Page 2 - one is the Model Number and the other is the; MT; or; Fuel Type; Section 1. Heater Identification Information; Section 1: Heater Identification Information; HEATER IDENTIFICATION INFORMATION — (HIN); HEATER IDENTIFICATION NUMBER
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 2 To identify the heater, see rating plate on the inner front panel of the heater. There are two designators for each heater, one is the Model Number and the other is the Heater Identification Number (HIN). a. Heater Identification Number ...
Page 3 - SPECIAL INSTRUCTIONS TO OWNER:; in this manual applies to all MasterTemp heater models.; READ AND REVIEW THIS MANUAL COMPLETELY,; it; IMPORTANT NOTICES; For the installer and operator of the MasterTemp heater:; The manufacturer’s warranty may be void if, for any; WARRANTY INFORMATION; Specific details are described on the; CAUTION; Section 2: Warning and Safety Instructions; Section 2. Warning and Safety Instructions; IMPORTANT SAFETY INSTRUCTIONS; READ AND FOLLOW ALL INSTRUCTIONS; SAVE THESE INSTRUCTIONS
3 Congratulations on your purchase of the MasterTemp Pool and Spa Heater. Proper installation and service of your new heating system and correct chemical maintenance of the water will ensure years of enjoyment. The MasterTemp heater is a compact, lightweight, efficient, induced-draft, gas fired high...
Page 4 - CONSUMER INFORMATION AND SAFETY; a healthy adult. Special caution is suggested for young children.; WARNING; CODE REQUIREMENTS; Canadian; Section 2. Warning and Safety Instructions; DANGER; CARBON MONOXIDE GAS IS DEADLY –; poisonous gas you cannot see or smell.
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 4 CONSUMER INFORMATION AND SAFETY WARNING The U.S. Consumer Product Safety Commission warns that elevated water temperature can be hazardous. See below for water temperature guidelines before setting temperature. 1. Spa or hot tub water te...
Page 5 - SAFETY INFORMATION; The MasterTemp; must be replaced with an identical control.; CARBON MONOXIDE GAS IS DEADLY; TECHNICIAN, QUALIFIED IN POOL HEATER INSTALLATION.
5 SAFETY INFORMATION Section 2. Warning and Safety Instructions The MasterTemp ® pool heaters are designed and manufactured to provide many years of safe and reliable service when installed, operated and maintained according to the information in this manual. Throughout the manual, safety warnings a...
Page 6 - Risk of fire or explosion from flammable vapors.; flammable gas may result from incorrect servicing.
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 6 Section 2. Warning and Safety Instructions SAFETY INFORMATION, (cont’d.) WARNING — Risk of fire or explosion from incorrect fuel use or faulty fuel conversion. Do not try to run a heater set up for natural gas on propane gas or vice vers...
Page 7 - GENERAL SPECIFICATIONS; by a solid fence, wall or other permanent barrier.; is a colorless and odorless gas.; factor in reducing carbon monoxide poisoning.
7 GENERAL SPECIFICATIONS NOTICE: • Combustion air contaminated by corrosive chemical fumes can damage the heater and will void the warranty.• The Combination Gas Control Valve on this heater differs from most appliance gas controls. If it must be replaced, for safety reasons replace it only with an ...
Page 8 - Customer Service; Contents; Section 1. Heater Identification Information
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 8 Customer Service 8:00 AM to 8:00 PM Phone: (800) 831-7133 Fax: (800) 284-4151 Visit www.pentair.com Technical Support Sanford, North Carolina (8:00 AM to 8:00 PM ET) Phone: (919) 566-8000 Fax: (919) 566-8920 Moorpark, California (8:00 AM...
Page 9 - Section 7. Replacement Parts
9 Contents ( Continued) Section 4. Operation ................................................................................................................ 42 Basic System Operation .......................................................................................................................
Page 10 - Section 3. Installation Instructions; Section 3: Installation Instructions; HEATER DESCRIPTION; PS; PUTTING THE HEATER INTO SERVICE
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 10 Section 3. Installation Instructions Section 3: Installation Instructions Gas Air Mixer Blower Inlet (Cold Water) Exhaust Heating Coils Outlet (Mixed Water) Burner Figure 1. HEATER DESCRIPTION Figure 1 is a diagram of the heater showing...
