Samsung AM500FNBDEH/EU - User Manual

Samsung AM500FNBDEH/EU

Samsung AM500FNBDEH/EU Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
Page: / 74

Table of Contents:

  • Page 2 – Contents; Correct Disposal of This Product; (Applicable in countries with separate collection systems)
  • Page 3 – ENGLISH; Safety precautions; You must connect the outdoor unit for R-410A refrigerant.; WARNING; severe personal injury or death.; CAUTION; Hazards or unsafe practices that may result in; minor personal injury or property damage.
  • Page 4 – SEVERE WARNING SIGNS; Installation must be requested to a qualified installer.
  • Page 5 – CAUTION SIGNS
  • Page 6 – Combination rate
  • Page 7 – Preparing the installation; Tools required for installation; General tools; Recommended specification of the strainer
  • Page 8 – Selecting installation location; Choose a flat place that rainwater does not settle or leak.; Space requirement
  • Page 9 – Hydro unit; Hydro unit HT
  • Page 10 – Base ground construction; DVM Hydro unit installation
  • Page 11 – DVM Hydro unit HT installation
  • Page 13 – Dimension of the Hydro unit HT
  • Page 14 – Refrigerant pipe installation; Refrigerant pipe work; Model name of DVM Hydro unit; Amount of additional refrigerant; Refrigerant type
  • Page 15 – The F-GAS label must be adhered in the proximity of the product.; Tools used for refrigerant pipe installation
  • Page 16 – Selecting refrigerant pipe; Pinching the refrigerant pipe; Seal the end of the refrigerant pipe with a PVC vinyl tape.
  • Page 17 – Refrigerant pipe welding and safety information; Important information for refrigerant pipe work; Make sure there is no moisture inside the pipe.; Nitrogen flushing welding (DVM Hydro unit); Avoid welding the pipe with pipe direction heading upward.
  • Page 18 – Refrigerant pipe work on DVM Hydro unit; Caution for welding the pipe to a DVM Hydro unit; then weld the connecting pipe on each port.
  • Page 19 – Refrigerant pipe work on DVM Hydro unit HT; DVM Hydro unit HT has refrigerant pipes of two different types.; connecting refrigerant pipes to each port of the Hydro unit HT.
  • Page 20 – Performing leak test and insulation; Leak test; Selecting the insulator of refrigerant pipe; Pipe; - Make sure that the opening part of the insulation to face up.
  • Page 21 – Installing the drain pipe; For smooth drainage, install an air vent that is open to air.; Checking the water leakage
  • Page 22 – Water pipe installation; must follow on site installation specification.
  • Page 23 – Installing under floor heating
  • Page 24 – torque, it may cause damage to the product.
  • Page 25 – air conditioning equipment.
  • Page 26 – Pressure drop graphs
  • Page 27 – Connecting strainer; Connecting power and communication cable; Specification of electric wires
  • Page 28 – Example of Installation; Total 10 indoor units were installed
  • Page 29 – Apply following equation; Overall system configuration
  • Page 30 – DVM Hydro unit HT; BDE
  • Page 31 – Power supply and communication cable configuration; Fix a cable tube at the cable outlet using a CD connector.
  • Page 32 – Specifications of the cable protection tube; Name; Power and communication wiring diagram
  • Page 33 – PBA connection diagram; ADN
  • Page 35 – Wiring diagram for connecting 2 wired remote controllers
  • Page 36 – Connecting the power terminal; Terminal name
  • Page 37 – Selecting solderless ring terminal; Nominal dimensions for cable (mm
  • Page 38 – How to connect your extended power cables; Tools; Spec; Push the core wire into the sleeve from both sides.; Twist the wire cores together and push it into the sleeve.; Method 1
  • Page 39 – Apply heat to the contraction tube to contract it.; - Incomplete wire connections can cause electric shock or a fire.
  • Page 40 – Connecting external contact; External contact connection diagram
  • Page 41 – Explanation
  • Page 42 – External contact
  • Page 43 – Water pump connection; Connect a water pump to B5, B6 of the PBA terminal block.; Specification table; Part
  • Page 44 – Booster heater connection; Connect a booster heater to B7, B8 of the PBA terminal block.
  • Page 45 – Way valve connection; Use a rated wire and connect it as shown in the illustration.; Allowed connection; AB
  • Page 46 – -port diverter valves
  • Page 47 – Connect B1
  • Page 48 – Connecting 2Way valve; Connect a 2Way valve to B15, B16 and B17 of the PBA terminal block.
  • Page 49 – Wiring 2Way valve
  • Page 50 – Connect the indoor thermostat to B19~B26 of the PBA terminal block.; Maximum allowable current of each terminal is below 10mA; Condition for operation
  • Page 51 – Cooling mode
  • Page 52 – Connecting temperature sensor of water tank and flow switch
  • Page 53 – Connecting solar pump; Maximum allowable current of each terminal is below 10 mA.
  • Page 54 – Grounding work; Select a appropriate place to install a ground rod.
  • Page 55 – Setting an indoor unit address and installation option; The procedure of option setting; Step 1. Entering mode to set option; Remove batteries from the remote controller.; Step 2. The procedure of option setting; Option setting is available from SEG1 to SEG 24
  • Page 56 – Option setting
  • Page 57 – Step 3. Check the option you have set
  • Page 58 – Check whether power is supplied or not.
  • Page 59 – 2 series installation option
  • Page 60 – Use of external control function in SEG 14
  • Page 61 – 5 series installation option
  • Page 62 – Changing a particular option; You can change each digit of set option.; Ex) When setting the ‘buzzer control’ into disuse status.
  • Page 63 – Product maintenance; Water quality management
  • Page 64 – Failure diagnosis; Display on the remote controller display when error is detected; Error indications are displayed as seen below.; Outdoor unit error
  • Page 65 – Error code; Please follow below instruction when there is error on sensor.; Display
  • Page 66 – System diagram for DVM Hydro unit / Hydro unit HT
  • Page 67 – Using the PCB Switch; Switch is located on the control kit PCB; Displayed contents
  • Page 68 – Switch is located on the Main PCB (AM; TACT S/W specification setting
  • Page 69 – temperature
  • Page 70 – Tact
  • Page 71 – Setting key function (AM; the function for the selected option.; Operation item
  • Page 72 – Completing the installation; The measured value should be over 30 MΩ; Explaining functions to the user; the outside temperature is under the 0 °C
  • Page 73 – Appendix; Model specification (weight and dimension); Type
  • Page 74 – This product is India RoHS compliant
Loading the manual

