Page 2 - Included Accessories; Optional Accessories
2 1. Included Accessories The following accessories are included with the unit.Check for any missing items before starting installation. Q’ty Shape Part Tapping Screw (N-0751M only) 1 each Part Shape Q’ty 5 1 Remote Controller (See p. 21) Remote Controller Cord (3m(10')) 1 2. Optional Accessories Th...
Page 3 - Quick Connect Multi System Installation; Typical Plumbing; System Diagram
3 3. Quick Connect Multi System Installation • The Quick Connect Multi System allows the installation of two units together utilizing only the Quick Connect Cord. Typical Plumbing The Quick Connect Cord is 2m (6'). long. Install the units 50 - 450mm (2-18") apart from eachother to ensure the cor...
Page 4 - Before Installation; DANGER
4 N-0751M 199,900 BTU 12,000 BTU 202 4.0 0.65 0 - 2,000 Ft. 0 - 2,000 Ft. (0 - 610 m) 199,900 168,000 168,000 2.0 2.0 0 - 2,000 ft. (0 - 610 m) 2,000 - 4,500 ft * . (610 - 1,370 m * ) 4.4" 4.4" 2.0 192,800 162,800 162,800 2,000 - 4,500 Ft. 2,000 - 4,500 Ft. * (610 - 1,370 m 610 - 1,370 m * )...
Page 5 - Choosing Installation Site
5 5. Choosing Installation Site * Locate the appliance in an area where leakage from the unit or connections will not result in damage to the area adjacent to the appliance or to the lower floors of the structure. When such locationscannot be avoided, it is recommended that a suitable drain pan, ade...
Page 6 - CAUTION
6 • Install in a location where the exhaust gas flow will not be affected by fans or range hoods. • Take care that noise and exhaust gas will not affect neighbors. • Before installing, make sure that the vent termination (or the vent cap in an outdoor installation) will have the proper clearancesacc...
Page 7 - Installation Clearances; Before installing, check for the following:; WARNING
7 6. Installation Clearances Before installing, check for the following: Install in accordance with relevant building and mechanical codes, as well as any local, state ornational regulations, or in the absence of local and state codes, to the National Fuel Gas Code ANSIZ223.1/NFPA 54 – latest editio...
Page 12 - Installation; Securing to the wall
12 Illustration 7. Installation Check 4. Drill holes for the remaining four screws. 5. Hang the unit again by the first screw, and then insert and tighten the remaining four screws. 6. Take waterproofing measures so that water does not enter the building from screws mounting thedevice. • Make sure t...
Page 13 - Vent Pipe Installation
13 • The first vertical run from the top of the heater should be no longer than 0.9m (3'). • Make sure vent pipe is gas tight and will not leak. Use silicon sealant wherever necessary. • Do not common vent or connect more than one appliance to this venting system. • The total vent length including h...
Page 16 - Gas Piping
16 Gas Meter Select a gas meter capable of supplying the entirebtuh demand of all gas appliances in the building. Gas Connection • Do not use piping with a diameter smaller than the inlet diameter of the water heater. • Gas flex lines are not recommended unless they are rated for 199,900 btuh. • Ins...
Page 17 - Gas Line Sizing for a Noritz Gas Water Heater
17 Gas Line Sizing for a Noritz Gas Water Heater Maximum Natur Natural Gas Delivery Capacity in Cubic Feet per Hour (0.60 Specific Gravity, 0.5" WC Pressure Drop) Contact the Gas Supplier for Btu/Cubic Ft. of the Supplied Gas. 1000 BTU/Cubic Ft. is a Typical Value Maximum Liquified P Liquified P...
Page 18 - Water Piping
18 10. Water Piping This appliance suitable for potable water and space heating applications. Do not use this appliance if any part hasbeen underwater. Immediately call a qualified service technician to inspect the appliance and replace any part of thecontrol system and gas control which has been un...
Page 19 - Plumbing Applications; Recirculation System; Heating System
19 11. Plumbing Applications Pump Control Signal (See p. 23) (See p. 23) (See notes for Sizing) Pump Control signal (See p. 23) Recirculation System Pump Fixtures Cold Water Supply Check Valve Hot Water Return Check Valve Pressure Relief Valve Hot Water Shutoff Valve Drain R B W Use Honeywell Aquast...
Page 20 - Electrical Wiring
20 Do not connect electrical power to the unit until all electrical wiring has been completed. 1. Unscrew the junction box and slide it out of the unit..2. Push the power cord through the bottom of the unit.3. Connect the live and neutral wires to the black and white wire in the junction box. 4. Scr...
Page 21 - Remote Controller
21 • Applicable Model Install the remote controller according to the instructions in the Installation Guide (p. 28). * The water heater has been factory set to allow a maximum temperature setting of 50 ° C (122 ° F). To access higher temperature settings through the remote controller, follow the bel...