Page 11 - Section 3. Installation Instructions; SPECIFICATIONS; TOP
11 Section 3. Installation Instructions These installation instructions are designed for use by qualified personnel only, trained especially for installation of this type of heating equipment and related components. Some states require installation and repair by licensed personnel. If this applies i...
Page 12 - PLUMBING CONNECTIONS; Figure 3 f; WATER CONNECTIONS; ater requires proper water flow and pressure for its; Do not rely on the pressure switch in this case.
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 12 PLUMBING CONNECTIONS The MasterTemp heater has the unique capability of direct schedule 40 PVC plumbing connections. A set of bulkhead fittings is included with the MasterTemp heater to insure conformity with Pentair’s recommended PVC p...
Page 13 - MULTIPLE HEATER INSTALLATION; past end heater inlet; Figure 5. Two MasterTemp® Heaters Plumbing Hydraulic Diagram; Check Valves and Flow Meters; on heater inlets; Balance flow to each heater.; Check Valves and Flow Meters; on heater inlets; Figure 6. Four MasterTemp Heaters Plumbing Hydraulic Diagram
13 All plumbing on multiple heater installations must be done in parallel. See Figure 5 and Figure 6. To prevent heater overheating and to ensure heater longevity, water flow to each heater must be balanced for optimum operation. To meet recommended flow rates, be sure all installed pipes are instal...
Page 14 - VALVES; NOT; sanitize the; the feeder and heater.; lock it in place to avoid tampering. See Figure 7.; MODEL; * Do not exceed the maximum recommended flow; * Pumps 2 HP or larger can produce water pressure
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 14 Section 3. Installation Instructions VALVES When any equipment is located below the surface of the pool or spa, valves should be placed in the circulation piping system to isolate the equipment from the pool or spa. Check valves are rec...
Page 15 - BELOW POOL LEVEL INSTALLATION; service technician. See following; before installation.; BELOW OR ABOVE POOL INSTALLATION; qualified service technician. See page 44, Figure 38; FLOW SWITCH; If the heater is installed more than 5’ above the; ). This in conjunction with an IntelliFlo; Cold Water In
15 BELOW POOL LEVEL INSTALLATION If the heater is below water level, the pressure switch must be adjusted. This adjustment must be done by a qualified service technician. See following CAUTION before installation. CAUTION BELOW OR ABOVE POOL INSTALLATION The water pressure switch is set in the facto...
Page 16 - GAS CONNECTIONS; GAS LINE INSTALLATIONS; National Fuel Gas Code,; Do not use flame to test the gas line.; Use soapy water or another nonflammable method.; NOTE; requirements. Do not use a restrictive gas cock.; FOR NEW HEATER INSTALLATION: SEE NEXT PAGE TO INSTALL; SEDIMENT TRAPS
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 16 GAS CONNECTIONS GAS LINE INSTALLATIONS Before installing the gas line, be sure to check which gas the heater has been designed to burn. This is important because different types of gas require different gas pipe sizes. The rating plate ...
Page 17 - Gas Pipe Escutcheon Installation; removed
17 Section 3. Installation Instructions Gas Pipe Escutcheon Installation Required Parts: P/N 467107, Gas Pipe Escutcheon (PVC), P/N 270114, Phillips Retention Screw (#8) 1. IMPORTANT! Turn off the electrical supply to the heater and turn off the pump. WARNING! Risk of fire or explosion. Never test f...
Page 18 - GAS PIPE SIZING; PIPE SIZING FOR GAS LINE CONNECTIONS; MAXIMUM EQUIVALENT PIPE LENGTH; STAGE TWO “LOW PRESSURE” GAS PIPE SIZING
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 18 GAS PIPE SIZING Table 2. Section 3. Installation Instructions PIPE SIZING FOR GAS LINE CONNECTIONS MAXIMUM EQUIVALENT PIPE LENGTH (Ft.) Natural Gas at 1000 B.T.U. per Cubic Foot Propane Gas at 2500 B.T.U. per Cubic Foot MODEL 1/2” 3/4” ...
