUTION
  • Page 3 – Check of Density Limit; Min. volume of the indoor unit installed room (m; If there are 2 or more refrigerating systems in a sin-
  • Page 4 – -3. Type of Copper Tube and Insulation Material; CONTENTS
  • Page 6 – HOW TO INSTALL THE UNIT; Under ceiling installation.
  • Page 8 – ELECTRICAL WIRING
  • Page 9 – and Wire Diameter for Power Supply System” for; P terminal board
  • Page 10 – branch wiring. Star branch wiring causes mis-address
  • Page 11 – wise misoperation from noise may occur.; How to connect wiring to the terminal
  • Page 12 – HOW TO PROCESS TUBING; Use of the Flaring Method; Deburring
  • Page 13 – Tube diameter
  • Page 14 – * For gas tubing, the insulation material must be; Packed valve
  • Page 16 – Installing the Control Unit
  • Page 17 – Care and Cleaning; How to remove the filter; Grasp both ends of the air intake grille and pull to open it.; FILTER CLEANING
  • Page 18 – Trouble Possible; Avoid; NOTE
  • Page 19 – Entretien et nettoyage; Ne versez pas d’eau sur l’unité intérieure pour la nettoyer. Cela; au moins une fois tous les deux semaines; ATTENTION; Comment retirer le filtre; Quand on remet le filtre en place, vérifier que le repère FRONT; NETTOYAGE DU FILTRE
  • Page 20 – Panne; Choses à faire; REMARQUE
  • Page 21 – Pflege und Reinigung; auszuschalten und es außerdem vom Netz zu trennen.; werden; WARNUNG; VORSICHT; Den Filter an der Lasche nehmen und nach oben herausziehen.; Herausnehmen des; FILTERREINIGUNG
  • Page 22 – Fehlersuche; Störung; Zu vermeiden; ZUR BEACHTUNG
  • Page 23 – Cura e manutenzione; Non versare acqua sull’unità interna per pulirla. Ciò può; PRECAUZIONE; Aprire il pannello griglia di aspirazione tirandolo verso di voi.; PULIZIA FILTRO
  • Page 24 – Prima di chiamare il tecnico; Problema; Da evitare; NOTA
  • Page 25 – Cuidados e limpeza; de filtro ( ) aparece no visor da unidade; PRECAUÇÃO; Como remover o filtro; LIMPEZA DO FILTRO
  • Page 26 – Avaria; Evite
  • Page 27 – Πώς; FT
  • Page 28 – OFF; ΠΑΡΑΤΗΡΗΣΗ
  • Page 29 – Cuidados y limpieza; Por motivos de seguridad, asegúrese de apagar el acondicionador; indicación de filtro ( ) del visualizador de la unidad del mando a; PRECAUCIÓN; Abrir la puerta de la rejilla de aspiración tirando hacia sí.; Cómo extraer el filtro; LIMPIEZA DEL FILTRO
  • Page 30 – Avería
Loading the manual

– DC INVERTER Air Conditioner –

INSTALLATION AND OPERATION MANUAL

R410A Models
Indoor Units

Outdoor Units

SPW-FTR124EH56
SPW-FTR164EH56
SPW-FTR184EH56

* Refrigerant R410A is used in the outdoor units.

C

DC Inverter Main Unit

SPW-CR254GVH56-C, SPW-CR364GVH56-C, SPW-CR484GVH56-C

Constant Speed (Sub) Unit

SPW-CR254GV56-C, SPW-CR364GV56-C, SPW-CR484GV56-C

Optional Controllers

Remote Controller

RCS-SH80AG

Wireless Remote Controller

RCS-TH80AG.WL

RC

Wireless Remote Controller

RCS-BH80AG.WL

Simplified Remote Controller

RCS-KR1AG

for Refrigerant R410A

SANYO Airconditioners Europe S.r.l.

Via Bisceglie, No. 76

20152 Milano, Italy

37.4196.062.0 ©SANYO 2005

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - SPECIAL PRECAUTIONS; accidental injury or death.; N O T E; CAUTION

2 IMPORTANT! Please Read Before Starting This air conditioning system meets strict safety and operat-ing standards. As the installer or service person, it is animportant part of your job to install or service the system so itoperates safely and efficiently. For safe installation and trouble-free ope...

Page 3 - Check of Density Limit; Min. volume of the indoor unit installed room (m; If there are 2 or more refrigerating systems in a sin-

3 2. The standards for minimum room volume are as follows. (1) No partition (shaded portion) (2) When there is an effective opening with the adja- cent room for ventilation of leaking refrigerant gas(opening without a door, or an opening 0.15% orlarger than the respective floor spaces at the topor b...

Page 4 - -3. Type of Copper Tube and Insulation Material; CONTENTS

BOLT M8 4 1. GENERAL This booklet briefly outlines where and how to install the air conditioning system. Please read over the entire set of instructions for the indoor unit and make sure all accessory parts listed are with the system before beginning. 1-3. Type of Copper Tube and Insulation Material...

Other Sanyo Models