Sanyo 09KS51 - Manual
Sanyo 09KS51 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
SUBMITTAL SHEET
SYSTEM
INDOOR/OUTDOOR
09KS51
KS0951/C0951
WALL MOUNT AIR CONDITIONER
GENERAL DATA (AT 115V)
POWER V/PH/HZ
115/1/60
Circuit Ampacity, Min. (A)
15
Fuse size, Max.
(A)
15
COMPRESSOR
Rotary-Hermetic
No. used
1
R.L. Amps - L.R. Amps (A)
7.7-49
Crankcase Heater
OUTDOOR FAN - TYPE
Propeller
Dia. (in.) - No. used
16-17/32 - 1
Type Drive - No. speeds
Direct - 1
No. Poles - RPM (High)
6 - 600
No. Motors - W
1 - 21.6
CFM (High)
1020
F.L. Amps. (A)
0.7
OUTDOOR COIL - TYPE
Aluminum Fin & Copper Pipe
Fin Type - Pipe Type
Slit Plate - Inner Flat
Rows - F.P.I.
1 - 18
Face Area (sq.ft.)
4.2
Tube Size (in.)
3/8
INDOOR FAN - TYPE
Cross-flow
Dia. & Length (in.) - No. used
3-3/4 & 24-9/32-1
No. speeds
3 & Auto
No. Poles -RPM (High)
4-1,200
No. Motors - W
1 - 18.2
CFM (HI/MED/LOW)
270/240/220
F.L. Amps (A)
0.4
INDOOR COIL - TYPE
Alminum Fin & Copper Pipe
Fin Type - Pipe type
Slit Plate - Inner Flat
Rows - F.P.I.
2 - 18
Face Area (sq. ft.)
1.4
Tube Size (mm)
7
Drain Connection Size (in.)
23/32
REFRIGERANT
R22
Lbs. - R22 (O.D. Unit)
1.28
Control
Capillary Tube
Connection
Flare
Line Length, Max (ft.)
50
Lift difference, Max (ft.)
23
Line Size - in. O.D. Discharge 1/4
Line Size - in. O.D. Suction
3/8
DIMENSIONS (in.)
H
x
W
x
D
Indoor Unit
-Uncrated 10-5/8
x 31-11/16 x 6-31/32
-Crated
9-13/16 x 33-21/32 x 13-5/16
Outdoor Unit -Uncrated 21-1/4
x 31-1/2
x 11-13/32
-Crated
23-31/32 x 38-5/8
x 16-3/16
WEIGHT
INDOOR OUTDOOR
Net
(lbs.)
17.6
66.1
Shipping (lbs.)
22.0
75.0
Shipping Volume (cu.ft.)
2.51
8.67
SS09KS51-2
PERFORMANCE DATA @ ARI STANDARD CONDITIONS
(115V)
COOLING
Total Capacity
(BTU/H)
9,000
Sensible Capacity (BTU/H)
6,420
Latent Capacity
(BTU/H)
2,580
SEER
10.0
Dehumidification
(Pints/H)
2.0
Amps
(A)
8.8
Power Inputs
(W)
900
Outdoor Sound Rating (bels)
7.0
FEATURE
Controls
Microprocessor
Remote Controller
LCD Wireless type
Temperature Control
IC Thermostat
Timer
ON/OFF, ProgramTimer
Night Setback
Built-In
Air Louver
(Horizontal)
Manual
(Vertical)
Auto
Power Failure Automatic Restart
Built-In
Self Diagnosis
N/A
OPTION
Refrigerant Line Set
AP0905BH (15 ft)
AP0907BH (20 ft)
AP0910BH (30 ft)
Air Clean-Filter
STK-ARF4B
Fresh Air Intake
N/A
Central Remote ON-OFF Control
Available
Airduct Extension
N/A
Indoor Frame Extension
N/A
Condensate Drain Pump
Optional
Non-Removable Remo-con Bracket
Optional
OPERATING RANGE
Cooling
Indoor Air
Outdoor Air
Intake Temp.
Intake Temp.
Maximum 95 F DB/71 F WB
115 F DB
Minimum
67 F DB/57 F WB
67 F DB
CERTIFICATION
09KS51
AIRCONDITIONING PRODUCTS
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.