Page 19 - Do NOT use an open flame to test; Risk of fire and explosion.; in; required to maintain proper combustion and must NOT be altered.; TESTING GAS PRESSURE
19 Before operating the heater, the heater and its gas connections must be leak tested. Do NOT use an open flame to test for leaks. Test all gas connections for leaks with soapy water or another non-flammable method (see page 16). The heater and its individual shut-off valve must be disconnected fro...
Page 20 - OUTDOOR INSTALLATION LOCATED OUTDOORS, USING THE; Propane is heavier than air. Do not; HEATER CLEARANCES – OUTDOOR; • This unit shall not be operated outdoors at temperatures below -20; DO; recommendations for the heater rating.; GAS PRESSURE REQUIREMENTS; Gas Pressure; Minimum Inlet; Manifold
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 20 OUTDOOR INSTALLATION LOCATED OUTDOORS, USING THE BUILT-IN STACKLESS VENTING SYSTEM. WARNING Risk of explosion if a unit burning propane gas is installed in a pit or other low spot. Propane is heavier than air. Do not install the heater ...
Page 21 - opening into a building.; If installing the heater next to or near an air; VENTING GUIDELINES; SIDE VIEW
21 Section 3. Installation Instructions 3 ft. (1 M) or more Figure 12. For minimum exhaust vent clearances for all building openings, including but not limited to vented eaves, doors, windows, gravity air inlet, see Figure 12, show below. In Canada, the heater must be installed with the top of the v...
Page 22 - INDOOR VENTING —; Vertical only; nonpositive; Vertical or Horizontal; positive; DO NOT; HEATER CLEARANCES; Note; OUTSIDE VENT COVER REMOVAL
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 22 INDOOR VENTING — General Requirements The heater may be installed as a Category I or Category III appliance. Vented Appliance (Category I) – Vertical only An appliance that operates with a nonpositive vent static pressure and with a ven...
Page 23 - Minimum Net Free Open Area for Each Opening*; Model; COMBUSTION AIR SUPPLY; the surrounding area.; Air Supply Requirements Guide for MasterTemp Heaters; Direct Air Intake Duct with 3-inch PVC Pipe (Indoor Installation); Heater is certified
23 Section 3. Installation Instructions Minimum Net Free Open Area for Each Opening* (Square Inches/Centimeters) Model All Air From Inside Building All Air From Outside Building Combustion Vent Combustion Vent 175 200 sq. in. 1290 sq. cm. 200 sq. in. 1290 sq. cm. 50 sq. in. 323 sq. cm. 50 sq. in. 32...
Page 24 - Corrosive Vapors and Possible Causes; Area; New construction and remodel; fumes which can void the warranty.; MUST BE; be purchased separately. See page 63 for parts list.
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 24 Corrosive Vapors and Possible Causes Table 6. Area Likely Contaminants Chlorinated swimming pools and spas Pool or spa cleaning chemicals. Acids, such as hydrochloric or muriatic acid. New construction and remodel - ing areas. Glues and...
Page 25 - VENT INSTALLATION –; • Vent it vertically using Type “B” double wall vent connector pipe.; VERTICAL VENTING; Do not; use a draft hood with this heater.; Metal Flue Collar; on page 26 to determine allowable vent sizes for your heater.
25 VENT INSTALLATION – INDOOR INSTALLATION (US AND CANADA) (Category I) Always vent the heater to the outdoors, see Note*. • Vent it vertically using Type “B” double wall vent connector pipe. Locate the heater so as to minimize the length of horizontal venting and the number of vent elbows required....
Page 26 - Read “VERTICAL VENTING – NEGATIVE PRESSURE” before using this table.
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 26 Type “B” Double-Wall Vent with Type “B” Double-Wall Connector in Feet (Meters) Vent Size Model 175 Height min./max. Model 200 Height min./max. Model 250 Height min./max. Model 300 Height min./max. Model 400 Height min./ max. 6 in. 6 ft....
Page 27 - Install the metal Flue Collar in the Vent Body of the; Continue to next page.
27 WARNING Risk of fire or asphyxiation if vent is not assembled according to manufacturer’s instructions or if vent parts from different manufacturers are mixed. Vent parts from different manufacturers ARE NOT interchangeable. Mixing parts from more than one manufacturer may cause leaks or damage t...