Air conditioner

Installation manual

ADN***BDE** / AM***FNBD** / AM***FNBF** / AM***TNBF**

Thank you for purchasing this Samsung Product.

Before operating this unit, please read this manual carefully and retain it for future reference.

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Samsung AM500FNBDEH/EU

Summary

Page 2 - Contents; Correct Disposal of This Product; (Applicable in countries with separate collection systems)

2 Contents Safety precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3Preparing the installation . . . . . . . . . . . . . . . . . . ...

Page 3 - ENGLISH; Safety precautions; You must connect the outdoor unit for R-410A refrigerant.; WARNING; severe personal injury or death.; CAUTION; Hazards or unsafe practices that may result in; minor personal injury or property damage.

3 ENGLISH Safety precautions Before installing an DVM Hydro unit / Hydro unit HT please read this manual thoroughly to ensure that you know how to safely and efficiently install a new appliance.Store the Operation and Installation in a safe location and remember to hand it over to the new owner if t...

Page 4 - SEVERE WARNING SIGNS; Installation must be requested to a qualified installer.

4 Safety precautions SEVERE WARNING SIGNS Installation must be requested to a qualified installer. f If the user installs a product improperly on their own, it may cause refrigerant leakage and lead to electric shock or fire in worst case scenario. Install the unit in a place where it is strong enou...

Other Samsung Air Conditioners Models