Samsung AM040BXMDEH/EU - User Manual

Samsung AM040BXMDEH/EU

Samsung AM040BXMDEH/EU Air Conditioner – User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
2 Page 2
3 Page 3
4 Page 4
5 Page 5
6 Page 6
7 Page 7
8 Page 8
9 Page 9
10 Page 10
11 Page 11
12 Page 12
13 Page 13
14 Page 14
15 Page 15
16 Page 16
17 Page 17
18 Page 18
19 Page 19
20 Page 20
21 Page 21
22 Page 22
23 Page 23
24 Page 24
25 Page 25
26 Page 26
27 Page 27
28 Page 28
29 Page 29
30 Page 30
31 Page 31
32 Page 32
33 Page 33
34 Page 34
35 Page 35
36 Page 36
37 Page 37
38 Page 38
39 Page 39
40 Page 40
41 Page 41
42 Page 42
43 Page 43
44 Page 44
45 Page 45
46 Page 46
47 Page 47
48 Page 48
49 Page 49
50 Page 50
51 Page 51
52 Page 52
53 Page 53
54 Page 54
55 Page 55
56 Page 56
57 Page 57
58 Page 58
59 Page 59
60 Page 60
61 Page 61
62 Page 62
63 Page 63
64 Page 64
65 Page 65
66 Page 66
67 Page 67
68 Page 68
69 Page 69
70 Page 70
71 Page 71
72 Page 72
73 Page 73
74 Page 74
75 Page 75
Page: / 75

Table of Contents:

  • Page 2 – AA; Contents
  • Page 3 – ENGLISH; Safety precautions
  • Page 6 – Preparations for Installation; Outdoor unit classification; Accessories
  • Page 7 – Optional accessories; Selecting installation location
  • Page 8 – Installation Guide at the seashore
  • Page 10 – Space requirements
  • Page 11 – Installation location; Instructions for parallel installation
  • Page 14 – Moving the outdoor unit
  • Page 15 – Base construction and installation; of the outdoor unit; Installation of outdoor unit
  • Page 16 – Base ground contruction
  • Page 18 – Installation of Air-conditioner; Refrigerant pipe work
  • Page 19 – Size of the pipe between branch joints; Selecting refrigerant pipe
  • Page 20 – Selecting additional refrigerant charging; Amount of additional refrigerant for each indoor unit
  • Page 21 – Method to calculate total amount of additional refrigerant
  • Page 22 – Keeping refrigerant pipe
  • Page 23 – Temper grade and minimum thickness of the refrigerant pipe
  • Page 24 – Cutting or flaring the pipes
  • Page 25 – Connecting the flared pipes
  • Page 26 – Pipe installation for an outdoor unit
  • Page 27 – Connecting the drain hose to the outdoor unit
  • Page 28 – Examples of refrigerant pipe installation
  • Page 33 – Installation of refrigerant Y-joint
  • Page 35 – Installation the distribution header
  • Page 36 – DVM S ECO Series; Wiring work; Specification of the circuit breaker and power cable
  • Page 37 – Specification of the protection tube
  • Page 38 – Power wiring Diagram; EEV
  • Page 40 – Selecting solderless ring terminal
  • Page 41 – Connecting the power terminal; Examples of how to use the cable striper
  • Page 42 – Fixing the power cabel; Connect the ring terminal of 3 phase cable
  • Page 43 – Installing grounding wire
  • Page 45 – Air tightness test and Vacuum drying; Air Tightness
  • Page 46 – Vacuum drying pipes and indoor unts
  • Page 47 – Charging refrigerant
  • Page 49 – Insulating the refrigerant pipes and branch joints; Pipe insulation; Selecting the refrigerant pipe insulator
  • Page 50 – Insulate the refrigerant pipe
  • Page 51 – Insulating the branchjoint; Insulate the distribution header
  • Page 52 – Insulating the pipe located inside of the outdoor unit
  • Page 53 – Basic segment display
  • Page 54 – Setting outdoor unit option switch and key function; Setting outdoor unit key function
  • Page 55 – Setting total number of installed indoor units using K1~K4
  • Page 56 – Setting the option
  • Page 60 – Setting key operation and checking the view mode with tact switch
  • Page 67 – Things to check after completing the installation
  • Page 69 – Inspection & trial operation; Checklist before auto trial operation
  • Page 70 – Auto trial operation
  • Page 71 – Measure to take when E503 error occurs
  • Page 72 – Automatic refrigerant amount detection function
  • Page 73 – Model specification (Dimension and weight)
  • Page 75 – imagine; Thank you for purchasing this Samsung product.; Air Conditioner; Installation manual
Loading the manual

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Manuals for Samsung AM040BXMDEH/EU

Summary

Page 2 - AA; Contents

2 AA Contents · Selecting solderless ring terminal .................... 40· Connecting the power terminal ....................... 41· Fixing the power cabel .......................................... 42· Installing grounding wire ..................................... 43 Air tightness test and vacuum...

Page 3 - ENGLISH; Safety precautions

3 ENGLISH WARNING • Hazards or unsafe practices that may result in severe personal injury or death. CAUTION • Hazards or unsafe practices that may result in minor personal injury (to installer/user) or property damage. SEVERE WARNING SIGNS Consult qualified installer or dealer for installation. X X ...

Page 6 - Preparations for Installation; Outdoor unit classification; Accessories

6 AA Preparations for Installation Outdoor unit classification Appearance DVM S ECO AM100/120/140KXMDG  AM030RXMDEH  AM040/050KXMDEH  Safety precautions Changes in DVM S ECO (inverter) compare to conventional models that has to noted when installing X X For optimal distribution of the refrigerant...