Page 28 - DO NOT USE VINYL OR
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 28 4. Install vent pipe so that it can expand and contract freely as the temperature changes. Support the vent pipe according to applicable codes and the vent manufacturer’s instructions. Pipe support must allow the vent pipe free movement...
Page 29 - HORIZONTAL OR VERTICAL VENTING; Each 90° elbow; Do NOT combine exhaust vent pipes to a common; CONNECTING SPECIAL METALIC GAS VENT TO THE HEATER; requires a four (4) inch special gas approved “Category III”; Flue gases under positive pressure may escape into
29 HORIZONTAL OR VERTICAL VENTING - POSITIVE PRESSURE (See Figures 19, 20, & 21) (Category III) Vent the heater either horizontally or vertically using an optional vent adapter of the 4-inch special gas approved Category III vent pipes. Install the vent pipe in accordance with local codes and th...
Page 30 - Mechanical connections (such as screws) can cause; Attach with manufacturer’s specified adhesive.; manufacturers are mixed.; carefully during assembly and installation.; Vent Termination – Vertical; Continue on next page.
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 30 Outlet Air Opening Inlet Air Opening Chimney or Gas Vent Vent Cap and Riser Furnished by Installer Side Wall Vent Heater Chimney or Gas Vent Vent Cap and Riser Furnished by Installer Side Wall Vent Heater Outlet Air Opening Inlet Air Op...
Page 31 - Vent Termination – Horizontal; , following the vent manufacturer’s instructions; Allow at least three feet (1M) vertical clearance over vent; Avoid corners or alcoves where snow or wind could have
31 Figure 19/20. 1' Min. 4' Min. 4' Min. 4' Min. 4' Min. 3' Minimum clearance ifhorizontal distance toexhaust opening is lessthan 10 feet. Forced AirInlet VentTermination 1' Minimumabove snow orfinished grade(whichever ishigher) At least 7' above grade adjacent to publicwalkways VentTermination Vent...
Page 32 - RAISE AT LEAST; Propane is heavier than air. Do; GARAGE OR UTILITY ROOM INSTALLATION; Combustion air contaminated by corrosive
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 32 Leave 6 in. (15 cm) of clear space between heater and combustible surface. Leave 3 ft. (1 m) or more of clearance above heater RAISE AT LEAST 18 in. (46 cm) above floor to avoid flammable vapors 18 in. WARNING Risk of asphyxiation if ex...
Page 33 - CONTROL PANEL POSITIONING; Rotate the top panel to the desired position located at 90° angles.; FINAL INSTALLATION CHECK; manufacturer’s instructions and code requirements.; ELECTRICAL CONNECTIONS; Note: The heater operating AMP draw is
33 CONTROL PANEL POSITIONING On an outdoor shelter installation, the exhaust discharges into a vent pipe. Orient the heater so that the vent pipe does not interfere with adjustment of the operating controls. The control panel located on the top panel can be rotated to any of the three sides of the h...
Page 34 - approved AWM low energy stranded) copper wire or it’s equivalent.; black; clock controlling the filter pump should have a; AC Plug; AC VOLTAGE SELECT PLUGS:
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 34 ELECTRICAL CONNECTIONS (CONTINUED) NOTE • Before making any electrical connections to the power supply, remove the access door panels, open the control box and plug in the correct plug (120 VAC or 240 VAC). See plugs below. CAUTION The ...
Page 35 - EXHAUST SIDE; HEATER BONDING
35 EXHAUST SIDE ELECTRICALCONDUIT PORT HEATER BONDING CONNECTOR Section 3. Installation Instructions Figure 27. HEATER BONDING WARNING To reduce voltage gradients in the pool area, the heater and the pool system equipment must be electrically grounded and “bonded” together. Con- nect a solid copper ...
