Specifications

CD010830

Discharge

Storage

Ambient
Temperature

Nominal Capacity

Nominal Voltage

Charging Current

Charging Time

Charge

Internal Impedance (Av.)

Dimensions(D)

×××××

(H)

Weight

g/

(at 1000Hz)

×××××
×××××

m m

inch

1200mAh

1.2V

120mA

240mA

14 to 16Hrs.

7 to 8Hrs.

°C to

0

+45

+32

113

°C [

°F to

°F ]

°C to +50

-22

122

°C [

°F to

°F ]

°C to +45

+32

113

°C [

°F to

°F ]

°C to +60

-4

140

°C [

°F to

°F ]

0

-20

-30

9.7

3 7

1.31

22.9

0.90

34.0

1.34

0
-1

0
-1.2

0
-0.04

0
-0.05

m

oz

(at. 50% discharge)

(with tube)

Typical Characteristics

Standard

Quick

Standard

Quick

Standard

Quick

Dimensions

o f

Bare Cell

H

D

d

m m

m m

m m

inch

inch

inch

33.0

0.3

1.299

0.012

22.0

0.866

10.0

0.394

0.3

0.012

C h a r g e

Discharge

(at high rate)

Discharge

(at high rate)

C h a r g e

Discharge

(at low rate)

Temperature

(Charge & Discharge)

Cell Type KR-1200SCL

±

±

±

±

1.2

1.3

1.4

1.5

1.6

0

2

4

6

8

10

12

14

16

0°C/32°F

20°C/68°F

Cell Voltage (V)

Charge Time (Hrs.)

Charge :120mA

45°C/113°F

1.2

1.3

1.4

1.5

1.6

0

20

40

60

80

100

120

140

160

0.2 It

0.1 It

Cell Voltage (V)

Charge Input ( % )

Temperature : 20°C/68°F

0.6

0.8

1.0

1.2

1.4

0

2

4

6

8

10

12

14

16

(0.5 It)

(0.2 It)

(0.1 It)

Cell Voltage (V)

Discharge Time (Hrs.)

Charge : 120mA

×

16Hrs.

at 20°C/68°F

30

40

50

60

70

80

90

100

110

Available Capacity (%)

Operating Temperature

Condition

Charge : 120mA

×

16Hrs.

Discharge : 240mA
(End Volt 1.0V)

{

Charge Characteristics
Discharge Characteristics

50

122

40

104

30
86

20
68

10
50

0

32

60°C

140°F

-10

14

-20

-4

0.6

0.8

1.0

1.2

1.4

0

2

4

6

8

10

12

14

16

Cell Voltage (V)

Discharge Time (Mins)

(8 It)

(4 It)

at 20°C/68°F

Charge : 120mA

×

16Hrs.

0.6

0.8

1.0

1.2

1.4

0

10

20

30

40

50

60

70

80

(2 It)

(1 It)

Cell Voltage (V)

Discharge Time (Mins)

at 20°C/68°F

Charge : 120mA

×

16Hrs.

D

d

H