Page 2 - ft; P0 – Sup; ll; Choose among 3 types of attachment; Actual; nts...; COM port: 2nd RS232C interface
Con t ro l F PWIN Pro PLC Progr a mm i ng So ft w a r e c on f orm i ng t o IEC61131-3 2 F P0 – Sup e r Comp a ct PLC In c r e d i b l y Sm a ll , A l on e or Ev e n a s Mu l t i p l e Comb i n e d Un i t s A control unit a mere 25mm* in width. Even expanded to 128 I/O points, the width is still onl...
Page 3 - You S; sy; (Maximum possible expansion is three units); Networking
3 E i th e r 10 Po i nts or th e M a x i mum of 128 Po i nts You S a v e Th i s Mu c h Sp ace ! The expansion unit can be attached easilywithout any cables. The expansion unit can easily be attached directly to the control unit. Special expansion cables, backplanes and so forth are unnecessary as th...
Page 4 - Relay output type
4 F P0 CPU Un i ts A R i c h L i n e -Up o f Bo t h S i ng l e a nd Comb i n e d Un i t s Contro l un i ts A maximum of 3 expansion units can be added to the control unit. (Combining relay output types and transistor output types is also possible. In this event, the maximum number of I/O points when...
Page 5 - ns; li; Thermocouple and RTD units; Input only type
5 Relay output type F P0 Exp a ns i on Un i ts Choos e t h e Numb e r o f I / O Po i n t s t o Su i t t h e App li ca t i on Digital I/O units Analogue I/O units Thermocouple and RTD units Networking units MEWNET-F FP0-IOL (MEWNET-F Slave) S-LINK CPU FP0-SL1 (S-LINK Master) PROFIBUS FP0-DPS2 (DP Sla...
Page 6 - gh Sp; ee
6 F P0 – Impr e ss i v e C a p a b ili t i e s H i gh Sp ec i f i ca t i ons f or Bo t h Sp ee d a nd C a p ac i t y 0.9µs per basic instruction. Pulse catch and interrupt input functions meet the need for high-speed response. L a rg e c a p a c i ty Pu l s e c a tch funct i on Can read pulses as sh...
Page 7 - un
7 F P0 – Impr e ss i v e C a p a b ili t i e s F P0 F un c t i ons Equipped with 2-axis independent positioning and high-speed counter for support of PWM output. Pu l s e output funct i on The unit comes equipped with 2 channels for the output of up to 10kHz pulses (5kHz during 2-channel output). Si...
Page 8 - In
8 F P0 Commun i c a t i on S e r i a l In t e r f ace s a nd Mod e m Comp a t i b l e Progr a mm i ng i nt e rf a c e TOOL port ( a l so for commun i c a t i on) In MEWTOCOL-COM Slave mode, this port offers access to the entire FP0 memory area. For example during data exchange between a host PC runn...
Page 9 - r M
9 F P0 Commun i c a t i on E a s i e r M a i n t e n a n ce Th a n Ev e r B e f or e M a i nt e n a nc e s a v i ng ■ Overwrite function in RUN mode It is possible to overwrite a program while the FP0 is running, such as during program debugging and startup adjustments. ■ Backup battery unnecessary ...
Page 10 - or Cos; ons
10 F P0 PRO F IBUS DP S l a v e or R e mot e I/O Un i t F or Cos t E ff ec t i v e Con t ro l o f D i s t r i bu t e d F i e l d D e v i ce The FP0 DPS2 can operate either as a DP Slave module or as a remote I/O system to which different decentralised inputs and outputs can be connected.A DIP switch...
Page 11 - Space saving; Fea; Controls 64 input points and 64 output points.; Allows simultaneous use of expansion units.; Power supply specification
11 F P0 S-LINK Un i t Conn ec t s D i r ec t l y t o t h e S-LINK f or R e du ce d W i r i ng Wire-saving The use of wires is greatly reduced and the number of connecting ter-minal blocks is minimised, resulting in large reduction in cost, as well as waste generated during wiring. Space saving S-Lin...
Page 12 - Un; wor; FP0-IOL Link Unit Specifications
12 F P0 MEWNET- F Un i t N e t wor k i ng Un i t s The FP0 can be used as a slave station for MEWNET-F (remote I/O system) by adding I/O link unit. MEWNET-F is a reduced-wiring, remote I/O system that connects PLCs located separately and I/O slave stations with 2-core cabling. By adding an I/O link ...
Page 15 - gh Pr; Temperature control; nd
15 F P0 Th e rmocoup l e Input Exp a ns i on Un i ts En a b l e H i gh Pr ec i s i on T e mp e r a t ur e Con t ro l a t Low Cos t The FP0-TC4 and FP0-TC8 thermocouple units are suitable for user-friendly temperature acquisition using standard thermocouples withhigh precision. ■ Up to three units ca...
