Table of Contents:

  • Page 2 – Installation Instructions; Do not use substitute; National; DANGER
  • Page 3 – TOOLS YOU WILL NEED; Your installation components may vary.; PARTS PROVIDED; OTHER TOOLS THAT MIGHT BE REQUIRED
  • Page 4 – DIMENSIONS; DESCRIPTION
  • Page 5 – PLANNING FOR VENTING; INTAKE/EXHAUST GUIDELINES
  • Page 6 – FLUE TERMINAL CLEARANCES; CLEARANCES PER
  • Page 7 – ADDITIONAL CLEARANCES – VENT TERMINAL; Local codes supersede these clearances.
  • Page 8 – FLUE INSTALLATION – CONDENSATE DRAIN; HORIZONTAL TERMINATION WITH
  • Page 9 – PLANNING FOR PLUMBING
  • Page 10 – CORROSIVE ATMOSPHERES; Reinforcement of the; Specification; CLEARANCES FOR WATER HEATER; Combustible
  • Page 11 – ON MASONRY OR CEMENT WALL:
  • Page 12 – PIPE SIZING PROCEDURE; GAS PIPING; GENERAL INSTRUCTIONS; Specifications; CONNECTING THE WATER HEATER TO GAS AND WATER; PIPE SIZING TABLE – NATURAL GAS
  • Page 13 – Use a pipe wrench to securely
  • Page 14 – WATER PIPING; Cleaning the inlet; PRESSURE RELIEF VALVE; American National Standard (ANSI; INTERNAL BUILT-IN FREEZER PROTECTION
  • Page 15 – MNPT connection at the bottom of; SUPPLEMENTAL FREEZE PROTECTION
  • Page 16 – RECOMMENDED PIPING FOR BASIC INSTALLATION; KEY
  • Page 18 – To reduce the risk; • Do not use an extension cord or an adapter plug; ELECTRICAL REQUIREMENTS; WARNING –; This water heater is
  • Page 19 – MAXIMUM VENT LENGTH; VENT LENGTH CALCULATIONS; VENTING INSTRUCTIONS; CONDENSATE; If the condensate
  • Page 20 – VENT PRODUCTS; Ubbink; FLUE INSTALLATION – CONCENTRIC VENTING; MANUFACTURER
  • Page 21 – HIGH ALTITUDE INSTALLATIONS; Do not adjust the other; CASCADING MULTIPLE WATER HEATERS; GUIDELINES; • Do not install the Dual Connect Cable Kit (AGTDC1)
  • Page 22 – REMOTE CONTROLLER INSTALLATION; LOCATION; MOUNTING THE CONTROLLER
  • Page 23 – CLEANING THE INLET FILTER; INSTALLATION CHECKLIST; MUST NOT
  • Page 24 – TECHNICAL DATA; PRESSURE DROP CURVE
  • Page 25 – LADDER DIAGRAM
  • Page 26 – Notes
Loading the manual

1

49-50229-1 03-08 JR

Installation

Indoor Direct Vent Tankless Water Heater

Instructions

Models GN75DNSRSA, GN94DNSRSA, GP94DNSRSA

Questions? Call 888.HOTWTER (888.468.9837) or Visit our website at ge.com

BEFORE BEGINNING INSTALLATION

Read these instructions completely and carefully.

IMPORTANT

Save these instructions

for local inspector ’s use.

IMPORTANT

Observe all governing

codes and ordinances.

Note to Installer –

Be sure to leave these

instructions with the Consumer.

Note to Consumer –

Keep these instructions

for future reference.

• Proper installation is the responsibility of the

installer.

• Product failure due to improper installation

is not covered under the Warranty.

Recognize this symbol as an indication
of Important Safety Information!

WARNING:

Read entire manual. Failure to follow all guides and rules could cause personal

injury or property damage.

• Check with your state and/or local public works department for plumbing codes. You must follow their

guides as you install the Water Heater.

NOTE: Failure to comply with these installation instructions will void the product warranty, and the
installer will be responsible for any service, repair or damages caused thereby.

SAFETY PRECAUTIONS

WARNING:

If the information in these

instructions is not followed exactly, a fire or explosion
may result , causing property damage, personal injury
or death.

FOR YOUR SAFETY!

– Do not store or use gasoline or other

flammable vapors or liquids or other
combustible materials in the vicinity of this
or any other appliance. To do so may result
in an explosion or fire.

– WHAT TO DO IF YOU SMELL GAS

• Do not try to light any appliance.
• Do not touch any electrical switch;

do not use any phone in your building.

• Immediately call your gas supplier from a

neighbor’s phone. Follow the gas supplier’s
instructions.

• If you cannot reach your gas supplier,

call the fire department .

• Do not return to your home until authorized

by the gas supplier or fire department .

– Improper installation, adjustment , alteration,

service or maintenance can cause property
damage, personal injury or death. Refer to
this manual. Installation and service must
be performed by a qualified installer, service
agency or the gas supplier.

• This water heater must be vented outdoors

using approved ducting materials.

• Service information and wiring diagram are

located behind front panel.

• Service must be performed by a qualified

service agency.

• This appliance must be properly grounded and

installed as described in these instructions.

FOR INDOOR APPLICATIONS ONLY

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - Installation Instructions; Do not use substitute; National; DANGER

Installation Instructions 2 SAFETY PRECAUTIONS (cont .) WARNING: Do not use substitute materials. Use only parts certified with theappliance. • This appliance must be installed, inspected and leak tested by a state- or city-qualified licensedcontractor. It is the responsibility of the personhaving t...

Page 3 - TOOLS YOU WILL NEED; Your installation components may vary.; PARTS PROVIDED; OTHER TOOLS THAT MIGHT BE REQUIRED

3 Installation Instructions TOOLS YOU WILL NEED • Pipe Wrenches (2) • Gloves • Adjustable Pliers • Safety Glasses • Screwdrivers (2) • Wire Cutters MATERIALS YOU WILL NEED TO SUPPLY • Soap Solution • Pipe Fittings Required: • Pipe Compound – Unions • Approved Venting – Ball Valves • 5/8 ″ ID PVC Fle...

Page 4 - DIMENSIONS; DESCRIPTION

4 Installation Instructions DIMENSIONS *This is the minimum dimension from the wall. The wall bracket is adjustable to allow an additional 1.57 inches (40 mm). GN75/GN94/GP94DNSRSA DIM. DESCRIPTION IN. (MM) A Width 14 (355.6) B Depth 9 5 ⁄ 8 (244.5)* C Height – Unit 22 7 ⁄ 8 (582) D Height – with br...

Other Rheem Models