Page 36 - REMOTE CONTROL CONNECTIONS; Switch off power to heater at main circuit breaker panel.; To connect a 2-Wire Control (such as IntelliTouch; apply line voltage to control board terminals.; M o v e j u m p e r ( a s s h o w n o n F i g u re 3 4 ) t o; To control heaters that are operated in parallel, connect wiring
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 36 REMOTE CONTROL CONNECTIONS 1. Switch off power to heater at main circuit breaker panel. 2. Unbolt and remove the access door panels. 3. Open control box cover (see Figure 28). 4a. To connect a 2-Wire Control (such as IntelliTouch ® or E...
Page 37 - the hole in the heater’s side panel.; Note: The conduit or cable connector; Note: Do not let the wires contact the; panel using the four corner wing nuts.; Connecting the MasterTemp; • The heater front panel buttons are inactive. Press a
37 Accessing the MasterTemp ® Heater RS-485 COM Port To access the MasterTemp heater control panel RS-485 COM port terminal, the RS-485 cable must be routed through the hole in the heater’s side panel. To route the RS-485 cable through the heater’s panel to the control panel circuit board: 1. Remove...
Page 38 - IntelliCenter Control System Load Center:; Power Center. See wiring connection; To connect the MasterTemp heater to the load center:; BEFORE REMOVING THE HIGH VOLTAGE COVER PANEL FROM THE; Panel and remove the panel.; Front door; Loosen Outdoor Control Panel; Connecting the RS-485 Cable from the Heater to the Load Center
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 38 Note: Use a 22 AWG four conductor low voltage RS-485 cable to connect to the MasterTemp heater to the IntelliCenter Control System Load Center: 4. Run the RS-485 cable from the heater’s control board RS-485 COM port terminal connector t...
Page 39 - SWITCH ON AC power; to the IntelliCenter Control System Load Center.; MasterTemp Heater; Heater to IntelliCenter wires pin assignment; To heater
39 Section 3. Installation Instructions COMMUNICATION PORTS A & B 14 VDC, 2.0A Max. Combined. Connecting IntelliFlo ® Pump to IntelliCenter™ Control System COM PORT: Strip 1/4” insulation from the green and yellow wire conductors.• Connect the Green wire to pin 2 on Connector J4 or J5 . • Connec...
Page 40 - MASTERTEMP HEATER WIRING DIAGRAM; CONNECTION DIAGRAM
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 40 MASTERTEMP HEATER WIRING DIAGRAM (3-WIRE SYSTEM) BR BR VAL TH IND 24 VAC 24 VAC FS BYPASS VALVE JMP1 PS ES1 AFS AGS SFS GRN BLK N/C SPA LINE COMMON LINE POOL LINE J5 J2 J7 J1 OPERATING CONTROL J3 GAS GND THER M IS TOR Plug –12 pin 120V ...
Page 41 - MASTERTEMP HEATER ELECTRICAL SCHEMATIC LADDER DIA-
41 MASTERTEMP HEATER ELECTRICAL SCHEMATIC LADDER DIA- Figure 35. BYPASS VALVE 4.) EXTERNAL VALVE THAT NEEDS TO BE INSTALLED. Section 3. Installation Instructions
Page 42 - BASIC SYSTEM OPERATION; Operation Instructions; FOR YOUR SAFETY: READ BEFORE LIGHTING; START-UP AND OPERATION; MASTERTEMP HEATER HSI ELECTRONIC IGNITION LIGHTING/OPERATION; WHAT TO DO IF YOU SMELL GAS
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 42 BASIC SYSTEM OPERATION Start pump, make sure the pump is running and is primed, to close the water pressure switch and supply power to heater. Be sure the pool and/or spa is properly filled with water. Follow the Lighting/Operating inst...
Page 43 - OPERATING INSTRUCTIONS; Follow “B” in the “Before Start-up” instructions; See CONTROL PANEL; TO TURN OFF GAS TO APPLIANCE; Press the OFF button on operating control.; YOU ARE HERE; Section 4. Operation Instructions
43 OPERATING INSTRUCTIONS 1. STOP! Read the safety information on (page 42). 2. Set both pool and spa set points to the lowest settings. 3. Turn off all electric power to the appliance. 4. This appliance does not have a pilot. It is equipped with an ignition device which automatically lights the bur...