Page 22 - Remote controller cord
22 1. Leave enough slack so that the remote controller cord will not be damaged if the unit is removed fromthe wall. 2. Remove the front cover of the heater (4 screws).3. Pass the remote controller cord through the wiring throughway and into the unit. 4. Connect the Y terminals at the end of the rem...
Page 23 - Connecting the pump control wire; Pump Wiring
23 PUMP Crimping Terminal WiringThroughway Connecting the pump control wire 1. Leave enough slack so that the pump control wires will stay connected if the unit is removedfrom the wall. 2. Remove the front cover of the heater (4 screws).3. Cut off the connector at the end of the pump control wires. ...
Page 24 - Connecting Quick Connect Cord; Caution
24 Connecting Quick Connect Cord The wire coloring on the Quick Connect Cord willnot be the same as the wire coloring of theconnection plug inside the unit.* The remote controller can be connected to either unit A or B. Caution For Quick Connect Multi System Installationuse a Quick Connect Cord (sol...
Page 25 - Maintenance; Trial Operation
25 (1) Open a hot water fixture and confirm that the Burner On lamp comes on, and that hot water is being produced. (If necessary, repeat until the air in the gas piping is bled out).* White smoke may be noticed from the exhaust vent during cold weather. However, this is not a malfunction of the uni...
Page 26 - Lighting Instructions; Shutdown Instructions
26 Lighting Instructions This water heater does not have a pilot. It is equipped with an ignition device that automatically lightsthe burner.Do not try to light the burner by hand.1. Read the safety information in the installation manual or on the front of the water heater.2. Turn off all electrical...
Page 27 - Dimensions
27 15. Dimensions N-0751M (VIEW FROM TOP) 178mm (7") 115mm (4.5") 70mm (2.8") 261mm (10.3") 186mm (7.3") 181mm (7.1") 180mm (7.1") 122mm (4.8") 62mm (2.4") 36mm (1.4") 10mm (0.4") 10mm (0.4") 11mm (0.4") 10mm (0.4") 120mm(4.7") 119mm (4.7...
Page 28 - Included Parts List; Installation Guide; NORITZ AMERICA CORPORATION; Note
28 Included Parts List Remote Controller RC-7650M Installation Guide For Installers: Read this installation guidecarefully before carrying outinstallation. NORITZ AMERICA CORPORATION Note Do not connect power to the water heater before the remote controller has been properly installed.Recommended in...
Page 30 - Installing the Remote Controller Outdoor Junction Box
30 Installing the Remote Controller Outdoor Junction Box 1. Insert the remote controller wires through the wall pipe and secure the wall pipe to theremote controller. Locate the remote controllerwall packing, slide it over the pipe and wires,and apply it to the rear side of the remote. 2. Drill a 32...
Page 31 - Requêtes auprès des installateurs; Manuel d’installation; ATTENTION; Low NOx; CHAUFFE-EAU À GAZ SANS CUVE; Canada
Les dangers potentiels provenant d’accidents pendant l’installation et l’utilisation sont classés dans lestrois catégories suivantes. Observez bien ces avertissements, ils sont indispensables à votre sécurité. Requêtes auprès des installateurs • Pour assurer une utilisation en toute sécurité de chau...
Page 32 - Accessoires inclus
2 1 de chaque 5 1 1 1 1 1 1 1 1. Accessoires inclus Les accessoires suivants sont inclus avec l’unité.Vérifiez qu’il ne manque aucun élément avant decommencer l’installation. Qté Forme Pièce Pièce Forme Qté Vis autotaraudeuse (N-0751M uniquement) Télécommande (Voir p.21) Cordon de télécommande 3m (1...
Page 33 - Installation du multisystème par raccordement rapide; Schéma du système; Plomberie type
3 G Cordon de télécommande Tuyauterie de distribution en gaz Alimentation en eau froide Eau chaude Télécommande Bornier de raccordement Connecteur du cordon Connecteur du cordon Cordon de raccordement rapide 3. Installation du multisystème par raccordement rapide • Le multisystème à raccordement rap...
Page 34 - Avant l’installation
4 N-0751M 199,900 BTU 12,000 BTU 376 8.01.0 0 - 2,000 Ft. (0 - 610 m) 199,900 168,000 2.0 2.0 192,800 162,800 2,000 - 4,500 Ft. * (610 - 1,370 m * ) 4.4" 14.0" 892 Check-up • Vérifiez les dégâts ou usures des appliques de fixation et du tuyau d’évent chaque année. Remplacez-les au besoin. DA...
Page 35 - Choix du site d’installation; AVERTISSEMENT
5 • Installez la conduite d’évacuation de sorte qu’il n’y ait aucun obstacle autour de la bouche et que le gaz d’échappement ne s’accumule pas. N’entourez pas la bouche de métal ondulé ouautres matériaux. • Evitez les endroits propices à un incendie, comme les endroits où sont manipulés de l’essence...
