Samson 2190 - Manual
Samson 2190 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – Table of Contents
- Page 3 – PICTORAL DIAGRAM OF RF
- Page 6 – Select; INI CNF MET REP; Choose which menu option is desired
- Page 13 – Action: Create hose screen is displayed; If a RF Meter is deleted, the Delete Hose screen is displayed
- Page 16 – Clearing Transactions from Keypad Memory:; The selection is in reverse video
- Page 18 – 6 numeric digit field
- Page 19 – seconds; Press Enter key to move to Hose Inactive Timeout Option; Press Enter key to move to Display Timeout Option
- Page 21 – Use scroll key to select the external printer setting; Use numeric keys to enter the new password then press enter.; Action: reenter new password to confirm.
- Page 23 – Use the scroll key to select report option
- Page 25 – Use scroll key to move to CNF and press Enter key
- Page 26 – Communications Report:; COMMUNICATION REPORT
- Page 27 – DD; STATISTICAL REPORT BY USER
- Page 28 – STATISTICAL REPORT BY PRODUCT; STATISTICAL REPORT BY RF METER; Action: After printing the Select Report Screen is displayed
- Page 29 – STATISTICAL REPORT TANK
- Page 31 – Fluid Type Definitions; Fluid id; Maximum Fluid types is 8
- Page 32 – Maximum of 8 Tanks
- Page 33 – Hose/Meter Definitions; Maximum of 48 Hose/Meters
- Page 35 – The User Name is up to 16 characters
The Samson RFX is designed to control and monitor the consumption
and inventory balances of automotive fluid products with minimal
installation and programming costs. The wall mounted keypad module
consists of a 12-button keypad, LCD display and integral ticket printer.
The RFX keypad can control up to 48 meters and track 8 different
fluids and tanks. It is capable of sending and receiving data typically
up to 300 feet in a service facility installation. A unique, patented
feature of the control system is that the dispense trigger of the RFX
Meter is locked until authorization from the keypad is received. After
the dispense is completed, the user can top off the dispense and the
actual amount used is sent back to the keypad and this meter returns
to the locked status. Additionally, the meter can be installed on
portable dolly systems offering control and monitoring of often high-
cost lubrication products. Up to 50 operators can be defined with their
own unique PIN number for accessing the system. The system
provides dispense reports by operator, fluid type, meter or tank. This
allows for flexibility in reviewing system activity.
The operator enters his PIN number and selects the hose that the fluid is to be dispensed from.
The operator then enters the required quantity and presses ENTER to confirm. The meter is then
authorized to automatically dispense and shut off when the authorized amount of fluid is
dispensed. The operator may then top off the vehicle for the proper fill, if necessary. The operator
may allow the meter to “time out” or may depress “Reset” which sends all actual dispense data
back to the keypad and puts the meter into a secure “Locked” status until the next authorized
dispense work order is received from the keypad. After each dispense, a transaction ticket is
printed showing the fluid and quantity dispensed along with the operator's name.
Mount the keypad to the wall either inside the shop on a wall facing the shop. In either case
mount the included remote antenna INSIDE the shop up high on the wall with line of sight to all
the meters.
Range is 300 feet unobstructed, be sure to test the keypad/antenna mounting position with a 2188
meter at all positions in the shop, and try to simulate a ‘worst case scenario’ with vehicle
obstructions during testing. Performing this important step will ensure trouble-free service for the
End User and no callbacks for the Installer.
RFX Keypad
Parts and Technical Service guide
Guía de servicio técnico y recambio
Guide d’instructions et pièces de rechange
Ref.:
Model 2190
2190
1
Description/ Descripción/ Description
E
Operation/ Modo de empleo/ Mode d’emploi
E
Installation and Configuration
E
Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
Table of Contents Diagram of RF X Logical Set-up ....... ...................................................................................3 Keyboard Description ..........................................................................................................4 Default Screens ................
PICTORAL DIAGRAM OF RF X LOGICAL SET-UP Samson Corporation-Swannanoa, NC 28778 800.311.1047 www.samsoncorporation.com
Management Menu: The management menu displays after entering the supervisor PIN Number Select INI CNF MET REP 190 - - - - - - - - - Active keys: , , Action: • Choose which menu option is desired Screens in INI can be accessed only when the Dispense Order list is empty. If the supervisor wants to cha...