Page 44 - SAFETY CONTROLS; WATER PRESSURE SWITCH; Hazardous pressure. Do not bypass the Water Pressure Switch; NOTE: SEE, BELOW POOL LEVEL INSTALLATION; HIGH LIMITS
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 44 SAFETY CONTROLS AIR FLOW SWITCH (AFS) The air flow switch, (see Figure 38), is a safety device used to insure that the combustion air blower (fan) is operating and has been designed to monitor the vacuum (negative) pressure within the b...
Page 45 - OPERATION OF IGNITION MODULE; The Ignition Module; Diagnostic errors are displayed on; and viewed on Heater menu; ERROR PS MESSAGE; Table 7. Diagnostic Indicator
45 SAFETY CONTROLS, (cont’d.) OPERATION OF IGNITION MODULE The Ignition Module , (see Figure 41), is microprocessor based and operates on 24VAC supplied by the transformer. The control utilizes a microprocessor to continually and safely monitor, analyze, and control the proper operation of the gas f...
Page 46 - Control Panel Description; The LCD displays two lines of text.; Menu Navigation; CONTROL PANEL; Figure 42. Heater Control Panel
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 46 Control Panel Description LCD Display: The LCD displays two lines of text. During normal heater operation the current pool or spa water temperature is shown on line 1 of the display. The heater set point for the pool or spa is shown on ...
Page 47 - Menu; Total number of hours the heater has spent heating the water.; By-pass Valve Description
47 Menu POOL MAX (65°F-104°F): The maximum heater operating temperature for the pool. SPA MAX (65°F-104°F): The maximum heater operating temperature for the spa. UNITS: Select F (Fahrenheit) or C (Celsius) to display change the display of the heat settings. Select US or Metric units. HISTORY: Use Up...
Page 48 - Section 5. Troubleshooting; Troubleshooting; Initial Troubleshooting; READ THE FOLLOWING INFORMATION CAREFULLY; voltage in the heater circuit.; BLACK plug; RED plug; is for; Error and Fault Codes; Table 8. Heater Error and Fault Codes
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 48 Section 5. Troubleshooting Troubleshooting Initial Troubleshooting Only qualified, trained service technicians with appropriate test equipment should service the heater. Remember that all parts of the system affect heater operation. Bef...
Page 49 - Section 5. Troubleshooting; Start here for directions to specific Troubleshooting Chart
49 Section 5. Troubleshooting Troubleshooting Hazardous voltage. Can shock, burn or kill. Disconnect power before servicing any components. Do not jumper switch terminals to remedy a failed safety switch. WARNING WARNING Initial Troubleshooting Only qualified, trained service technicians with approp...
Page 52 - IGN is ON
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 52 Section 5. Troubleshooting IGN is ON Verify connection to HSI igniter, HSI is not broken, flame current status. YES NO Gas flow during ignition andburner fire for less than 7 seconds. Gas flow during ignition try, but burner does not fi...
Page 53 - ERR AFS
53 Diagnostic Alarms: AGS, AFS, HLS, PS, E01 or 126 Do not jumper a safety switch to remedy a failed switch. NOTE: ES1 is a spare and should be jumpered. CAUTION Service pump and filter to restore proper flow. After ser- vicing, verify proper operation of Pressure Switch (PS). Replace thermistor or ...
Page 54 - Diagnostic Alarms: SFS; ERR SFS
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 54 Section 5. Troubleshooting Diagnostic Alarms: SFS NO (HD ) NO (Basic) NO Reset power to Heater and retry. Heater should fire. Does the LCD show ErrorCode “E05” or “E06” ? Heater starts and runs OK, but temperature of exhaust climbs to 4...
Page 56 - CARE AND MAINTENANCE; flammable liquids near heater or in the same room with heater.; PRESSURE RELIEF VALVE; the valve and drain line.; Maintenance; Section 6. Maintenance; Drill through the NPT Port, then
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 56 CARE AND MAINTENANCE WARNING Risk of fire or explosion from flammable vapors. Do not store gasoline, cleaning fluids, varnishes, paints, or other volatile flammable liquids near heater or in the same room with heater. The following main...
Page 57 - Optional Pressure Relief Valve Escutchen:; the round Pressure Relief Valve knock out from the heater panel.; See page 61 for parts list.; Place the water pipe escutcheon over the water pipe,; Tool; : Phillips Screwdriver; Water Pipe Escutcheon Installation; Figure 44. Water Pipe with Escutcheon Installed.
