Table of Contents:

  • Page 2 – How to wire the remote controller; wires are used for lead wires.; Peel off 14mm of cable; Wall
  • Page 3 – FAN MOTOR; FLP; CONTROLLER; • Electric Wiring Diagram; T e r m i n a l p l a t e; * G R E E N M A R K o n; G r i l l e a i r o u t l e t; I n d o o r E l e c t r i c a l C o m p o n e n t B o x
  • Page 4 – INDOOR UNIT; How to test run the air conditioner; Press the ON/OFF button on the remote control unit; N O T E
Loading the manual

Parts supplied with remote controller

See Table 1.

Remote controller installation guidelines

• Mount the remote controller 1 to 1.5 meters off the

floor where it can sense the average temperature of
the room.

• Do not mount the remote controller in a place

exposed to direct sunlight or where it is exposed to
outside air such as near a window.

• Do not mount the remote controller behind a curtain

or other object so that it is separated from the air cir-
culation of the room.

• Mount the remote controller inside the room being air

conditioned.

• The remote controller should be mounted on a wall or

other surface vertically.

Room temperature sensors are separately incorporated
in both the indoor unit and the remote controller. Either
sensor can be used to sense the room temperature. The
indoor unit sensor is usually used.
If you wish the remote controller to sense the room tem-
perature, press the SENSOR button with a ballpoint pen
or tool with a small tip.

How to install the remote controller

<NOTE 1>

Do not twist the remote controller wire
with the power cord, or run them in the
same metal conduit, because this may
cause a malfunction.

<NOTE 2>

Install the remote controller away from all
sources of electrical noise.

<NOTE 3>

Install a noise filter or take other appro-
priate action if electrical noise affects the
power supply circuit of the unit.

• Use an electric junction box (supplied locally) for

embedded mounting of the remote controller.
(See Fig. 1)

Switching the room temperature sensor

Installation location

Q’ty

No.

1

Supplied parts

Remote
controller

(comes with
200mm wire)

Machine screws
M4

×

25

Tapping screws
M4

×

25

2

2

Q’ty

No.

2

Supplied parts

Spacers

Wire joints

Harness

Clamper

Instruction manual

6

1

1

1

Table 1

85464359404000 © SANYO 2003

Note: Remote controller model name RCS-KS2432AWD

Code: 851-0-0054-590-00-0

W

INSTALLATION INSTRUCTIONS

Fig. 1

Wall

Under-case (back case)

Electric junction box
(no cover)

Spacers

Remote controller

Lead wires (3)

Machine screws
M4

×

25 (2)

RCS-KS2432AWD

03-242.Sanyo.85464359404000 8/21/03 9:17 AM Page 1

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - How to wire the remote controller; wires are used for lead wires.; Peel off 14mm of cable; Wall

2 • For surface mounting on the wall, see Fig. 2. 1. Insert a screwdriver or the like in the groove on the lower side of the remote controller to pry off theback case. (See Fig. 3) 2. Use the 2 supplied M4 × 25 machine screws for embeded mounting or M4 × 25 tapping screws for surface mounting to sec...

Page 3 - FAN MOTOR; FLP; CONTROLLER; • Electric Wiring Diagram; T e r m i n a l p l a t e; * G R E E N M A R K o n; G r i l l e a i r o u t l e t; I n d o o r E l e c t r i c a l C o m p o n e n t B o x

3 Fig. 5 8 7 6 5 4 3 2 18 7 6 5 4 3 2 1 12345 12345 12345 12345 FLP CONNECTOR FLAP25P [BLK] FLAP15P [WHT] LAMP 4P [WHT] RECEIVER 3P [WHT] SEC2P [WHT] PRY3P [RED] SUP5P [WHT] ROOM/COIL4P [WHT] [WHT] [GRN] [BLK] WHT BLUBLUBLUBLU 12 12 13 13 321 321 1234 1234 1234567 1234567 1234 1234 1 3 51 3 5 FR OM ...

Page 4 - INDOOR UNIT; How to test run the air conditioner; Press the ON/OFF button on the remote control unit; N O T E

4 Fig. 7 OPERATION TIMER ONOFFTEST INDOOR UNIT OPERATION lamp Operation selector Remote controlreceiver TIMER lamp ■ How to test run the air conditioner 1. Switch on the power source. 2. Press the ON/OFF button on the remote control unit once. 3. Set the operation selector switch of the indoor unit ...