Page 2 - English; Contents; Safety Information; Installation Procedure
2 English Contents Safety Information 3 Safety Information 3 Installation Procedure 6 Installation Procedure 6 Step 1 Checking and preparing accessories 6 Step 2 Choosing the installation location 6 Step 3 Installing the indoor unit 9 Step 4 Purging inert gas from the indoor unit 10 Step 5 Connectin...
Page 3 - mation; WARNING: Read This Manual; Notices and notes; IMPORTANT; NOTE; The user and installer guides should be read carefully.; WARNING
3 English Safety Infor mation WARNING: Read This Manual • Read and follow all safety information and instructions before installation, use, or maintenance of this appliance. Incorrect installation, use, or maintenance of this appliance can result in death, serious injury, or property damage. Keep th...
Page 4 - General information; Installing the unit
4 Safety Information English Safety Infor mation General information WARNING • Carefully read the content of this manual before installing the air conditioner and store the manual in a safe place in order to be able to use it as reference after installation. • For maximum safety, installers should a...
Page 5 - Power supply line, fuse or circuit breaker
5 English Safety Infor mation • Do not install the product in a ship or a vehicle (such as a campervan). Salt, vibration or other environmental factor may cause the product malfunction, electric shock or fire. • Our units should be installed in compliance with the spaces shown in the installation ma...
Page 6 - Instal; Step 1 Checking and preparing; Installation location requirements
6 English Instal lation Pr oc edure Step 1 Checking and preparing accessories The following accessories are supplied with the indoor unit. The type and quantity may differ, depending on the specifications. User manual (1) Installation manual (1) Insulation Install Outlet (1) Insulation Install SVC (...
Page 7 - Do not install the air conditioner in following; Indoor unit installation requirement; CAUTION
7 English Instal lation Pr oc edure 4.2 11.2 4.4 12.3 4.6 13.4 4.8 14.6 5.0 15.8 5.2 17.1 5.4 18.6 5.6 20.0 5.8 21.5 6.0 23.0 • m : Total refrigerant charge in the system• A : Minimum required room area • IMPORTANT: it’s mandatory to consider either the table 1 or taking into consideration the local...
Page 8 - Indoor unit dimensions
8 Installation Procedure English Instal lation Pr oc edure Indoor unit dimensions AC026BNJPKG,AC035BNJPKG (Unit: mm) 199 16 65 720 30 96 48 89 103 68 18 620 128 104 104 153 75 01 02 03 04 No. Name Description 01 Liquid pipe connection Ø6.35 (1/4") 02 Gas pipe connection Ø9.52 (3/8") 03 Drain...
Page 9 - Step 3 Installing the unit
9 English Instal lation Pr oc edure Step 3 Installing the unit 1 When you install the indoor with side-pipe connection, please make space more than 300mm from the wall. A A A : 300 mm 2 When you install the indoor at the inclined floor, please lean the set toward the drain hose and pipe connection t...
Page 10 - Step 4 Purging inert gas from the indoor; Step 5 Connecting the assembly pipes
10 Installation Procedure English Instal lation Pr oc edure 7 Hanging the indoor unit on the Bracket Hanger, then fix the Indoor Unit by using 4 Screws.• Case 1. Installing on the floor: You must secure the unit to the wall using 4 screws to ensure that the unit does not fall. • Case 2. Hanging on t...
Page 11 - Step 6 Cutting and flaring the pipes
11 English Instal lation Pr oc edure 2 Use insulation that is thick enough to cover the refrigerant pipe to prevent condensate water on the outside of pipe and to ensure system efficiency. Condensation can drip onto the floor causing property damage or a slip hazard. 3 Cut off any excess foam insula...
Page 12 - Step 7 Performing the gas leak test; Step 8 Insulating the refrigerant pipes
12 Installation Procedure English Instal lation Pr oc edure 5 Check that the flaring is correct, referring to the illustrations below for examples of incorrect flaring. Correct Inclined Damaged Surface Cracked Uneven Thickness CAUTION • If the pipes require brazing ensure that OFN (Oxygen Free Nitro...
Page 13 - Step 9 Installing the drain hose and
13 English Instal lation Pr oc edure 5 Select the insulation of the refrigerant pipe.• Insulate the gas side and liquid side pipe, noting the insulation thickness that must differ according to the pipe size. • Standard: Less than an indoor temperature of 30°C, with humidity at 85%. If installing in ...
Page 14 - Step 10 Optional : Half concealed
14 Installation Procedure English Instal lation Pr oc edure 6-ways for drain hose and drain pipe connection Knock out NOTE • The hose will be fixed permanently into position after finishing the installation and the gas leak test; refer to page 12 for further details. Step 10 Optional : Half conceale...
Page 15 - Step 12 Optional: Extending the power
15 English Instal lation Pr oc edure Indoor power supply Power supply Max/ Min(V) Indoor power cable 220 to 240V, 50 Hz ±10% 0.75 mm²↑, 3 wires Communication cable 0.75 mm²↑, 2 wires 10.1 11.4 14 AC power,Communication: M4 screw (Unit: mm) Tightening torque (kgf • cm) M4 12.0 to 18.0 • 1 N·m = 10 kg...
Page 19 - Control and External Floating switch
19 English Instal lation Pr oc edure Step 14 Optional : Connecting the External control (MIM-B14), Wired Remote Control and External Floating switch After disassembling the body front and cover plate, you can connect the wires from the indoor unit' electrical component box to the External control(MI...
Page 20 - Step 15 Setting the indoor unit; Common steps for setting the addresses and
20 Installation Procedure English Instal lation Pr oc edure Step 15 Setting the indoor unit addresses and the installation options • Set the indoor unit address and installation option with a wireless remote controller. Options and address can also be modified using wired controllers or service soft...
Page 25 - Setting the installation options in a batch
25 English Instal lation Pr oc edure Example) If you want to set as "MAIN: 3, CHANNEL: 1, RMC: B", SEG1 SEG2 SEG3 SEG4 SEG5 SEG6 0 A 1 - - 3 SEG7 SEG8 SEG9 SEG10 SEG11 SEG12 1 - 1 - 1 B assign option codes except SEG 1, 7 which are page options. Setting the installation options in a batch In...
Page 28 - Appendix; Appendix
28 Troubleshooting English Appendix Troubleshooting Appendix • If an error occurs during the operation, one or more LED flickers and the operation is stopped except the LED.• If you re-operate the air conditioner, it operates normally at first, then detect an error again. Abnormal condition Error co...