Rheem 12 - Manual
Rheem 12 – Manual, read for free online in PDF format. We hope this helps you resolve any issues you may have. If you have further questions, please contact us through the contact form.
Table of Contents:
- Page 2 – RECOVERY CAPACITIES; INPUT; ELECTRICAL CHARACTERISTICS
- Page 3 – MODEL NUMBERS; • Fuse type; IMMERSION THERMOSTATS; DIMENSIONAL INFORMATION; MODEL; inches; inches; SYSTEM SENTINEL; • System Sentinel
- Page 4 – Recommended Specifications:; C O M M E R C I A L; Rheem Water Heating; all models have integral fusing for each element.
PowerPack ASME
Electric Commercial Water Heaters
Available in 12, 20, 30, and 40 Gallon Tank-Type Models
3 KW thru 36 KW
Electric Commercial Water Heaters are suitable for general commercial hot water
applications and are also ideal for point-of-use installations. Small volume ASME
models are designed to meet engineering specifications.
Construction Features:
• System Sentinel
immersion thermostat models employ
an element diagnostic panel, utilizing
light emitting diodes (L.E.D.), corre-
sponding to the number and location
of each heating element. This system
monitors the on-off function of the
electric heating elements.
• Long life ASME tank design
proprietary steel formulation with
high temperature porcelain enamel
to maximize corrosion resistance
resulting in a superior tank design.
• LIFEGUARD heating elements
separate screw-in type elements
feature a stainless steel outer sheath
of INCO-LOY 840, surrounding a
Nichrome wire filament, to resist water
chemical corrosion and burn-out even
in air or sediment…for long element
life and long life performance.
Elements are directly immersed in the
water for maximum recovery efficiency
(98%) and are easily changed by
simply screwing new ones into the
tank.
LIFEGUARD
elements feature
a three (3) year limited warranty.
• Full port, full flow brass drain
valve
• Minimal heat loss design
85% of the tank surface area on all
Rheem-Ruud Commercial Electric
products are insulated with 2-1/2" of
rigid polyurethane foam insulation
providing superior insulating qualities.
Unlike other designs, Rheem-Ruud
Commercial Electrics can achieve 85%
because of the unique compact layout
of the heating elements.
This results
in heat losses less than the energy
used by a 75 watt light bulb during
a 48 hour standby period!
Certifications and Ratings:
• Efficiency
– in accordance with ANSI test procedures, these models tested below
the maximum allowable standby loss levels of ASHRAE Standard 90.1b-2001
(Part of the Federally mandated Energy Policy Act (EPact)). Also exceeds energy
efficiency codes of all states including California Energy Commission (CEC).
• Safety and construction
– These products are design certified by Underwriters
Laboratories (UL) to meet UL standard 1453 as electric booster and commercial
storage tank water heaters. All models are North Carolina and Massachusetts code
compliant.
CERTIFIED FOR A 160 PSI MAXIMUM WORKING PRESSURE.
• ASME construction
– standard on E12A, E20A, E30A, and E40A models.
Continued next page.
208, 240,
277 and 480
Voltages
Immersion
Thermostat
Models
®
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
RECOVERY CAPACITIES Recovery in U.S. Gallons/Hr. (GPH) and Liters/Hr. (LPH) at Various Temperature Rises INPUT EQUIVALENT 40°F 50°F 60°F 70°F 80°F 90°F 100°F 110°F 120°F 130°F 140°F KW BTU/HR. UNITS (22°C) (28°C) (33°C) (39°C) (45°C) (50°C) (56°C) (61°C) (67°C) (72°C) (78°C) 3 10,236 GPH 31 25 21 18...
MODEL NUMBERS • Fuse type the “G” in the model numberrepresents Class G fuses. • UL Sanitation compliance all models are UL Sanitation(NSF5) compliant whenequipped with the optional ring seal kits. E12A, E20A, E30A-(AS39827),E40A-(AS39828) Solid StateLow Water Cut-off – units maybe ordered with prob...
Water heater(s) shall be model ________________, manufactured by RHEEM-RUUD, having electrical input of __________kW and a recovery rate of _____________ GPH at a 100°F temperature rise. Water heater(s) shall have a storage capacity of___________ gallons. Water heater(s) shall have the UL seal of ce...