- Page 2 – NAME OF EACH PART; Remote Control; Indoor Unit; AUTO; HOW TO OPERATE
- Page 3 – SETTING THE TIMER; Powerful Mode
- Page 4 – CARE AND MAINTENANCE; Cleaning the Air Filter; Air Purifying Filters; HELPFUL INFORMATION
- Page 5 – TROUBLESHOOTING; Normal Operation; This is the answer; Call the Dealer Immediately
- Page 6 – 0 Installation Instructions; The items to be followed are classified by the symbols:
9 Operating Instructions
SAFETY PRECAUTIONS
Before operating, please read the following
“Safety Precautions” carefully.
●
To prevent personal injury, injury to others and
property damage, the following instructions must be
followed.
●
Incorrect operation due to failure to follow instructions
will cause harm or damage, the seriousness of which
is classified as follow:
!
Warning
This sign warns of death or serious injury.
!
Caution
This sign warns of damage to property.
●
The instructions to be followed are classified by the
following symbols:
This symbol (with a white background) denotes an
action that is PROHIBITED.
These symbols (with a black background) denote
actions that are COMPULSORY.
OFF
■
Installation Precautions
!
Warning
●
This room air conditioner must be
earthed.
Improper grounding could cause
electric shock.
●
Ensure that the drainage piping is
connected properly.
Otherwise, water will leak out.
●
Do not install the unit in a
potentially explosive atmosphere.
Gas leak near the unit could cause
fire.
●
Do not install, remove and reinstall the unit by
yourself.
Improper installation will cause leakage, electric
shock or fire. Please engage an authorized dealer
or specialist for the installation work.
!
Caution
■
Operation Precautions
!
Warning
This sign warns of death or serious injury.
●
Do not share outlet.
●
Do not insert plug to operate the unit. Do not
pull out plug to stop the unit.
●
Do not operate with wet hands.
●
Do not damage or modify the power cord.
●
Do not insert finger or other objects into the
indoor or outdoor units.
●
Do not expose directly to cold air for a long
period.
●
Plug in properly.
●
Use specified power cord.
●
If abnormal condition (burnt smell, etc.)
occurs, switch off and unplug the power
supply.
!
Caution
This sign warns of injury.
●
Do not pull the cord to disconnect the plug.
●
Do not wash the unit with water.
●
Do not use for other purposes such as
preservation.
●
Do not use any combustible equipment at
airflow direction.
●
Do not sit or place anything on the outdoor
unit.
●
Switch off the power supply before cleaning.
●
Ventilate the room regularly.
●
Pay attention as to whether the installation
rack is damaged after long period of usage.
●
Switch off the power supply if the unit is not
used for a long period.
OFF
OFF
NAME OF EACH PART
■
Indoor Unit
1
Front Panel
2
Air Intake Vent
3
Power Supply Cord
4
Air Outlet Vent
5
Vertical Airflow Direction Louver
6
Horizontal Airflow Direction Louver
(manually adjusted)
7
Indicator Panel
1
Auto Operation Button
(when the front panel is opened)
2
Powerful Mode Indicator
–
ORANGE
3
Ionizer Mode Indicator
–
GREEN
4
Power Indicator
–
GREEN
5
Quiet Mode Indicator
–
ORANGE
6
Timer Mode Indicator
–
ORANGE
●
Indoor Unit
(when the front panel is opened)
1
Front Panel
2
Air Filters
3
Air Purifying Filter
■
Outdoor Unit
1
Air Intake Vents
2
Ground Terminal
(Inside cover)
3
Piping
4
Connecting Cable
5
Drain Hose
6
Air Outlet Vents
■
Accessories
●
Remote Control
●
Remote Control Indication Sticker
●
Remote Control Holder
●
Two RO3 (AAA) dry-cell batteries or equivalent
●
Air Purifying Filter
CH
EC
K
TE
M
P
AU
T
AUT
O
ON
OFF
AU
T
AUT
O
DR
DR
Y F
AN
AN
COO
L
COOL
FA
N
AN
AU
T
AUT
O
RE
SE
T
BAT
TE
RY
CLO
CK
MO
DE
SLE
EP
ECO
NOM
Y
FAN
SPE
ED
AIR
SW
IN
G
OF
F
CAN
CEL
ON
SE
T
Ste
p
1
2
3
TIM
ER
+
HEA
HEA
T
OF
F/O
N
1
2
3
4
5
7 6
2
1
3
1
6
2
3
4
5
1
2 3
6
5
4
(Catechin Air
Purifying Filter)
(Triple Deodorizing
Filter)
32
CS-C7CK P CU-C7 CKP5 / CS-C9 CKP CU-C9 CKP5 / CS-C9 CKP CU-C9 CKP6 / CS-C1 2CKP CU-C1 2CKP 5 / CS-C1 2CKP CU- C12CK P6
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
NAME OF EACH PART ■ Remote Control ● Remote Control Signal. • Make sure it is not obstructed.• Maximum distance : 10 m.• Signal received sound. One short beep or one long beep. ● Notes for Remote Control. • Do not throw or drop.• Do not get it wet.• Certain type of fluorescent lamps may affect signa...
MANUALFive stages of adjustmentcan be made between14° ~ 36°. MANUALFive stages of adjustmentcan be made between0° ~ 61°. Heat Pump Model MANUALFive stages of adjustmentcan be made between14° ~ 36°. Swing up/downAutomatically Move up/downAutomatically MANUALFive stages of adjustmentcan be made betwee...
■ Pre-season Inspection ● Is the discharged air cold/warm? Operation is normal if 15 minutes after the start ofoperation, the difference between the air intake andoutlet vents temperature is:- ● Are the air intake or outlet vents of the indoor oroutdoor units obstructed? ● Are the remote control bat...