Rheem 40-33(NAT)- User Manual

Rheem 40-33(NAT)

Rheem 40-33(NAT)– User Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.

1 Page 1
Page: / 1
Loading the manual

Rheem PowerVent

Induced Draft Gas Water Heater with the Guardian System

Guardian System

Air / fuel shut-off system offers double
protection

Maintenance free –
no filter to clean

Flammable
Vapour Detection Sensor

Protective control system
that disables the heater in
the presence of flammable
vapour accumulation

Flexible Venting
Options

Long venting lengths up to 100 feet

PVC, ABS, or CPVC vent pipe options

Vertical or horizontal termination

New Quiet Blower

Less noise than ever before

Self-Diagnostic
System

Integrated self-diagnos-
tic system control takes
the guess work away

Environmentally
Friendly Burner

Low NOx design for low
nitrous oxide emissions

High Altitude Compliant

Models certified up to 4,500 feet above
sea level

Self-Cleaning

EverKleen

patented system fights

sediment build-up

Reduces fuel costs

Provides more hot water

Longer Life

Patented magnesium anode rod design
incorporates a special resistor that
protects the tank
from corrosion.

Provides longer
tank life than using
standard magnesium
anode rods

*

* See Residential Warranty Information Brochure for

complete warranty information.

HOT

WATER

CONNECTION

COLD

WATER

CONNECTION

POWER VENT

ASSEMBLY

C

B

F

A

D

G

G

E

T&P FITTING

3/4" N.P.T.

1/2"

DESCRIPTION

FEATURES

ROUGHING IN DIMENSIONS (SHOWN IN INCHES)

ENERGY INFO.

NEW

HT. TO

HT. TO

WATER

HT. TO

WATER

PREVIOUS

FVIR

FIRST HOUR

TOP OF

TANK

GAS

CONN.

SIDE T&P

CONN.

SHIP.

ENERGY

GALLON / LITRE

MODEL

MODEL

GAS INPUT IN

RECOVERY IN

DEL. G.P.H.

ASSEMBLY

HT.

DIAM.

CONN.

CNTR.

VALVE

SIZE

WT.

FACTOR

CAPACITY

NUMBER

NUMBER

THOUS. BTU/HR.

G.P.H. 100° RISE

NAT.

A

B

C

D

E

F

G

(LBS)

NATURAL

40 / 151

PVS40-36

PVS40-36FV

36

30.5

67

61-1/2

50-1/2

20-1/4

14

8

44

3/4

152

0.59

40 / 151

PVS40-36P

PVS40-34PFV

34

28.8

67

61-1/2

50-1/2

20-1/4

14

8

44

3/4

152

0.59

50 / 189

PVS50-36

PVS50-36FV

36

30.5

80

61-1/2

50-1/2

22-1/4

14

8

44

3/4

176

0.58

50 / 189

PVS50-36P

PVS50-34PFV

34

28.8

80

61-1/2

50-1/2

22-1/4

14

8

44

3/4

176

0.58

CROSS REFERENCE AND SPECIFICATIONS

VENTING INFORMATION FOR 2" VENTS

NUMBER OF

MINIMUM

MAXIMUM

90° ELBOWS

NUMBER

PIPE PIPE

WITH VENT

OF 45°

LENGTH

LENGTH

TERMINAL

ELBOWS

REQ. (FT.)

(FT.)

One (1)

None

4.0

44.0

One (1)

One (1)

4.0

41.0

Two (2)

None

4.0

38.0

Two (2)

One (1)

4.0

35.0

Three (3)

None

4.0

32.0

For the 2" vent, one 90° elbow is approximately equal to
6 feet of pipe. One 45° elbow is approximately equal to
3 feet of pipe.

VENTING INFORMATION FOR 3" VENTS

NUMBER OF

MINIMUM

MAXIMUM

90° ELBOWS

NUMBER

PIPE PIPE

WITH VENT

OF 45°

LENGTH

LENGTH

TERMINAL

ELBOWS

REQ. (FT.)

(FT.)

One (1)

None

5.0

95.0

One (1)

One (1)

5.0

92.5

Two (2)

None

5.0

90.0

Two (2)

One (1)

5.0

87.5

Three (3)

None

5.0

85.0

Three (3)

One (1)

5.0

82.5

Four (4)

None

5.0

80.0

Four (4)

One (1)

5.0

77.5

Five (5)

None

5.0

75.0

For the 3" vent, one 90° elbow is approximately equal to
5 feet of pipe. One 45° elbow is approximately equal to
2.5 feet of pipe.

Rheem Manufacturing Company • Water Heater Division
Rheem Canada Ltd./Ltée

,128 Barton Street West, Hamilton, Ontario L8N 3P3

0 9 / 0 6 W P

F O R M N O . 1 0 1 - 8 5 C A N

In keeping with its policy of continuous progress and product improvement, Rheem reserves the right to make changes without notice.

Available in 40 and 50 US Gallon Models

6-Year Limited Tank Warranty*

1-Year Limited Parts Warranty*

®

"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.

Other Rheem Models