FLEXware16 Amp Maximum 30VDC/250VAC
Rated Relay and DIN Mount Base with LED
The FLEXware Relay Assembly will activate a two-wire start generator
when wired to the AUX output of either an OutBack FX Inverter/Charger
or an OutBack Charge Controller. The assembly consists of an LED
module and a relay inserted (in one orientation) into a base. The base is
mounted onto the DIN rail of any OutBack AC industrial control panel.
Relay Features:
Rated current - 16 amps AC/DC 8 amps per terminal
•
Rated voltage - 30VDC/250VAC
•
Coil power draw - 400 mW
•
Gold contacts for use in low power situations
•
A green LED lights to show the relay energizing when proper
•
voltage is applied to the relay coil connectors.
Base accommodates connections for wiring the coil, common relay
•
contacts, normally open relay contacts, and normally closed relay
contacts.
LED
RELAY
BASE
FRONT VIEW
SIDE VIEW
"Loading the manual" means you need to wait until the file loads and becomes available for online reading. Some manuals are very large, and the time they take to appear depends on your internet speed.
Summary
WIRING INSTRUCTIONS Wire the relay coil from the AUX positive and negative connections of your OutBack product according to the diagram. The coil connections (A1 and A2) are not polarity sensitive and the LED will light in either polarity as long as proper voltage is present. (Required voltage is no...
There are two screw terminals for each relay contact. Each can handle up to 8 amps. They are tied together internally. COM 11 and COM 21 are the common relay connections. Either can be used for loads under 8 amps. If the load exceeds 8 amps, use both COM 11 and COM 21. r NO 14 and NO 24 are normally...
European Sales Office C/ Castelló, 17 08830 - Sant Boi de Llobregat BARCELONA, España Phone: +34.93.654.9568 Corporate Office19009 62nd Avenue NEArlington, WA USA(+1) 360-435-6030 900-0018-01-00 REV A www.outbackpower.com