Page 16 - ec; application areas
16 F P0 RTD Input Exp a ns i on Un i t Us e r F r i e nd l y A c qu i s i t i on o f T e mp e r a t ur e s w i t h H i gh Pr ec i s i on Fea tur e s FP0-RTD66 channels ■ The module can be easily installed in an existing system. Special connection cables, backplanes, and so forth are unnecessary as t...
Page 17 - Sp
17 )TEM $ESCRIPTION 2ATEDOPERATINGVOLTAGE 6$# /PERATINGVOLTAGERANGE TO6$# !LLOWABLENOVOLTAGETIME POINTSPOINTSTYPE MSAT6 MSAT6 POINTSPOINTS3,).+TYPE MSAT66 !MBIENTTEMPERATURE #TO # 3TORAGETEMPERATURE #TO # !MBIENTHUMIDITY TO2(.ONCONDENSING 3TORAGEHUMIDITY TO2(.ONCONDENSING "REAKDOWNVOLTAGE "E...
Page 19 - cc; The most important highlights at a glance:; Free demonstration CD
19 Contro l F PWIN Pro Progr a mm i ng A cc ord i ng t o t h e In t e rn a t i on a l S t a nd a rd IEC 61131-3 FPWIN Pro is the Panasonic programming software developed according to the international standard IEC 61131-3 (for Windows 98, NT V4.0, 2000, ME or XP). This new version is a result of exp...
Page 20 - The FP Web-Server ́s 3 interfaces; gh; RS232C device server:
20 F P W e b-S e rv e r Progr a mm e / Op e r a t e t h e F P0 Us i ng a LAN or WAN N e t wor k The multifunctional FP Web-Server provides users with the option of connecting the FP0 or any other FP Series PLC to the Internet/Intranet thus enabling bi-directional communication. No changes to the PLC...
Page 21 - The connection in ActiveX technology.
21 Contro l CommX , PCWAY , OPC S e rv e r V i su a li s a t i on So ft w a r e f or R ea dy M a d e or Cus t om i s e d So l u t i ons The connection in ActiveX technology. ■ Connects your Visual Basic application to Panasonic PLCs. ■ Gives you the possibility to easily develop highly customised co...
Page 22 - Produ; Expansion units; Control units
22 Notes: • A power cable (order number AFP0581) is enclosed with the control unit and the relay output type expansion units(Transistor output type upgrade units do not require a power cable). • Two Phoenix terminals (9-pin) are needed with the relay output type terminal type. A 2.5mm width screwdri...
Page 24 - iri; AX; Acc; Opt
24 Ter m i n al s c re w d ri v er N e c e ss ar y w h e n w i r i ng re l a y ou t pu t t yp e & t er m i n a l s (P ho e n i x ) . A tt a c h m e n t e x a m p l e W iri ng too l s P ar t s f o r a tt a c h m e nt I / O c a b le s & n e t w o rk s O r d er nu m b er : A F P0806 S li m a tt...
Page 25 - Control FPWIN Pro; Control FPWIN GR
25 Progr a mm i ng Too l s a nd Curr e nt Consumpt i on L i st Produ c t s a nd Ord e r Numb e rs Ver.2.6 Ver.2.6 © 1999-2006 Panasonic Electric Works Europe AG Made in Germany © 1999-2006 Panasonic Electric Works Europe AG Made in Germany Control FPWIN Pro English, German, French, Italian, Spanish,...
Page 26 - Maximum output current:; FP0 Power Supply
26 F P0 S e r i e s Pow e r Supp li e s ■ Small size: - FP0 power supply: 90 x 60 x 30.4mm - FP power supply: 115 x 75 x 42mm ■ Maximum output current: - FP0 power supply: 0.7A (24VDC) - FP power supply: 2.1A (24VDC) ■ Multiple voltage input: 85 to 265VAC ■ Optimal protection: overvoltage, overcurre...
Page 27 - Ord
27 F P0 Product Ov e rv i e w Ord e r Numb e rs Product Name Part Number 1. Control Units FP0-C10RS, 6 Inputs / 4 Outputs (p+n / Relay) FP0-C10RSA FP0-C10CRS, 6 Inputs / 4 Outputs (p+n / Relay), RS232 COM port Interface FP0-C10CRSA FP0-C14RS, 8 Inputs / 6 Outputs (p+n / Relay) FP0-C14RSA FP0-C14CRS,...
Page 28 - As; Global Network; Panasonic Electric Works
16 G l ob a l N e twork S e rv i c e s G l ob a l N e twork S e rv i c e s G l ob a l N e twork S e rv i c e s C o p yr i g h t © 2006 • Pr i n t e d i n G erm a ny 4093 e u e n 09 / 06 As i a P a c i f i c Ch i n a J a p a n North Am e r i c a Europ e Global Network P l ea s e cont a ct our G l ob ...