Sanyo HR-3URS - Manual
Sanyo HR-3URS – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Size : AA Consumer Type
2300mAh
2100mAh
1.2V
Quick Charge
2)
CV=1.64V x app.15min.
Max.Current=10A
Charge
2)
CV=1.70V x app.70min.
Max.Current=2.3A
Ambient Temp.
Charge
Condition
Quick Charge
2)
10°C - 40°C
Charge
2)
0°C - 40°C
0°C - 50°C
Less than 30days
-20°C - 50°C
Less than 90days
-20°C - 40°C
D
Less than 1year
-20°C - 30°C
H
Approx. 25m
Ω
(at 1000Hz)
Approx. 30 g
14.35(D) x 50.4(H) mm
Typical Characteristics
Charge
Discharge
Dimensions
(with tube)
50.4 mm
Specifications
Cell Type HR-3URS
Type : Nickel-Metal Hydride Battery
14.35 mm
50.4 mm
14.35 mm
Capacity
1)
Typical
2)Use recommended charging system.
3)After a few charge and discharge cycles under the above 1) condition
4)With tube.
1)Single cell capacity under the following condition.
Charge : CC;230mA+CV;CV=1.75V, Total Timer;16h, Discharge : 460mA(E.V.=1.0V)
Weight
4)
Size
4)
:(Diameter) x (Height)
Constant Charging Voltage
Maximum Charging Current
x Time
Minimum
Nominal Voltage
Discharge Condition
Internal Impedance
3)
(after discharge to E.V.=1.0V)
Storage
Condition
0.9
1.0
1.1
1.2
1.3
1.4
1.5
1.6
0
500
1000
1500
2000
2500
Discharge Capacity (mAh)
C
e
ll Voltage (V)
Charge : 1.64V/10A x 16min
Rest : 1h
Discharge : 460mA, 1150mA, 2300mA, 4600mA
(E.V.=1.0V)
Ambient Temp. : 20°C
460mA
2300mA
1150mA
4600mA
1.2
1.3
1.4
1.5
1.6
1.7
1.8
0
2
4
6
8
10
12
14
16
18
Charge Time (min.)
Cell V
olt
age (
V
)
0
4
8
12
16
20
24
C
urre
nt
(A)
Charge : 1.64V/10A x 16min
Ambient Temp. : 10°C,25°C,40°C
10°
40°
25°
25°
40°