57 Optional Pressure Relief Valve Escutchen: Note: If the heater is equipped with an optional Pressure Relief Valve, use the escutcheon on the Pressure Relief Valve water pipe. If required, before installing the escutcheon, carefully remove the round Pressure Relief Valve knock out from the heater p...
Page 58 - CHECKING WATER FLOW; FOLLOW INSTRUCTIONS UNDER “TO TURN OFF GAS TO THE APPLIANCE” (; SPRING AND FALL OPERATION; (20° C) will cause harmful condensation and will damage; Turn off electrical supply to the heater and pump.; in the outlet pipe to drain the manifold.
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 58 AFTER START-UP CHECKING WATER FLOW WARNING FIRE OR FLOODING HAZARD. IF THE UNIT OVERHEATS AND THE BURNER FAILS TO SHUT OFF, FOLLOW INSTRUCTIONS UNDER “TO TURN OFF GAS TO THE APPLIANCE” ( PAGE 43) , AND CALL A QUALIFIED SERVICE TECHNICIA...
Page 59 - To return the heater to service after winterizing:; Close drain cock and fittings. Before starting the; (See additional notes under Important Notices in Introduction.); MAINTAINING POOL TEMPERATURE; chemicals and reduce load on the filtering system.; CHEMICAL BALANCE; POOL AND SPA WATER; provided you keep your water chemistry in proper condition.; WHAT A DISINFECTANT DOES
59 To return the heater to service after winterizing: Close drain cock and fittings. Before starting the heater, circulate water through the heater for several minutes until all air noises stop. See also “BEFORE START-UP” (page 42) and “CARE AND MAINTENANCE” (page 56) . (See additional notes under I...
Page 60 - If pH is too low (over acid) the following conditions may occur:; Excessive eye burn or skin irritation.; ALKALINITY High or Low:
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 60 CHEMICAL BALANCE, (continued) It is wise to test pool water regularly. Never allow chlorine residual to drop below 0.6 ppm (parts per million). The minimum level for effective chlorine or bromine residual is 1.4 ppm. pH - The term pH re...
Page 61 - MASTERTEMP HEATER REPLACEMENT PARTS; Repair Parts are available from a Pentair dealer.
61 MASTERTEMP HEATER REPLACEMENT PARTS Repair Parts are available from a Pentair dealer. If your dealer cannot supply you, call Customer Support at 1-800-831-7133. Para una lista detallada de lasPiezas del Sistema del Quemador(Números del 5 al 7),ver página 62 Para una lista detallada de lasPiezas d...
Page 62 - For heaters manufactured between; Rodent Resistant Parts List; MASTERTEMP
MASTERTEMP Pool and Spa Heater Installation and User’s Guide 62 Section 7. Replacement Parts For heaters manufactured between 1/12/2009 and 10/31/2013 (clamp lid tub design) Note: Kits also include Clamp Assembly, O-Ring and Silicon Tube (see page 63) Combustion Chamber Gasket Lid Nut/Washer (9x) CL...
Page 63 - REPAIR PARTS – BURNER SYSTEM
63 MASTERTEMP HEATER REPLACEMENT PARTS REPAIR PARTS – BURNER SYSTEM Model Key Part 200NA 300NA 400NA No. Description Qty. 200LP 300LP 400LP 1 Combination Gas Control Valve Kit 42001-0051S 42001-0051S 42001-0051S 2 3/4" Union 1211 11111 1 111111111 1 11111 1 38404-4097S 38404-4097S 38404-4097S 3 ...
Page 65 - REPAIR PARTS – ELECTRICAL SYSTEM
65 MASTERTEMP HEATER REPLACEMENT PARTS Section 7. Replacement Parts 2 6 7 8 9 10 3 4 17 11 13 14 1 5 15 REPAIR PARTS – ELECTRICAL SYSTEM Model Key Part 200/300/400 NA No. Description Qty. 200/300/400 LP 1 Heater Display Cover 1 42002-0035 2 Igniter Bracket 1 42001-0030S 3 Igniter/Igniter Gasket Kit ...