Table of Contents:

  • Page 2 – PATENTS; Rheem Australia Pty Ltd.; TRADE MARKS; Registered trademark of Rheem Australia Pty Ltd.; Notice to Victorian Customers from the
  • Page 3 – CONTENTS; HOUSEHOLDER – We recommend you read pages 4 to 13.
  • Page 4 – ABOUT YOUR WATER HEATER; MODEL TYPE
  • Page 5 – HOW HOT SHOULD THE WATER BE?; aerosols, stain removers and household chemicals; near the water heater whilst it is
  • Page 6 – “To Turn Off The Water Heater”; Refer to; . If you are not
  • Page 7 – ENVIRONMENT
  • Page 8 – REGULAR CARE; TEMPERATURE PRESSURE RELIEF VALVE; It is very important you raise and lower; Failure to do this may result in the water heater; It is very important you; The expansion control valve should be checked for performance or
  • Page 9 – WATER SUPPLIES; CHANGE OF WATER SUPPLY
  • Page 11 – SAVE A SERVICE CALL; “Heat Pump Is Not Operating”
  • Page 12 – HEAT PUMP IS NOT OPERATING; Time controlled power supply; Has the thermal cut out for the heat pump compressor activated?; Heat pump fault; Has the heat pump developed a fault?
  • Page 13 – TEMPERATURE PRESSURE RELIEF VALVE RUNNING; Normal Operation; “Temperature Pressure Relief Valve”; Steady flows for long periods (often at night); HIGHER THAN EXPECTED ELECTRICITY BILLS
  • Page 14 – INSTALLATION; STORAGE TANK AND HEAT PUMP MODULE; Do not; WATER HEATER LOCATION
  • Page 15 – dimensions diagram; TANK WATER SUPPLY
  • Page 16 – HOT WATER DELIVERY; Two Temperature Zones Using a Temperature Limiting Device
  • Page 17 – CIRCULATED HOT WATER FLOW AND RETURN SYSTEM; Temperature Limiting Device; Circulated Hot Water Flow and Return System
  • Page 18 – REDUCING HEAT LOSSES
  • Page 19 – TYPICAL INSTALLATON – OUTDOOR LOCATION; TYPICAL INSTALLATION
  • Page 20 – HEAT PUMP DIMENSIONS; Storage tank 87 kg
  • Page 21 – HEAT PUMP AND TANK ASSEMBLY
  • Page 22 – ASSEMBLY PROCEDURE; Step 1
  • Page 23 – Air Louvre Removal:; Remove the louvres from the heat pump module.
  • Page 24 – Heat Pump Module Placement:; Using; two; people, one person on each lifting bar, lift the heat pump; Heat Pump Module Attachment:; Remove the two (2) lifting bars and attach the heat pump module to; Water Fitting Caps:; tank. These may be unscrewed or cut from the fittings if necessary.
  • Page 25 – Inlet Flexible Braided Hose:; Outlet Flexible Braided Hose:; Tighten the swivel nut on the hose using a 24 mm spanner.
  • Page 26 – CONTROL BOARD HEAT PUMP with; open air bleed valve screw; Tank Sensor Cable Connection:
  • Page 27 – “Connections – Plumbing”; Air Louvre Attachment:; “Connections – Electrical”
  • Page 28 – CONNECTION SIZES
  • Page 29 – EXPANSION CONTROL VALVE
  • Page 30 – and a satisfactory megger reading is obtained.
  • Page 31 – WIRING DIAGRAM; Electrical Circuit for Heat Pump
  • Page 32 – MULTIPLE INSTALLATIONS; The water heaters must be of the same model.
  • Page 33 – TYPICAL INSTALLATION – MULTIPLE HEAT PUMP WATER HEATERS; MULTIPLE HEAT PUMP WATER HEATERS; MULTIPLE HEAT PUMP WATER HEATERS INSTALLATION DIMENSIONS; Notes; In Line Manifold
  • Page 34 – MANIFOLD ARRANGEMENT; Hot Manifold Assembly; Manifold Arrangement - Multiple Installation; Cold Manifold Assembly
  • Page 35 – COMMISSIONING; TO FILL AND TURN ON THE WATER HEATER
  • Page 36 – DRAINING THE WATER HEATER
  • Page 37 – This page is intentionally blank.
  • Page 39 – RHEEM HEAT PUMP WATER HEATER WARRANTY; WARRANTY CONDITIONS; WARRANTY EXCLUSIONS
  • Page 40 – WARRANTY – HEAT PUMP WATER HEATER MODEL 551310; Rheem will; RHEEM AUSTRALIA PTY LTD; FOR SERVICE TELEPHONE
Loading the manual

This water heater must be installed and serviced by an authorised person.

Please leave this guide with the householder.

Owner’s Guide

and

Installation Instructions

Air Sourced 310 Heat Pump

Water Heater

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Summary

Page 2 - PATENTS; Rheem Australia Pty Ltd.; TRADE MARKS; Registered trademark of Rheem Australia Pty Ltd.; Notice to Victorian Customers from the

PATENTS This water heater may be protected by one or more patents or registered designs in the name of Rheem Australia Pty Ltd. TRADE MARKS ® Registered trademark of Rheem Australia Pty Ltd. ™ Trademark of Rheem Australia Pty Ltd. Note: Every care has been taken to ensure accuracy in preparation of ...

Page 3 - CONTENTS; HOUSEHOLDER – We recommend you read pages 4 to 13.

3 CONTENTS HOUSEHOLDER – We recommend you read pages 4 to 13. The other pages are intended for the installer but may be of interest. About Your Water Heater ............................................................................................................ 4 Regular Care ......................

Page 4 - ABOUT YOUR WATER HEATER; MODEL TYPE

4 ABOUT YOUR WATER HEATER MODEL TYPE Your Rheem ® air sourced heat pump water heater is designed for outdoor installation only. The model you have chosen is a 551 series model. The 551 310 model heat pump water heater is recommended for connection to a minimum 16 hour per day power supply. A Rheem h...

Other Rheem Models