Sanyo CP-1700SCR - Manual

Sanyo CP-1700SCR

Sanyo CP-1700SCR – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

Standard

Fast

Standard

Fast

Standard

Fast

Discharge

Storage

Ambient
Temperature

Nominal Capacity

Nominal Voltage

Charging Current

Charging Time

Charge

Internal Impedance (Av.)
(at. 50% discharge)

Dimensions(D)

×××××

(H)

(with tube)

Weight

g/

(at 1000Hz)

×××××
×××××

mm

inch

Typical Characteristics

Charge

Cell Type CP-1700SCR

Specifications

Dimensions

of

Bare Cell

H

D

d

mm

mm

mm

inch

inch

inch

Discharge

(at high rate)

Cell capacity

(at various discharge rate)

Discharge

(at high rate)

Discharge

(at low rate)

Temperature

(Charge & Discharge)

33.0

0.3

1.299

0.012

22.0

0.866

10

0.394

0.3

0.012

1700mAh

1.2V

170mA

2550mA

°C to

0

+45

+32

113

°C

[

°F to

°F

]

°C to +50

-22

122

°C

[

°F to

°F

]

°C to +40

+41

104

°C

[

°F to

°F

]

°C to +60

-4

140

°C

[

°F to

°F

]

5

-20

-30

5.5

46 1.62

22.9

0.90

34.0

1.34

0

-1

0

-1.2

0

-0.04

0

-0.05

m

oz

±

±

±

±

14 to 16Hrs.

about 1Hr.

1.2

1.3

1.4

1.5

1.6

1.7

0

10

20

30

40

50

5°C/41°F

20°C/68°F

Cell Voltage (V)

Charge Time (Mins)

40°C/104°F

Charge : 2.55 A

V=10mV

30

40

50

60

70

80

90

100

110

-20

-10

0

10

20

30

40

50

60

Available Capacity (%)

Operating Temperature

Condition

Charge : 2.55A

V=10mV

Discharge : 340mA
(End Volt 1.0V)

{

140

122

104

86

68

50

32

14

-4

°F

°C

Charge Characteristics
Discharge Characteristics

0.6

0.8

1.0

1.2

1.4

0

2

4

6

8

10

12

14

16

Cell Voltage (V)

Discharge Time (Mins)

(8 It)

(4 It)

Charge : 2.55 A

V=10mV

at 20°C/68°F

0.6

0.8

1.0

1.2

1.4

0

10

20

30

40

50

60

70

80

(2 It)

(1 It)

Cell Voltage (V)

Discharge Time (Mins)

Charge : 2.55 A

V=10mV

at 20°C/68°F

0.6

0.8

1.0

1.2

1.4

0

2

4

6

8

10

12

14

16

(0.5 It)

(0.2 It)

(0.1 It)

Cell Voltage (V)

Discharge Time (Hrs.)

Charge : 2.55A

V=10mV

at 20°C/68°F

40

50

60

70

80

90

100

110

0

1

2

3

4

5

6

7

8

Available Capacity ( % )

Discharge Rate (It)

Charge : 2.55A

V=10mV

Discharge : End Volt 1.0V

at 20°C/68°F

CD010830

D

d

H

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.