Page 37 - Dégagement pour l'installation; Avant l’installation, vérifiez les points suivants :
7 AVERTISSEMENT 6. Dégagement pour l'installation Avant l’installation, vérifiez les points suivants : Installez le chauffe-eau conformément aux codes du bâtiment et aux codes mécaniquesapplicables, ainsi qu'aux réglementations locales, de l'état ou nationales, ou en l'absence deréglementation local...
Page 42 - Fixation au mur
12 • Si vous procédez à l’installation à mains nues, prenez garde de ne pas vous blesser. • Faites attention de ne pas toucher le câblage électrique, la conduite de gaz ou eau lors de la perforation des trous. Veillez à l’exécuter. HIGH ELEV AT ION DISCONNECT Illustration 7. Installation Vérificatio...
Page 43 - Installation du tuyau d’évent
13 Fabricant et produit Couvert Découvert Hori. Verti. Hori. Verti. Noritz N-Vent Protech FasNSeal Protech FasNSeal W2 HeatFab SafTVent Z-Flex Z-Vent Flex-L StaR-34 Tuyauterie de l’évent • N’utilisez que les matériaux d’évent de catégorie III présentés ci-dessous. • Suivez les instructions d’install...
Page 46 - Conduite de gaz
16 Noritz chauffe-eau à gaz (199,900 Btuh) Sèche-linge (35,000 Btuh) Barbecue (50,000 Btuh) Gazinière (65,000 Btuh) Cheminée à gaz (25,000 Btuh) **Voir la page suivante pour les tableaux de capacité du tuyau. Instructions Exemple de canalisation du gaz Exemple de calcul Sortie A : 13.5m (45') (Utili...
Page 48 - Conduite d’eau
18 L'installation et l'entretien doivent être assurés par un plombier qualifié.Dans l'état du Commonwealth of Massachusetts, cet appareil doit êtreinstallé par un plombier ou un monteur d'installation au gaz agréésconformément aux sections 2.00 et 5.00 du Massachusetts Plumbing andFuel Gas Code 248 ...
Page 49 - Système de recirculation; Système de chauffage; Plomberie
19 Signal de couplage de la pompe Voir p. 23 (Voir les remarques pour le calibrage) Signal de couplage de la pompe Voir p. 23 (À installer selon les codes locaux) Système de recirculation Pompe Robinets Alimentation en eau froide Clapet à retenue Eau chaude Réservoir de stockage 30-38L (8-10 Gal.) o...
Page 50 - Installation électrique
20 Couper l’alimentation électrique Risque d'électrocutionNe branchez pas le courant à l'unité avant que l'installation électrique ne soit achevée. Débranchez laprise de courant avant de procéder à l'entretien. Le non respect de cette consigne pourrait provoquer une électrocution susceptible d'entra...
Page 53 - Raccordement du câble de commande de la pompe; Câblage de la pompe
23 Pompe de circulation CA 120V Relais (ex. Omron G7L2ABUBJCBAC120) Raccordez aux câbles de commande de la pompe dans l’unité 0 1 2 4 PUMP Borne de sertissage Ouverture pourcâbles Raccordement du câble de commande de la pompe 1. Laissez suffisamment de jeu de sorte que les câbles de commande de la p...
Page 54 - Branchement du cordon de raccordement rapide; Attention
24 Cordon de raccordement rapide "Etiquette du cordon de raccordement rapide" A B 1.Rouge2.Noir3.Blanc4.Vert5.Bleu6.Bleu 1.Rouge2.Noir3.Blanc4.Vert5.Bleu6.Bleu 1.Rouge2.Noir3.Blanc4.Vert5.Bleu6.Bleu 1.Blanc2.Vert3.Rouge4.Noir5.Bleu6.Bleu Branchement du cordon de raccordement rapide L a c o u...
Page 55 - Test de fonctionnement
25 (1) Ouvrez le robinet d’eau chaude et confirmez que le témoin de marche du brûleur est allumé et que l’eau chaude est générée. (Au besoin, répétez jusqu’à ce que l’air dans la tuyauterie du gaz soit purgé).* De la fumée blanche peut être remarquée sortant de la conduite d'évacuation par temps fro...
Page 56 - Manipulation après le test de fonctionnement; Instructions d’allumage; Instructions d’arrêt
26 Le non respect de ces instructions peut être à l'origine d'un incendie ou d'une explosionpouvant provoquer des blessures corporelles ou mortelles, ou des dégâts matériels. ATTENTION AVERTISSEMENT Manipulation après le test de fonctionnement • Si l’unité ne sera pas utilisée immédiatement, fermez ...
Page 58 - Liste des pièces incluses; Guide d’installation; Pour les installateurs :; Remarque
28 Liste des pièces incluses Télécommande RC-7650M Guide d’installation Pour les installateurs : Lisez attentivement ce guided’installation avant de procéderà l’installation. NORITZ AMERICA CORPORATION Remarque Ne branchez pas l’alimentation au chauffe-eau avant que la télécommande ne soit correctem...