PRODUCT MODEL NUMBERS

OVERALL DIMENSIONS

VENTING REQUIREMENTS

MHE14X

Electrical:

A 120-volt, 60-Hz, AC-only, 15- or 20-

amp. electrical supply located in the upper cabinet
as close as possible to the microwave oven hood.
A time-delay fuse or circuit breaker and separate
circuit is recommended.

Microwave Hood Combination

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. 8184732

04-21-03

Recommended standard fittings

If the existing vent is round, a rectangular-
to-round adapter must be used and a
rectangular 3" extension vent between the
damper assembly and the adapter must be
installed to prevent sticking of the exhaust
damper.

1 - 3-1/4" x 10"

90° elbow

= 25 ft.

1 - wall cap

= 40 ft.

8 feet straight

= 8 ft.

Length of
3-1/4" x 10" system

= 73 ft.

6" vent system

3-1/4" x 10" vent system

1 - transition

= 5 ft.

2 - 90° elbows

= 20 ft.

1 - wall cap

= 40 ft.

8 feet straight

= 8 ft.

Length of 6" system

= 73 ft.

3-1/4" x 10"
90° elbow

90° elbows

transition

wall cap

6 ft.

2 ft.

6 ft.

2 ft.

3-1/4" x 10"
to 6" = 5 ft.

3-1/4" x 10"
roof cap = 24 ft.

3-1/4" x 10"
90

°

elbow = 25 ft.

90

°

elbow

= 10 ft.

3-1/4" x 10"
wall cap =
40 ft.

3-1/4" x 10"
flat elbow =
10 ft.

45

°

elbow

= 5 ft.

Recommended vent length

Use 3-1/4" x 10" or 6" vent. The total length of the vent system
including straight vent, elbow, transitions, wall or roof caps
must not exceed the equivalent of 140 feet of
3-1/4" x 10" rectangular or 6" diameter round vent. For best
performance, use no more than three 90° elbows. To calculate
the length of system you need, add the equivalent feet for
each vent piece used in the system. See examples below.

NOTE:

There must be

at least one wall stud
within cabinet
opening.

Roof venting

Wall venting

roof cap

3-1/4" x 10"

through-the-roof

3-1/4" x 10"

through-the-wall

wall cap

CABINET OPENING DIMENSIONS

For wall or roof venting methods:

If the wall exhaust method is chosen, be sure that
there is proper clearance within the wall for the
exhaust vent.

Wall and roof caps must have back-draft damper.
We recommend:

using rigid metal vent.

that length of vent and number of elbows should
be kept to a minimum to provide efficient
performance.

that size of vent should be uniform.

using duct tape to seal all joints in the vent
system.

using caulking compound to seal exterior wall or
roof opening around cap.

two elbows should not be installed together.

We do NOT recommend:

flexible metal vent.

NOTE:

If flexible metal vent must be used, calculate

each foot of flexible metal vent as two feet of rigid
metal vent. Flexible metal elbows count twice as
much as standard elbows.

16-1/4"

29-7/8"

15-3/8"

66" min.

top of wall

mounting plate

to floor

30" min.

to cooking

surface

below

microwave

hood

30" min. cabinet
opening width.

12" to 14" recommended
cabinet depth

wall studs

®