Page 2 - Contents; At a Glance; Cleaning and Maintenance
2 English Contents Correct Disposal of This Product (Waste Electrical & Electronic Equipment) (Applicable in countries with separate collection systems) This marking on the product, accessories or literature indicates that the product and its electronic accessories (e.g. charger, headset, USB ca...
Page 3 - mation; WARNING
Safety Infor mation 3 English Before using your new air conditioner, please read this manual thoroughly to ensure that you know how to safely and efficiently operate the extensive features and functions of your new appliance.Because the following operating instructions cover various models, the char...
Page 4 - FOR INSTALLATION; technician or service company.
Safety Information Safety Infor mation 4 English FOR INSTALLATION WARNING Use the power line with the power specifications of the product or higher and use the power line for this appliance only. In addition, do not use an extension line. • Extending the power line may result in electric shock or fi...
Page 5 - CAUTION; Avoid adding drain to waste pipes as odours may arise in the future.; that draining is performed correctly.; may overflow and result in property damage.; the power line into the space behind the appliance.; This may result in electric shock or fire.
Safety Infor mation 5 English CAUTION Install your appliance on a level and hard floor that can support its weight. • Failing to do so may result in abnormal vibrations, noise, or problems with the product. Install the drain hose properly so that water is drained correctly. • Failing to do so may re...
Page 6 - thunder/lightning storm, cut the power at the circuit breaker.; FOR USING
Safety Information Safety Infor mation 6 English CAUTION When not using the air conditioner for a long period of time or during a thunder/lightning storm, cut the power at the circuit breaker. • Failing to do so may result in electric shock or fire. FOR USING WARNING If the appliance is flooded, ple...
Page 8 - the power supply and contact the nearest service center.; Failing to do so may result in electric shock or fire.; Do not place objects or devices under the indoor unit.; Failing to do so may result in injury, death or property damage.; is measured according to ISO standard for energy efficiency.; It may cause gas leakage.; Do not install the product in a ship or a vehicle (such as a campervan).
Safety Information Safety Infor mation 8 English If any foreign substance such as water has entered the appliance, cut-off the power supply and contact the nearest service center. • Failing to do so may result in electric shock or fire. Do not attempt to repair, disassemble, or modify the appliance ...
Page 10 - maintenance shall not be made by children without supervision.; FOR CLEANING; wait until the fan stops.; unit since it has sharp edges.; and Maintaining’ section.
Safety Information Safety Infor mation 10 English For use in Europe: This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning ...
Page 11 - Indication
At a Glance 11 English Indoor Unit Overview At a Glance 1WAY (PC1BWFMAN) 02 01 04 05 03 01 Display 02 Remote control sensor 03 Airflow blade 04 Wind-Free panel (You can use the Wind-Free Cooling function when the Cool, Dry, or Fan mode is running.) (Refer to the remote control manual for product ope...
Page 13 - Operation Features; Model
At a Glance 13 English Operation Features Operating temperature and humidity Model Mode Outdoor temperature Indoor temperature Indoor humidity AC026RN1DKGAC035RN1DKG Cool mode -15°C to 46°C 18°C to 32°C 80% or less Heat mode -20°C to 24°C 30°C or less - Dry mode -15°C to 46°C 18°C to 32°C 80% or les...
Page 14 - Cleaning the indoor unit exterior; Cleaning the outdoor unit heat exchanger; Spray water to clean the dust.
Cl eaning and Maint enanc e 14 English Cleaning and Maintaining Cl eaning and Maint enanc e Cleaning and Maintaining Cleaning the indoor unit exterior 1WAY Wipe the surface of the unit with a slightly wet or dry cloth when needed. Wipe off dirt of odd- shaped areas by using a soft brush. CAUTION • D...
Page 15 - Push
Cl eaning and Maint enanc e 15 English Cl eaning and Maint enanc e Cleaning the air filter CAUTION • Before cleaning the indoor unit, be sure to turn off the auxiliary power switch. • Be sure to hold the grille with a hand to prevent dropping from the opening of the front grille. 1WAY (PC1BWFMAN) 1 ...
Page 16 - NOTE
Cl eaning and Maint enanc e 16 English Cleaning and Maintaining Cl eaning and Maint enanc e 2 Cleaning the air filter Clean the air filter with a vacuum cleaner or soft brush. If dust is too heavy, then rinse it with running water and dry it in a ventilated area. CAUTION Do not scrub the air filter ...
Page 17 - Filter Reset
Cl eaning and Maint enanc e 17 English Cl eaning and Maint enanc e 4 Resetting the air filter After cleaning and reassembling the air filter, be sure to reset the filter-cleaning reminder as follows: • Indoor unit with the wired remote control: Press the Filter Reset button. • Indoor unit with the w...
Page 19 - Reassembling the air filter; If the indoor unit is used without the air filter,
Cl eaning and Maint enanc e 19 English Cl eaning and Maint enanc e 3 Reassembling the air filter CAUTION • If the indoor unit is used without the air filter, the indoor unit may be damaged due to dust. DB68-08166A-05_IB_CAC R32 Universal Wind Free 1,4way_EU_EN.indd 19 2024-01-18 오전 9:52:29
Page 21 - Periodical maintenance; Unit
Cl eaning and Maint enanc e 21 English Cl eaning and Maint enanc e Periodical maintenance Unit Maintenance item Interval Requires qualified technicians Indoor unit Clean the air filter. At least once a month Clean the condensate drain pan. Once a year Required Clean up the heat exchange. Once a year...
Page 22 - Troubleshooting
Cl eaning and Maint enanc e 22 English Cleaning and Maintaining Cl eaning and Maint enanc e Troubleshooting Refer to the following chart if the air conditioner operates abnormally. This may save time and unnecessary expense. Problem Solution The air conditioner does not operate immediately after it ...
Page 25 - Technical specifications; Type; • This indoor unit can be connected to an R-32 or R-410A outdoor unit.
Cl eaning and Maint enanc e 25 English Technical specifications Type Model Net weight(kg) Net dimension(W x D x H) (mm) Indoor unit AC026RN1DKG/EU 9.2 970 x 410 x 135 AC035RN1DKG/EU 9.2 970 x 410 x 135 AC052RN4DKG/EU 14.5 840 x 840 x 204 AC071RN4DKG/EU 14.5 840 x 840 x 204 AC100RN4DKG/EU 18.0 840 x ...
Page 26 - QUESTIONS OR COMMENTS?
COUNTRY CALL OR VISIT US ONLINE AT UK 0333 000 0333 www.samsung.com/uk/support IRELAND (EIRE) 0818 717100 www.samsung.com/ie/support GERMANY 06196 77 555 77 www.samsung.com/de/support FRANCE 01 48 63 00 00 www.samsung.com/fr/support SPAIN 91 175 00 15 www.samsung.com/es/support PORTUGAL 210 608 098 ...